AIX configuration program progress codes

This section describes the AIX® configuration program codes.

Notes:
  1. All current AIX progress codes are listed below. Many are for hardware that is not used in the DS8000® product. In such cases, contact the next level of support.
  2. Some systems might produce 4-digit codes. If the leftmost digit of a 4-digit code is 0, use the three rightmost digits.

Three-digit AIX configuration program progress codes

This section provides descriptions of the 3-digit numbers and characters that display on the operator panel and descriptions of the location codes used to identify a particular item.

Note: All current 3-digit AIX progress codes are listed below. Many are for hardware that is not used in the DS8000 product. In such cases, call the next level of support.
Table 1. 3-digit AIX configuration program progress codes
Progress code Description/Action
2E6 PCI differential ultra SCSI adapter or the universal PCI differential Ultra SCSI adapter being configured.
2E7 Configuration method unable to determine if SCSI adapter type is SE or DE type.
440 9.1 GB Ultra SCSI disk drive being identified or configured.
441 18.2 GB Ultra SCSI disk drive being identified or configured.
444 2-port multiprotocol PCI adapter (ASIC) being identified or configured.
447 PCI 64-bit Fibre Channel arbitrated loop adapter being configured.
458 36 GB DAT72 tape drive
459 36 GB DAT72 tape drive
500 Querying standard I/O slot.
501 Querying card in slot 1.
502 Querying card in slot 2.
503 Querying card in slot 3.
504 Querying card in slot 4.
505 Querying card in slot 5.
506 Querying card in slot 6.
507 Querying card in slot 7.
508 Querying card in slot 8.
510 Starting device configuration.
511 Device configuration completed.
512 Restoring device configuration files from media.
513 Restoring basic operating system installation files from media.
516 Contacting server during network boot.
517 Mounting client remote file system during network IPL.
518 Remote mount of the root (/) and /usr file systems failed during network boot.
520 Bus configuration running.
521 /etc/init invoked cfgmgr with invalid options; /etc/init has been corrupted or incorrectly modified (irrecoverable error).
522 Configuration manager has been invoked with conflicting options (irrecoverable error).
523 Configuration manager is unable to access the ODM database (irrecoverable error).
524 Configuration manager is unable to access the config.rules object in the ODM database (irrecoverable error).
526 Configuration manager is unable to get data from a customized device driver object in the ODM database (irrecoverable error).
525 Configuration manager is unable to get data from a customized device object in the ODM database (irrecoverable error).
527 Configuration manager was invoked with the phase 1 flag; running phase 1 at this point is not permitted (irrecoverable error).
528 Configuration manager cannot find the sequence rule, or no program name was specified in the ODM database (irrecoverable error).
529 Configuration manager is unable to update ODM data (irrecoverable error).
530 The savebase program returned an error.
531 Configuration manager is unable to access the PdAt object class (irrecoverable error).
532 Not enough memory to continue (malloc failure); irrecoverable error.
533 Configuration manager is unable to find a configuration method for a device.
534 Configuration manager is unable to acquire database lock (irrecoverable error).
535 HIPPI diagnostics interface driver being configured.
536 Configuration manager encountered more than one sequence rule specified in the same phase (irrecoverable error).
537 Configuration manager encountered an error when invoking the program in the sequence rule.
538 Configuration manager is going to invoke a configuration method.
539 Configuration method has ended and control has returned to configuration manager.
541 A DLT tape device is being configured.
549 Console could not be configured for the Copy a System dump menu.
551 IPL vary-on is running.
552 IPL vary-on failed.
553 IPL phase 1 is complete.
554 The boot device could not be opened or read, or unable to define NFS swap device during network boot.
555 An ODM error occurred when trying to vary-on the rootvg, or unable to create an NFS swap device during network boot.
556 Logical volume manager encountered error during IPL vary-on.
557 Root file system does not mount.
558 Not enough memory to continue the system IPL.
559 Less than 2 MB of good memory available to load AIX kernel.
569 FCS SCSI protocol device being configured (32 bits).
570 Virtual SCSI devices being configured.
571 HIPPI common function device driver being configured.
572 HIPPI IPI-3 master transport driver being configured.
573 HIPPI IPI-3 slave transport driver being configured.
574 HIPPI IPI-3 transport services user interface device driver being configured.
575 9570 disk-array driver being configured.
