CEC enclosure part numbers, Models 981, 985, 986
| CEC enclosure part name | Figure |
|---|---|
| Cables (external) | Figure 3 |
| Control panel | Figure 1 |
| Disk drive | Figure 1 |
| Disk drive backplane | Figure 2 |
| Ethernet adapter | Figure 3 |
| Fan | Figure 2 |
| I2C interface card assembly | Figure 3 |
| Memory module | Figure 2 |
| PCIe two-port card | Figure 3 |
| Power supply | Figure 3 |
| Processor module | Figure 2 |
| RS-485 serial interface card | Figure 3 |
| SAS RAID internal adapter | Figure 2 |
| System backplane | Figure 2 |
| Card time-of-day battery | Figure 2 |
| Vital product data (VPD) card | Figure 2 |

| Location code | Part name | CCIN (see note) |
Part number |
|---|---|---|---|
| Un-D1 | Control panel assembly | 00E1966 | |
| Un-P1-T5 Un-P1-T6 |
Not used | ||
| Un-P2-D1 to D12 | CEC enclosure disk drive, 300 GB 15 K (512 block size) | 59E0 | 02YC612 |
| Un-P2-D1 to D12 | Disk drive, 300 GB 15 K (528 block size) Contact your next level of support before ordering this drive. 02YC612 is the preferred FRU. |
59E0 | 00E9912 |
| Un-P2-D27 | Not used | ||
|
Important: Read this entire note as there are exceptions to what part number to order.
The custom card identification number (CCIN) identifies the physical features and logical behavior
of a part. If two parts appear physically identical but have different CCINs, they are not
interchangeable unless stated elsewhere in the maintenance package or by the next level of support.
If two parts have different part numbers and yet have the same CCIN, they are interchangeable.
When you order a part number reported in a serviceable event or call home record, check whether the parts-ordering system has a conditional substitute for DS8000®. There are some exceptions where the part number on the DS8000 FRU part number is not the same one that is reported and called home. The part number that is reported and called home might be the original eServer™ part number that might have firmware that is not appropriate for DS8000. Order the DS8000 FRU part number to ensure that the correct firmware is present. |
|||

| Location code | Part name | CCIN (see note 1) |
Part number |
|---|---|---|---|
| Un-A1 Un-A2 Un-A3 Un-A4 |
80 mm fan assembly | 00FV629 | |
| Un-P1 | System backplane (8286-42A) (see
note) (can be used at any DS8000 LIC bundle level) |
2CD4 | 98Y8725 01LT918 |
| Un-P1 | System backplane (8286-42A) (see note) (requires DS8000 LIC bundle level 88.20.112.0 or later) |
2CD4 | 02AR652 |
| Un-P1-C13 | Vital product data (VPD) card (8286-42A) (see note) | 561F | 98Y6788 |
| Un-P1-C14 | SAS RAID internal adapter | 57D7 | 00MH964 |
| Un-P1-C14-P1 Un-P1-C14-P2 |
CEC enclosure disk drive backplane SAS signal cable (short) | 00RR483 | |
| Un-P1-C15 | Card filler (SAS RAID) | 00FW232 | |
| Un-P1-C16 through Un-P1-C31 |
Memory module filler | 00FW989 | |
| Un-P1-C16 through Un-P1-C31 |
Memory module, 32 GB, 1600 MHz DDR3 | 31E9 (note 2) | 00VK195 |
| Memory module, 32 GB, 1600 MHz DDR4 CDIMM | 31ED (note 2) | 00VK296 | |
| Un-P1-C16 through Un-P1-C31 |
Memory module, 64 GB, 1600 MHz DDR3 | 31EA (note 2) | 00VK197 |
| Memory module, 64 GB, 1600 MHz DDR4 CDIMM | 31EE (note 2) | 00VK306 | |
| Un-P1-C32 Un-P1-C33 |
Processor module FRU kit, 3.72 GHz, 8-core (8286-42A) (Kit includes processor module and replacement tools. Module cannot be ordered separately.) | 54E0 | 00FX557 |
| Un-P1-C32 Un-P1-C33 |
Processor module FRU kit, 3.52 GHz, 12-core (8286-42A) (Kit includes processor module and replacement tools. Module cannot be ordered separately.) | 54E3 | 00FX516 |
| Un-P1-C32 Un-P1-C33 |
Processor module heat sink FRU kit (Kit includes heat sink and indium pad) | 00E8868 | |
| Un-P1-E1 | Time-of-day battery | 74Y9628 | |
| Un-P2 | Disk drive backplane | 2B09 | 00E1945 |
|
Note 1: Important: Read this entire note as there are exceptions to
what part number to order. The custom card identification number (CCIN) identifies the physical
features and logical behavior of a part. If two parts appear physically identical but have different
CCINs, they are not interchangeable unless stated elsewhere in the maintenance package or by the
next level of support. If two parts have different part numbers and yet have the same CCIN, they are
interchangeable.
