The C2xxxxxx progress codes indicate the progress of a partition IPL that is controlled by the virtual service processor. The virtual service processor can start a variety of operating systems, and some codes below do not apply to the IPL path of a particular operating system. The virtual service processor progress codes end after the environment setup completes and the specific operating system code continues the IPL.
| Progress Code | Description/Action |
|---|---|
| C2001xxx | Early IPL Initialization Phase |
| C2001000 | Partition auto-IPL during a platform IPL |
| C2001010 | IPL source |
| C2001100 | Adding partition resources to the secondary configuration |
| C20011FF | Partition resources added successfully |
| C2001200 | Checking if IPL is allowed |
| C20012FF | Partition IPL is allowed to proceed |
| C2001300 | Initializing ISL roadmap |
| C20013FF | ISL roadmap initialized successfully |
| C2001400 | Initializing SP™ Communication Area #1 |
| C2001410 | Initializing IPL parms |
| C20014FF | IPL parms initialized successfully |
| C2002xxx | SPCN Tower Power On Phase |
| C2002100 | Power on SPCN racks |
| C2002110 | Issuing a rack power on command |
| C200211F | Rack power on command successful |
| C20021FF | SPCN rack power on phase complete |
| C2002200 | Begin acquiring slot locks |
| C20022FF | End acquiring slot locks |
| C2002300 | Begin acquiring VIO slot locks |
| C20023FF | End acquiring VIO slot locks |
| C2002400 | Begin powering on slots |
| C2002450 | Waiting for power on of slots to complete |
| C20024FF | End powering on slots |
| C2002500 | Begin power on VIO slots |
| C20025FF | End powering on VIO slots |
| C2003xxx | Bus Unit ISL Phase |
| C2003100 | Validating ISL command parameters |
| C2003111 | Waiting for Bus object to become operational |
| C2003112 | Waiting for bus unit to become disabled |
| C2003115 | Waiting for creation of bus object |
| C2003150 | Sending ISL command to bus unit |
| C20031FF | Waiting for ISL command completion |
| C20032FF | ISL command complete successfully |
| C2003300 | Start SoftPOR of a failed ISL slot |
| C2003350 | Waiting for SoftPOR of a failed ISL slot |
| C20033FF | Finish SoftPOR of a failed ISL slot |
| C2004xxx | Load Source Device Connection Phase |
| C2004100 | Waiting for load source device to enlist |
| C2004200 | Load source device has enlisted |
| C2004300 | Preparing connection to load source device |
| C20043FF | Load source device is connected |
| C2005xxx | Main Store Dump Phase |
| C2005100 | Preparing to initiate MSD phase |
| C2005110 | Loading SID 82 from load source device |
| C2005115 | MSD Phase I |
| C2005120 | Writing processor registers into SID 82 |
| C2005125 | MSD Phase II |
| C2005130 | Writing mainstore pages to the load source device |
| C2005133 | Writing hardware page table to the load source device |
| C2005135 | MSD Phase III |
| C2005140 | Storing (final) SID 82 back to the load source device |
| C2005150 | Allocating the hardware page table |
| C20051FF | MSD processing complete |
| C2006xxx | Load System Licensed Internal Code from Load Source Phase |
| C2006000 | Locating First LID information on the loadsource |
| C2006005 | Clearing all partition main store |
| C2006010 | Locating Next LID information on the loadsource |
| C2006020 | Verifying LID information |
| C2006030 | Priming LP Configuration LID |
| C2006040 | Preparing to initiate LID load from loadsource |
| C2006050 | LP Configuration LID primed successfully |
| C2006060 | Waiting for LID load to complete |
| C2006100 | LID load completed successfully |
| C2006200 | Loading raw kernel memory image |
| C20062FF | Loading raw kernel memory image completed successfully |
| C2007xxx | Load Source Device Disconnection Phase |
| C2007100 | Disconnecting from load source device |
| C2007103 | Removing load source device from LID Manager object |
| C2007105 | Preparing to remove the load source IP from the primary partition |
| C2007110 | Preparing to remove the load source IOP from the primary partition |
| C2007120 | Non-load source IOP has been successfully removed from the primary partition |
| C2007125 | Load source IOP has been successfully removed from the primary partition |
| C2007130 | Calling fatal error on the Transport Manager bus unit object |
| C20071FF | Load source is successfully disconnected |
| C2008xxx | Start Processors Phase |
| C2008040 | Begin transfer slot locks to partition |
| C2008060 | End transfer slot locks to partition |
| C2008080 | Begin transfer VIO slot locks to partition |
| C20080A0 | End transfer VIO slot locks to partition |
| C20080FF | Hypervisor low level session manager object is ready |
| C2008100 | Initializing SP Communication Area #2 |
| C2008104 | Loading data structures into mainstore |
| C2008110 | Initializing event paths |
| C2008120 | Starting processors |
| C2008130 | Begin associate of serial ports |
| C2008138 | Associating serial ports to the RPA partition |
| C200813F | End associate of serial ports |
| C20081FF | Processors started successfully, now waiting to receive the continue acknowledgement from System Licensed Internal Code |
| C2008200 | Continue acknowledgement received from System Licensed Internal Code |
| C20082FF | VSP IPL complete successfully |