576 Generic async device driver being configured.
577 Generic SCSI device driver being configured.
578 Generic common device driver being configured.
579 Device driver being configured for a generic device.
580 HIPPI TCP/IP network interface driver being configured.
581 Configuring TCP/IP.
582 Configuring Token-Ring data link control.
583 Configuring an Ethernet data link control.
584 Configuring an IEEE Ethernet data link control.
585 Configuring an SDLC MPQP data link control.
586 Configuring a QLLC X.25 data link control.
587 Configuring a NETBIOS.
588 Configuring a bisync read-write (BSCRW).
589 SCSI target mode device being configured.
590 Diskless remote paging device being configured.
591 Configuring an LVM device driver.
592 Configuring an HFT device driver.
593 Configuring SNA device drivers.
594 Asynchronous I/O being defined or configured.
595 X.31 pseudo-device being configured.
596 SNA DLC/LAPE pseudo-device being configured.
597 OCS software being configured.
598 OCS hosts being configured during system reboot.
599 Configuring FDDI data link control.FCS SCSI protocol device being configured (64 bits).
59B FCS SCSI protocol device being configured (64 bits).
5C0 Streams-based hardware drive being configured.
5C1 Streams-based X.25 protocol being configured.
5C3 Streams-based X.25 COMIO emulator driver being configured
5C4 FCS adapter device driver being configured.
5C5 SCB network device driver for FCS being configured.
5C6 AIX SNA channel being configured.
600 Starting network boot portion of /sbin/rc.boot.
602 Configuring network parent devices.
603 /usr/lib/methods/defsys, /usr/lib/methods/cfgsys, or /usr/lib/methods/cfgbus failed.
604 Configuring physical network boot device.
605 Configuration of physical network boot device failed.
606 Running /usr/sbin/ifconfig on logical network boot device.
607 /usr/sbin/ifconfig failed.
608
Attempting to retrieve the client.info file with tftp.

Note: A flashing 608 indicates multiple attempts to retrieve the client_info file are occurring.
609 The client.info file does not exist or it is zero length.
60B 18.2 GB 68-pin LVD SCSI disk drive being configured.
610 Attempting remote mount of NFS file system.
611 Remote mount of the NFS file system failed.
612 Accessing remote files; unconfiguring network boot device.
614 Configuring local paging devices.
615 Configuration of a local paging device failed.
616 Converting from diskless to dataless configuration.
617 Diskless to dataless configuration failed.
618 Configuring remote (NFS) paging devices.
619 Configuration of a remote (NFS) paging device failed.
61B 36.4 GB 80-pin LVD SCSI disk drive being configured.
61D 36.4 GB 80-pin LVD SCSI disk drive being configured.
61E 18.2 GB 68-pin LVD SCSI disk drive being configured.
620 Updating special device files and ODM in permanent file system with data from boot RAM file system.
621 9.1 GB LVD 80-pin SCSI drive being configured.
622 Boot process configuring for operating system installation.
62D 9.1 GB 68-pin LVD SCSI disk drive being configured.
62E 9.1GB 68-pin LVD SCSI disk drive being configured.
636 TURBOWAYS 622 Mbps PCI MMF ATM adapter.
637 Dual channel PCI-2 Ultra2 SCSI adapter being configured.
638 4.5 GB Ultra SCSI single-ended disk drive being configured.
639 9.1 GB 10K RPM Ultra SCSI disk drive (68-pin).
63A See 62D.
63B 9.1 GB 80-pin LVD SCSI disk drive being configured.
63C See 60B.
63D 18.2 GB 80-pin LVD SCSI disk drive being configured.
63E 36.4 GB 68-pin LVD SCSI disk drive being configured.
63F See 61B.
640 9.1 GB 10K RPM Ultra SCSI disk drive (80-pin).
646 High-speed token-ring PCI adapter being configured.
64A See 62E.
64B 9.1 GB 80-pin LVD SCSI disk drive being configured.
64C See 61E.
64D 18.2 GB LVD 80-pin Drive/Carrier being configured.
64E 36.4 GB 68-pin LVD SCSI disk drive being configured.
64F See 61D.
650 SCSD disk drive being configured.
653 18.2 GB Ultra-SCSI 16-bit disk drive being configured.
655 GXT130P graphics adapter being configured.
657 GXT2000P graphics adapter being configured.
658 PCI Fibre Channel disk subsystem controller being identified or configured.
659 2102 Fibre Channel disk subsystem controller drawer being identified or configured.