When you order a part number reported in a serviceable event or call home record, check if the parts-ordering system has a conditional substitute for DS8000. There are some exceptions where the part number on the DS8000 FRU part number is not the same one that is reported and called home. The part number that is reported and called home might be the original eServer part number that might have firmware that is not appropriate for DS8000. Order the DS8000 FRU part number to ensure that the correct firmware is present. Note 2: Replace like-for-like. Do not mix DDR3 and DDR4 memory.
Note 3: System backplane and VPD card
are storage-unique parts. Do not use the server version.
|
|||

| Location code | Part name | CCIN | Part number |
|---|---|---|---|
| Un-E1 Un-E2 Un-E3 Un-E4 |
Power supply 900 W | 2B1D | 00RR365 |
| Un-P1-C3 Un-P1-C5 Un-P1-C6 Un-P1-C7 |
PCIe two-port card | 2DD4 | 98Y7945 |
| Un-P1-C8 | I2C interface card assembly | 2DD3 | 98Y9138 |
| Un-P1-C10 | Ethernet adapter (1 Gb four-port, FC 5899) | 576F | 00RX893 |
| Un-P1-C11 | Ethernet adapter (10 Gb and 1 Gb four-port, FC EN0M ) | 2CC0 | 00E3504 |
| Un-P1-C12 | RS-485 serial interface card | 2DDD | 98Y2609 |
| Un-P1-C1 Un-P1-C2 Un-P1-C4 Un-P1-C9 |
Not used | ||
| Un-P1-T1 Un-P1-T2 |
Not used | ||
| Un-P1-T3 Un-P1-T4 |
Ethernet ports (part of Un-P1) |
| Location code | Part name | Part number |
|---|---|---|
| Un-P1-C3-T1 Un-P1-C3-T2 Un-P1-C5-T1 Un-P1-C5-T2 Un-P1-C6-T1 Un-P1-C6-T2 Un-P1-C7-T1 Un-P1-C7-T2 |
PCI cable FRUs, Models 981, 985, 986, 98E, 85E, 86E | See Figure 4 and Table 7. |
| Un-P1-C8-T1 | RPC card to CEC enclosure I2C cable (RPC-1 to upper CEC) | 00YM692 |
| RPC card to CEC enclosure I2C cable (RPC-1 to lower CEC) | 00YM693 | |
| Un-P1-C8-T2 | RPC card to CEC enclosure I2C cable (RPC-2 to upper CEC) | 00YM694 |
| RPC card to CEC enclosure I2C cable (RPC-2 to lower CEC) | 00YM695 | |
| Un-P1-C10-T1 | Ethernet cable (SW1 to upper CEC XC1 LPAR, black) | 00YM686 |
| Ethernet cable (SW1 to lower CEC XC2 LPAR, black) | 00YM687 | |
| Un-P1-C10-T2 | Ethernet cable (SW2 to upper CEC XC1 LPAR, gray) | 00YM690 |
| Ethernet cable (SW2 to lower CEC XC2 LPAR, gray) | 00YM691 | |
| Un-P1-C12-T1 | RPC card to CEC enclosure serial cable (RPC-1 to upper CEC) | 00YM696 |
| RPC card to CEC enclosure serial cable (RPC-1 to lower CEC) | 00YM697 | |
| Un-P1-C12-T2 | RPC card to CEC enclosure serial cable (RPC-2 to upper CEC) | 00YM698 |
| RPC card to CEC enclosure serial cable (RPC-2 to lower CEC) | 00YM699 | |
| Un-P1-T3 | Ethernet cable (SW1 to upper CEC XC1 system backplane, black) | 00YM684 |
| Ethernet cable (SW1 to lower CEC XC2 system backplane, black) | 00YM685 | |
| Un-P1-T4 | Ethernet cable (SW2 to upper CEC XC1 system backplane, gray) | 00YM688 |
