B2004158 B2004158
Explanation
A problem occurred during the IPL of a partition.Response
The partition ID is in extended word one as LP=xxx in decimal format. This error indicates a failure during a search for the load source. It is usual for a number of these failures to occur prior to finding a valid load source. This is normal. Look for SRCs in the Serviceable Event View logged at the time the partition was performing an IPL. If a B2xx3110 error is logged, a B2xx3200 may be posted to the control panel. Work the B2xx3110 error in the Serviceable Event View. If the system IPL hangs at B2xx3200 and you cannot check the SRC history, perform the actions indicated for the B2xx3110 SRC. If there are other SRCs in the Serviceable Event View, then work those errors. If this SRC is posted on the control panel and there are no other SRCs listed in the Serviceable Event View, then perform LICIP15.Problem determination
No action is required.