660 2102 Fibre Channel disk array being identified or configured.
662 Ultra2 integrated SCSI controller.
663 The ARTIC960RxD digital trunk quad PCI adapter or the ARTIC960RxF digital trunk resource adapter being configured.
664 32x (MAX) SCSI-2 CD-ROM drive being configured.
667 PCI 3-Channel Ultra2 SCSI RAID adapter being configured.
669 PCI gigabit Ethernet adapter being configured.
66A Keyboard/mouse attachment card-PCI being configured.
66C 10/100/1000 Base-T Ethernet PCI adapter.
66D PCI 4-channel Ultra-3 SCSI RAID adapter.
66E 4.7 GB DVD-RAM drive.
677 PCI 32-bit Fibre Channel arbitrated loop adapter being configured.
67B PCI cryptographic coprocessor being configured.
682 20x (MAX) SCSI-2 CD-ROM drive being configured.
689 4.5 GB Ultra SCSI single-ended disk drive being configured.
68C 20 GB 4-mm tape drive being configured.
68E POWER® GXT6000P PCI graphics adapter.
690 9.1 GB Ultra SCSI single-ended disk drive being configured.
69b 64-bit/66 MHz PCI ATM 155 MMF PCI adapter being configured.
69d 64-bit/66 MHz PCI ATM 155 UTP PCI adapter being configured.
6CC SSA disk drive being configured.
700 A 1.1 GB 8-bit SCSI disk drive being identified or configured.
701 A 1.1 GB 16-bit SCSI disk drive being identified or configured.
702 A 1.1 GB 16-bit differential SCSI disk drive being identified or configured.
703 A 2.2 GB 8-bit SCSI disk drive being identified or configured.
704 A 2.2 GB 16-bit SCSI disk drive being identified or configured.
705 Configuration method for the 2.2 GB 16-bit differential SCSI disk drive is being run. If an irrecoverable error occurs, the system halts.
706 A 4.5 GB 16-bit SCSI disk drive being identified or configured.
707 A 4.5 GB 16-bit differential SCSI disk drive being identified or configured.
708 An L2 cache being identified or configured.
709 128 port ISA adapter being configured.
710 POWER GXT150M graphics adapter being identified or configured.
711 Unknown adapter being identified or configured.
712 Graphics slot bus configuration is executing.
713 The IBM® ARTIC960 device being configured.
714 A video capture adapter being configured.
715 The Ultramedia Services audio adapter being configured. This number displays briefly on the panel.
717 TP Ethernet adapter being configured.
718 GXT500 graphics adapter being configured.
720 Unknown read/write optical drive type being configured.
721 Unknown disk or SCSI device being identified or configured.
722 Unknown disk being identified or configured.
723 Unknown CD-ROM being identified or configured.
724 Unknown tape drive being identified or configured.
725 Unknown display adapter being identified or configured.
726 Unknown input device being identified or configured.
727 Unknown async device being identified or configured.
728 Parallel printer being identified or configured.
729 Unknown parallel device being identified or configured.
730 Unknown diskette drive being identified or configured.
731 PTY being identified or configured.
732 Unknown SCSI initiator type being configured.
733 7 GB 8-mm tape drive being configured.
734 4x SCSI-2 640 MB CD-ROM drive being configured.
736 Quiet Touch keyboard and speaker cable being configured.
741 1080 MB SCSI disk drive being configured.
745 16 GB 4-mm tape auto loader being configured.
746 SCSI-2 fast/wide PCI adapter being configured.
747 SCSI-2 differential fast/wide PCI adapter being configured.
749 7331 Model 205 tape library being configured.
751 SCSI 32-bit SE F/W RAID adapter being configured.
754 1.1 GB 16-bit SCSI disk drive being configured.
755 2.2 GB 16-bit SCSI disk drive being configured.
756 4.5 GB 16-bit SCSI disk drive being configured.
757 External 13 GB 1.5M/s 1/4-inch tape being configured.
763 SP switch MX adapter being configured.
764 SP system attachment adapter being configured.
772 4.5 GB SCSI F/W disk drive being configured.
773 9.1 GB SCSI F/W disk drive being configured.
774 9.1 GB external SCSI disk drive being configured.
776 PCI token-ring adapter being identified or configured.
777 10/100 Ethernet Tx PCI adapter being identified or configured.
778 POWER GXT3000P 3D PCI graphics adapter being configured.
77B 4-port 10/100 Ethernet Tx PCI adapter being identified or configured.
