(B3xxxxxx) Connection monitoring reference codes

These error codes indicate a problem in the connection monitoring between the management console (HMC) and a partition that is running on the managed system. The HMC posts these error codes in the error log in Service Focal Point, but does not report them to the operating systems running on the managed system.

Use the following links to display the appropriate B3xxxxxx reference code table:

If you do not find an SRC in the table that follows, contact your next level of support for assistance.
Notes:
  1. The SRCs on this page are from the Power Systems hardware documentation, and the Descriptions apply to a single CEC enclosure or I/O enclosure. The Action and Failing Item fields are modified as appropriate for DS8000® architecture and repair methods.
  2. SRCs missing from the following tables might be found on the Power Systems online documentation. You can use the SRC description as is to define the problem. Do not use the Action and Failing Item without contacting the next level of support first.
  3. To display the Power Systems hardware online documentation, go to the Web site http://www-01.ibm.com/support/knowledgecenter/.
    • In the IBM Systems Hardware Information right content pane, click POWER6 reference codes listing.
Table 1. (B301xxxx) Connection monitoring reference codes
SRC Description/Action Failing item
B3010001 Management console (HMC) or partition connection monitoring fault. NEXTLVL
B3010002

HMC or partition connection monitoring fault.

Perform the following steps:

  1. Verify the network between the HMC and the partition by pinging in both directions. Correct any problems that you detect.
  2. Reboot the HMC.
PTNNTWK
B3010004

HMC or partition connection monitoring fault

NEXTLVL
B3010012, B3010013, B3010019, B3010020, B3010023, B3010025, B3010026 HMC or partition connection monitoring fault. NEXTLVL
B3010027 HMC or partition connection monitoring fault. NEXTLVL
B3010029, B301002B, B301002C, B301002D HMC or partition connection monitoring fault. NEXTLVL
Table 2. (B302xxxx) Connection monitoring reference codes
SRC Description/Action Failing item
B3020001 Management console (HMC) or partition connection monitoring fault. NEXTLVL
Table 3. (B303xxxx) Connection monitoring reference codes
SRC Description/Action Failing item
B3030001 The communication link between the service processor and the management console (HMC) failed.

FSPSP33

SPNETWK

B3030002 A single partition HMC link failed.

FSPSP33

SPNETWK

PTNNTWK

B3030003 Multiple partition HMC links failed.

FSPSP33

SPNETWK

PTNNTWK

B3030004 All partition links for a single system to HMC failed.

FSPSP33

SPNETWK

PTNNTWK

B3030005 All system links from one system to a single HMC failed.

FSPSP33

SPNETWK

B3030006 The links between a single HMC and a single managed system failed.

FSPSP33

SPNETWK

B3030007 A single HMC link to more than one managed system occurred.

FSPSP33

SPNETWK

HMCNTWK

B3030008 One HMC link to another single HMC failed.

FSPSP33

SPNETWK

HMCNTWK

B3030009 One HMC link to more than one HMC occurred.

FSPSP33

SPNETWK

HMCNTWK

B303000A The HMC lost links to all managed systems.

FSPSP33

SPNETWK

B303000B Multiple HMCs lost links to a single managed system.

FSPSP33

SPNETWK

B303000C Multiple HMCs lost links to multiple managed systems.

FSPSP33

SPNETWK

B303000D Multiple HMCs lost links to multiple managed systems.

FSPSP33

SPNETWK

HMCNTWK

B303000E The network interface card (NIC) failed.

Use the error codes offered in the HMC Service Focal Point to diagnose and repair the problem. For more information, see MAP1210 Displaying and repairing a serviceable event.

SYSNTWK
B303000F A single partition HMC link failure occurred on a redundant path.

FSPSP33

SPNETWK

PTNNTWK

B3030010 A single HMC link to one HMC failure occurred on a redundant path.  
B3030011 Server firmware connection monitoring to the flexible service processor failed.

FSPSP33

SPNETWK

B3030012 Flexible service processor connection monitoring of server firmware failed.

FSPSP33

SPNETWK

B3030013 The communication path (mailbox) between server firmware and the flexible service processor failed.

FSPSP33

SPNETWK

MAILBOX

B3031000 Customer reported a console problem when creating a serviceable event on the HMC user interface.

Contact the customer for more information about the problem.

 
B3031001 Customer reported a power problem when creating a serviceable event on the HMC user interface.

Contact the customer for more information about the problem.

 
B3031002 Customer reported a processor problem when creating a serviceable event on the HMC user interface.

