(B3xxxxxx) Connection monitoring reference codes
These error codes indicate a problem in the connection monitoring between the management console (HMC) and a partition that is running on the managed system. The HMC posts these error codes in the error log in Service Focal Point, but does not report them to the operating systems running on the managed system.
Use the following links to display the appropriate B3xxxxxx reference code table:
- The SRCs on this page are from the Power Systems hardware documentation, and the Descriptions apply to a single CEC enclosure or I/O enclosure. The Action and Failing Item fields are modified as appropriate for DS8000® architecture and repair methods.
- SRCs missing from the following tables might be found on the Power Systems online documentation. You can use the SRC description
as is
to define the problem. Do not use the Action and Failing Item without contacting the next level of support first. - To display the Power Systems hardware
online documentation, go to the Web site http://www-01.ibm.com/support/knowledgecenter/.
- In the IBM Systems Hardware Information right content pane, click POWER6 reference codes listing.
| SRC | Description/Action | Failing item |
|---|---|---|
| B3010001 | Management console (HMC) or partition connection monitoring fault. | NEXTLVL |
| B3010002 | HMC or partition connection monitoring fault. Perform the following steps:
|
PTNNTWK |
| B3010004 | HMC or partition connection monitoring fault |
NEXTLVL |
| B3010012, B3010013, B3010019, B3010020, B3010023, B3010025, B3010026 | HMC or partition connection monitoring fault. | NEXTLVL |
| B3010027 | HMC or partition connection monitoring fault. | NEXTLVL |
| B3010029, B301002B, B301002C, B301002D | HMC or partition connection monitoring fault. | NEXTLVL |
| SRC | Description/Action | Failing item |
|---|---|---|
| B3020001 | Management console (HMC) or partition connection monitoring fault. | NEXTLVL |
| SRC | Description/Action | Failing item |
|---|---|---|
| B3030001 | The communication link between the service processor and the management console (HMC) failed. | |
| B3030002 | A single partition HMC link failed. | |
| B3030003 | Multiple partition HMC links failed. | |
| B3030004 | All partition links for a single system to HMC failed. | |
| B3030005 | All system links from one system to a single HMC failed. | |
| B3030006 | The links between a single HMC and a single managed system failed. | |
| B3030007 | A single HMC link to more than one managed system occurred. | |
| B3030008 | One HMC link to another single HMC failed. | |
| B3030009 | One HMC link to more than one HMC occurred. | |
| B303000A | The HMC lost links to all managed systems. | |
| B303000B | Multiple HMCs lost links to a single managed system. | |
| B303000C | Multiple HMCs lost links to multiple managed systems. | |
| B303000D | Multiple HMCs lost links to multiple managed systems. | |
| B303000E | The network interface card (NIC) failed. Use the error codes offered in the HMC Service Focal Point to diagnose and repair the problem. For more information, see MAP1210 Displaying and repairing a serviceable event. |
SYSNTWK |
| B303000F | A single partition HMC link failure occurred on a redundant path. | |
| B3030010 | A single HMC link to one HMC failure occurred on a redundant path. | |
| B3030011 | Server firmware connection monitoring to the flexible service processor failed. | |
| B3030012 | Flexible service processor connection monitoring of server firmware failed. | |
| B3030013 | The communication path (mailbox) between server firmware and the flexible service processor failed. | |
| B3031000 | Customer reported a console problem when
creating a serviceable event on the HMC user interface. Contact the customer for more information about the problem. |
|
| B3031001 | Customer reported a power problem when creating
a serviceable event on the HMC user interface. Contact the customer for more information about the problem. |
|
| B3031002 | Customer reported a processor problem when
creating a serviceable event on the HMC user interface. Contact the customer for more information about the problem. |
|
| B3031003 | Customer reported a LAN problem when creating
a serviceable event on the HMC user interface. Contact the customer for more information about the problem. |
|
| B3031004 | Customer reported a software problem when
creating a serviceable event on the HMC user interface. Contact the customer for more information about the problem. |
|
| B3031005 | Customer reported a input/output (I/O) problem
when creating a serviceable event on the HMC user interface. Contact the customer for more information about the problem. |
|
| B3031006 | Customer reported a problem when creating
a serviceable event on the HMC user interface. Contact the customer for more information about the problem. |
|
| B3031007 | Customer tested problem reporting by creating
a serviceable event on the HMC user interface. Contact the customer for more information about the problem. |
|
| B3031100 | Customer reported a problem when creating
a serviceable event on the HMC user interface. Contact the customer for more information about the problem. |
|
| B3031101 | Customer reported a power problem when creating
a serviceable event on the HMC user interface. Contact the customer for more information about the problem. |
|
| B3031102 | Customer reported a processor problem when
creating a serviceable event on the HMC user interface. Contact the customer for more information about the problem. |
|
| B3031103 | Customer reported a LAN problem when creating
a serviceable event on the HMC user interface. Contact the customer for more information about the problem. |
|
| B3031104 | Customer reported a software problem when
creating a serviceable event on the HMC user interface. Contact the customer for more information about the problem. |
|
| B3031105 | Customer reported a input/output (I/O) problem
when creating a serviceable event on the HMC user interface. Contact the customer for more information about the problem. |
|
| B3031106 | Customer reported a problem when creating
a serviceable event on the HMC user interface. Contact the customer for more information about the problem. |
|
| B3031107 | Customer tested problem reporting by creating
a serviceable event on the HMC user interface. Contact the customer for more information about the problem. |
|
| B3036601 | The HMC failed to retrieve a platform system
dump from the managed system. If you have a redundant HMC environment,
a peer HMC might have retrieved the dump. This might be a temporary
problem. After receiving this error, perform the following steps:
|
|
| B3036602 | The HMC failed to retrieve a dump from the
service processor. If you have a redundant HMC environment, a peer
HMC might have retrieved the dump. This might be a temporary problem. After
receiving this error, perform the following steps:
|
|
| B3036604 | The HMC failed to retrieve a power subsystem
dump from the managed system. If you have a redundant HMC environment,
a peer HMC might have retrieved the dump. This might be a temporary
problem. After receiving this error, perform the following steps:
|
|
| B3036620 | Primary HMC arbitration failure for domain
{0} with peers {1}. Servicer Response:
Note: Note: Domain indicates which domain the managed system belongs
to. Peers indicate what HMC are also connected to the service processor.
After
receiving this error, perform the following steps: This error code indicates that this HMC did receive primary information from a peer HMC. To resolve this issue ensure that there is connectivity to the service processor and the other HMC connected to the managed system. |
|
| B3036625 | Primary HMC arbitration failure for domain
{0} with peers {1}.
Note: Domain indicates which domain the managed system belongs to.
Peers indicate what HMC are also connected to the service processor.
After receiving this error, perform the following steps: T his error code indicates that this HMC could not communicate with the service processor to either set itself as a primary or to determine if other HMCs are connected. To resolve this issue ensure that there is connectivity to the service processor and the other HMC connected to the managed system. |
| SRC | Description/Action Perform all actions before exchanging failing items
|
Failing item |
|---|---|---|
| B3100500, B3112420 | Ethernet network failure. Do the following:
|
NEXTLVL |