77c A 1.0 GB 16-bit SCSI disk drive being identified or configured.
783 4-mm DDS-2 tape autoloader being configured.
789 2.6 GB external optical drive being configured.
78B POWER GXT4000P PCI graphics adapter.
78D GXT300P 2D graphics adapter being configured.
790 Multi-bus integrated Ethernet adapter being identified or configured.
797 TURBOWAYS 155 UTP/STP ATM adapter being identified or configured.
798 Video streamer adapter being identified or configured.
799 2-Port multiprotocol PCI adapter being identified or configured.
79c ISA bus configuration executing.
7C0 CPU/system interface being configured.
7C1 Business audio subsystem being identified or configured.
7cc PCMCIA bus configuration executing.
800 TURBOWAYS 155 MMF ATM adapter being identified or configured.
803 7336 tape library robotics being configured.
804 8x speed SCSI-2 CD-ROM drive being configured.
806 POWER GXT800 PCI graphics adapter being configured.
807 SCSI device enclosure being configured.
80c SSA 4-port adapter being identified or configured.
811 CEC enclosure being identified or configured.
812 Memory being identified or configured.
813 Battery for time-of-day, NVRAM, and so on being identified or configured, or system I/O control logic being identified or configured.
814 NVRAM being identified or configured.
815 Floating-point processor test.
816 Operator panel logic being identified or configured.
817 Time-of-day logic being identified or configured.
819 Graphics input device adapter being identified or configured.
821 Standard keyboard adapter being identified or configured.
823 Standard mouse adapter being identified or configured.
824 Standard tablet adapter being identified or configured.
825 Standard speaker adapter being identified or configured.
826 Serial port 1 adapter being identified or configured.
827 Parallel port adapter being identified or configured.
828 Standard diskette adapter being identified or configured.
831 3151 adapter being identified or configured, or serial port 2 being identified or configured.
834 64-port async controller being identified or configured.
835 16-port async concentrator being identified or configured.
836 128-port async controller being identified or configured.
837 16-port remote async node being identified or configured.
838 Network terminal accelerator adapter being identified or configured.
839 7318 serial communications server being configured.
840 PCI single-ended ultra SCSI adapter being configured.
841 8-port async adapter (EIA-232) being identified or configured.
842 8-port async adapter (EIA-422A) being identified or configured.
843 8-port async adapter (MIL-STD-188) being identified or configured.
844 7135 RAIDiant array disk drive subsystem controller being identified or configured.
845 7135 RAIDiant array disk drive subsystem drawer being identified or configured.
846 RAIDiant array SCSI 1.3 GB disk drive being configured.
847 16-port serial adapter (EIA-232) being identified or configured.
848 16-port serial adapter (EIA-422) being identified or configured.
849 X.25 Interface Coprocessor/2 adapter being identified or configured.
850 Token-ring network adapter being identified or configured.
851 T1/J1 Portmaster adapter being identified or configured.
852 Ethernet adapter being identified or configured.
854 3270 Host Connection Program/6000 connection being identified or configured.
855 Portmaster Adapter/A being identified or configured.
857 FSLA adapter being identified or configured.
858 5085/5086/5088 adapter being identified or configured.
859 FDDI adapter being identified or configured.
85c Token-ring high-performance LAN adapter being identified or configured.
861 Optical adapter being identified or configured.
862 Block multiplexer channel adapter being identified or configured.
866 SCSI adapter being identified or configured.
867 Async expansion adapter being identified or configured.
868 SCSI adapter being identified or configured.
869 SCSI adapter being identified or configured.
870 Serial disk drive adapter being identified or configured.
871 Graphics subsystem adapter being identified or configured.
872 Grayscale graphics adapter being identified or configured.
874 Color graphics adapter being identified or configured.
875 Vendor generic communication adapter being configured.
876 8-bit color graphics processor being identified or configured.
877 POWER Gt3/POWER Gt4 being identified or configured.
878 POWER Gt4 graphics processor card being configured.
879 24-bit color graphics card, MEV2 being configured.