Contact the customer for more information about the problem.

 
B3031003 Customer reported a LAN problem when creating a serviceable event on the HMC user interface.

Contact the customer for more information about the problem.

 
B3031004 Customer reported a software problem when creating a serviceable event on the HMC user interface.

Contact the customer for more information about the problem.

 
B3031005 Customer reported a input/output (I/O) problem when creating a serviceable event on the HMC user interface.

Contact the customer for more information about the problem.

 
B3031006 Customer reported a problem when creating a serviceable event on the HMC user interface.

Contact the customer for more information about the problem.

 
B3031007 Customer tested problem reporting by creating a serviceable event on the HMC user interface.

Contact the customer for more information about the problem.

 
B3031100 Customer reported a problem when creating a serviceable event on the HMC user interface.

Contact the customer for more information about the problem.

 
B3031101 Customer reported a power problem when creating a serviceable event on the HMC user interface.

Contact the customer for more information about the problem.

 
B3031102 Customer reported a processor problem when creating a serviceable event on the HMC user interface.

Contact the customer for more information about the problem.

 
B3031103 Customer reported a LAN problem when creating a serviceable event on the HMC user interface.

Contact the customer for more information about the problem.

 
B3031104 Customer reported a software problem when creating a serviceable event on the HMC user interface.

Contact the customer for more information about the problem.

 
B3031105 Customer reported a input/output (I/O) problem when creating a serviceable event on the HMC user interface.

Contact the customer for more information about the problem.

 
B3031106 Customer reported a problem when creating a serviceable event on the HMC user interface.

Contact the customer for more information about the problem.

 
B3031107 Customer tested problem reporting by creating a serviceable event on the HMC user interface.

Contact the customer for more information about the problem.

 
B3036601 The HMC failed to retrieve a platform system dump from the managed system. If you have a redundant HMC environment, a peer HMC might have retrieved the dump. This might be a temporary problem.
After receiving this error, perform the following steps:
  1. Use the manage dumps utility to determine if a dump of that type has been received from the managed system.
  2. If you have a peer HMC managing the same system, also check that HMC. Managed System Dumps can be retrieved by any HMC connected to the system. If there is a current dump of the type that failed from the managed system reported in the error, than the available dump of that type has been retrieved.
 
B3036602 The HMC failed to retrieve a dump from the service processor. If you have a redundant HMC environment, a peer HMC might have retrieved the dump. This might be a temporary problem.
After receiving this error, perform the following steps:
  1. Use the manage dumps utility to determine if a dump of that type has been received from the managed system.
  2. If you have a peer HMC managing the same system, also check that HMC. Managed System Dumps can be retrieved by any HMC connected to the system. If there is a current dump of the type that failed from the managed system reported in the error, than the available dump of that type has been retrieved.
 
B3036604 The HMC failed to retrieve a power subsystem dump from the managed system. If you have a redundant HMC environment, a peer HMC might have retrieved the dump. This might be a temporary problem.
After receiving this error, perform the following steps:
  1. Use the manage dumps utility to determine if a dump of that type has been received from the managed system.
  2. If you have a peer HMC managing the same system, also check that HMC. Managed System Dumps can be retrieved by any HMC connected to the system. If there is a current dump of the type that failed from the managed system reported in the error, than the available dump of that type has been retrieved.
 
B3036620 Primary HMC arbitration failure for domain {0} with peers {1}. Servicer Response:
Note: Note: Domain indicates which domain the managed system belongs to. Peers indicate what HMC are also connected to the service processor.
After receiving this error, perform the following steps:

This error code indicates that this HMC did receive primary information from a peer HMC. To resolve this issue ensure that there is connectivity to the service processor and the other HMC connected to the managed system.

 
B3036625 Primary HMC arbitration failure for domain {0} with peers {1}.
Note: Domain indicates which domain the managed system belongs to. Peers indicate what HMC are also connected to the service processor.

After receiving this error, perform the following steps: T

his error code indicates that this HMC could not communicate with the service processor to either set itself as a primary or to determine if other HMCs are connected. To resolve this issue ensure that there is connectivity to the service processor and the other HMC connected to the managed system.

 
Table 4. (B31xxxxx) Connection monitoring reference codes
SRC Description/Action
Perform all actions before exchanging failing items
Failing item
B3100500, B3112420 Ethernet network failure.

Do the following:

  1. Reseat your Ethernet card.
  2. Check your Ethernet cable connections.
  3. If the previous actions do not resolve the problem, contact your next level of support.
NEXTLVL