880 POWER Gt1 adapter being identified or configured.
887 Integrated Ethernet adapter being identified or configured.
889 SCSI adapter being identified or configured.
890 SCSI-2 differential fast/wide and single-ended fast/wide adapter/A being configured.
891 Vendor SCSI adapter being identified or configured.
892 Vendor display adapter being identified or configured.
893 Vendor LAN adapter being identified or configured.
894 Vendor async/communications adapter being identified or configured.
895 Vendor IEEE 488 adapter being identified or configured.
896 Vendor VME bus adapter being identified or configured.
897 S/370 channel emulator adapter being identified or configured.
898 POWER Gt1x graphics adapter being identified or configured.
899 3490 attached tape drive being identified or configured.
89c A multimedia SCSI CD-ROM being identified or configured.
900 GXT110P graphics adapter being identified or configured.
901 Vendor SCSI device being identified or configured.
902 Vendor display device being identified or configured.
903 Vendor async device being identified or configured.
904 Vendor parallel device being identified or configured.
905 Vendor other device being identified or configured.
908 POWER GXT1000 graphics subsystem being identified or configured.
910 1/4 GB Fiber Channel/266 standard adapter being identified or configured.
911 Fiber Channel/1063 Adapter Short Wave being configured.
912 2.0 GB SCSI-2 differential disk drive being identified or configured.
913 1.0 GB differential disk drive being identified or configured.
914 5 GB 8-mm differential tape drive being identified or configured.
915 4 GB 4-mm tape drive being identified or configured.
916 Non-SCSI vendor tape adapter being identified or configured.
917 A 2.0 GB 16-bit differential SCSI disk drive being identified or configured.
918 A 2.0 GB 16-bit single-ended SCSI disk drive being identified or configured.
920 Bridge box being identified or configured.
921 101 keyboard being identified or configured.
922 102 keyboard being identified or configured.
923 Kanji keyboard being identified or configured.
924 Two-button mouse being identified or configured.
925 Three-button mouse being identified or configured.
926 5083 tablet being identified or configured.
927 5083 tablet being identified or configured.
928 Standard speaker being identified or configured.
929 Dials being identified or configured.
930 Lighted program function keys (LPFK) being identified or configured.
931 IP router being identified or configured.
933 Async planar being identified or configured.
934 Async expansion drawer being identified or configured.
935 3.5-inches diskette drive being identified or configured.
936 5.25-inches diskette drive being identified or configured.
937 An HIPPI adapter being configured.
938 Serial HIPPI PCI adapter being configured.
942 POWER GXT 100 graphics adapter being identified or configured.
943 A 3480 or 3490 control unit attached to a System/370 Channel Emulator/A adapter are being identified or configured.
944 100 MB ATM adapter being identified or configured.
945 1.0 GB SCSI differential disk drive being identified or configured.
946 Serial port 3 adapter being identified or configured.
947 A 730 MB SCSI disk drive being configured.
948 Portable disk drive being identified or configured.
949 Unknown direct bus-attach device being identified or configured.
950 Missing SCSI device being identified or configured.
951 670 MB SCSI disk drive being identified or configured.
952 355 MB SCSI disk drive being identified or configured.
953 320 MB SCSI disk drive being identified or configured.
954 400® MB SCSI disk drive being identified or configured.
955 857 MB SCSI disk drive being identified or configured.
956 670 MB SCSI disk drive electronics card being identified or configured.
957 120 MB DBA disk drive being identified or configured.
958 160 MB DBA disk drive being identified or configured.
959 160 MB SCSI disk drive being identified or configured.
960 1.37 GB SCSI disk drive being identified or configured.
964 Internal 20 GB 8-mm tape drive identified or configured.
968 1.0 GB SCSI disk drive being identified or configured.
970 Half-inch, 9-track tape drive being identified or configured.
971 150 MB 1/4-inch tape drive being identified or configured.
972 2.3 GB 8-mm SCSI tape drive being identified or configured.
973 Other SCSI tape drive being identified or configured.
974 CD-ROM drive being identified or configured.
975 An optical disk drive being identified or configured.
977 M-Audio capture and playback adapter being identified or configured.
981 540 MB SCSI-2 single-ended disk drive being identified or configured.
984 1 GB 8-bit disk drive being identified or configured.
985 M-Video capture adapter being identified or configured.
986 2.4 GB SCSI disk drive being identified or configured.
987 An enhanced SCSI CD-ROM drive being identified or configured.
989 200 MB SCSI disk drive being identified or configured.
990 2.0 GB SCSI-2 single-ended disk drive being identified or configured.
991 525 MB 1/4-inch cartridge tape drive being identified or configured.
994 5 GB 8-mm tape drive being identified or configured.
995 1.2GB 1/4-inch cartridge tape drive being identified or configured.
996 A single-port, multiprotocol communications adapter being identified or configured.
997 FDDI adapter being identified or configured.
998 2.0 GB 4-mm tape drive being identified or configured.
999 7137 or 3514 disk array subsystem being configured.
D46 Token-ring cable.
D81 T2 Ethernet adapter being configured.

Four-digit AIX configuration program progress codes

Some systems might produce 4-digit codes. Table 2 provides descriptions of the 4-digit numbers and characters that display on the operator panel and descriptions of the location codes used to identify a particular item.

Notes:
  1. All current 4-digit AIX progress codes are listed below. Many are for hardware that is not used in the DS8000 product. In such cases, contact the next level of support.
  2. If the leftmost digit of a 4-digit code is 0, use the three rightmost digits and refer to Table 1.
Table 2. 4-digit AIX configuration program progress codes
Progress code Description/Action
2001 Dynamic LPAR CPU removal.
2002 Dynamic LPAR memory addition.
2003 Dynamic LPAR memory removal.
2004 DLPAR maximum memory size too large.
2010 HTX miscompare.
2011 Configuring device model 2107 fcp.
2012 Configuring device model 2107 iscsi.
2013 Configuring MR-1750 (device model 1750) fcp.
2014 Configuring MR-1750 (device model 1750) iscsi.
2015 Configuring SVC (device model 2145) fcp.
2016 Configuring SVCCISCO (device model 2062) fcp.
2017 Configuring SVCCISCO (device model 2062) iscsi.
2018 Configuring virtual management channel driver.
2019 Configuring vty server.
201b Configuring virtual SCSI optical.
2020 Configuring Infiniband ICM kernel component.
2021 Configuring TCP Infiniband interface kernel component.
2512 Configuring PCI-X DDR quad channel Ultra320 SCSI RAID adapter.
2513 Configuring PCI-X DDR quad channel Ultra320 SCSI RAID adapter.
2514 Configuring PCI-X DDR quad channel Ultra320 SCSI RAID adapter.
2520 PCI dual-channel Ultra-3 SCSI adapter being identified or configured.
2522 PCI-X dual-channel Ultra320 SCSI adapter.
2523 PCI-X Ultra320 SCSI RAID adapter.
2526 PCI-X Ultra320 SCSI RAID battery pack.
2527 PCI-X quad-channel U320 SCSI RAID adapter.
2528 PCI-X dual-channel Ultra320 SCSI adapter.
2529 PCI-X dual-channel Ultra320 SCSI RAID adapter.
252B PCI-X DDR dual-channel Ultra320 SCSI RAID adapter.
252D PCI-X DDR dual-channel Ultra320 SCSI RAID adapter.
2530 10/100 Mbps Ethernet PCI Adapter II being configured.
2535 4-Port 10/100/1000 Base-TX Ethernet PCI-X adapter being configured.
2547 Generic 522 bites per sector SCSI JBOD (not osdisk) disk drive.
254E Fibre Channel expansion card.
2562 Keyboard/mouse attachment card-PCI being configured.
2564 Keyboard/mouse attachment card-PCI being configured.
2566 USB 3.5 inches micro diskette drive.
2568 USB CD-ROM, generic.
2571 2-Port PCI asynchronous EIA-232 adapter.
2581 1 GB iSCSI TOE PCI-X adapter is being configured (copper connector).
2582 iSCSI protocol device associated with an iSCSI adapter being configured.
2583 1 GB iSCSI TOE PCI-X adapter being configured (copper connector).
2590 IDE CD-ROM drive.
2591 IDE DVD-ROM drive being configured.
2592 IDE DVD-ROM drive being configured.
2593 IDE DVD-ROM drive being configured.
25A0 I/O planar control logic for IDE devices.
25B9 Ethernet adapter (fiber).
25C2 Dual-port gigabit SX Ethernet PCI-X adapter.
25C3 10/100/1000 Base-TX dual-port PCI-adapter.
25C4 Broadcom dual-port Gpbs Ethernet PCI-X adapter.
25F8 Ethernet adapter (copper).
2600 PCI 64-bit Fibre Channel arbitrated loop adapter being configured.
2601 PCI 64-bit Fibre Channel arbitrated loop adapter being configured.
2631 Integrated IDE controller.
2640 IDE disk drive, 2.5 inches.
2D01 PCI-X quad channel U320 SCSI RAID battery pack.