| Ethernet cable (SW2 to lower CEC XC2 system backplane, gray) | 00YM689 |
| Location code | Part name | Part number |
|---|---|---|
| Un-P1-C3-T1 Un-P1-C3-T2 Un-P1-C5-T1 Un-P1-C5-T2 Un-P1-C6-T1 Un-P1-C6-T2 Un-P1-C7-T1 Un-P1-C7-T2 |
PCI cable FRUs, Models 981, 985, 986, 98E, 85E, 86E | See Figure 4 and Table 7. |
| Un-P1-C8-T1 | RPC card to CEC enclosure I2C cable (RPC-1 to upper CEC) | 98Y8837 |
| RPC card to CEC enclosure I2C cable (RPC-1 to lower CEC) | 98Y8838 | |
| Un-P1-C8-T2 | RPC card to CEC enclosure I2C cable (RPC-2 to upper CEC) | 98Y8839 |
| RPC card to CEC enclosure I2C cable (RPC-2 to lower CEC) | 98Y8840 | |
| Un-P1-C10-T1 | Ethernet cable (SW1 to upper CEC XC1 LPAR, black) | 98Y8831 |
| Ethernet cable (SW1 to lower CEC XC2 LPAR, black) | 98Y8832 | |
| Un-P1-C10-T2 | Ethernet cable (SW2 to upper CEC XC1 LPAR, gray) | 98Y8835 |
| Ethernet cable (SW2 to lower CEC XC2 LPAR, gray) | 98Y8836 | |
| Un-P1-C12-T1 | RPC card to CEC enclosure serial cable (RPC-1 to upper CEC) | 98Y8841 |
| RPC card to CEC enclosure serial cable (RPC-1 to lower CEC) | 98Y8842 | |
| Un-P1-C12-T2 | RPC card to CEC enclosure serial cable (RPC-2 to upper CEC) | 98Y8843 |
| RPC card to CEC enclosure serial cable (RPC-2 to lower CEC) | 98Y8844 | |
| Un-P1-T3 | Ethernet cable (SW1 to upper CEC XC1 system backplane, black) | 98Y8829 |
| Ethernet cable (SW1 to lower CEC XC2 system backplane, black) | 98Y8830 | |
| Un-P1-T4 | Ethernet cable (SW2 to upper CEC XC1 system backplane, gray) | 98Y8833 |
| Ethernet cable (SW2 to lower CEC XC2 system backplane, gray) | 98Y8834 |

| From CEC R1-XC1 | To Rack 1 I/O Enclosure | Cable FRU part number |
|---|---|---|
| R1-XC1-P1-C6-T1 | (1B1) R1-XI1-P1-C7-T1 | 00YM656 |
| R1-XC1-P1-C6-T2 | (1B2) R1-XI2-P1-C7-T1 | 00YM656 |
| R1-XC1-P1-C7-T1 | (1B3) R1-XI3-P1-C7-T1 | 00YM656 |
| R1-XC1-P1-C7-T2 | (1B4) R1-XI4-P1-C7-T1 | 00YM656 |
| From CEC R1-XC1 | To Rack 2 I/O Enclosure | Cable FRU part number |
| R1-XC1-P1-C3-T1 | (2B1) R2-XI1-P1-C7-T1 | 00YM656 |
| R1-XC1-P1-C3-T2 | (2B2) R2-XI2-P1-C7-T1 | 00YM656 |
| R1-XC1-P1-C5-T1 | (2B3) R2-XI3-P1-C7-T1 | 00YM656 |
| R1-XC1-P1-C5-T2 | (2B4) R2-XI4-P1-C7-T1 | 00YM656 |
| From CEC R1-XC2 | To Rack 1 I/O Enclosure | Cable FRU part number |
| R1-XC2-P1-C6-T1 | (1B1) R1-XI1-P1-C7-T2 | 00YM656 |
| R1-XC2-P1-C6-T2 | (1B2) R1-XI2-P1-C7-T2 | 00YM656 |
| R1-XC2-P1-C7-T1 | (1B3) R1-XI3-P1-C7-T2 | 00YM656 |
| R1-XC2-P1-C7-T2 | (1B4) R1-XI4-P1-C7-T2 | 00YM656 |
| From CEC R1-XC2 | To Rack 2 I/O Enclosure | Cable FRU part number |
| R1-XC2-P1-C3-T1 | (2B1) R2-XI1-P1-C7-T2 | 00YM656 |
| R1-XC2-P1-C3-T2 | (2B2) R2-XI2-P1-C7-T2 | 00YM656 |
| R1-XC2-P1-C5-T1 | (2B3) R2-XI3-P1-C7-T2 | 00YM656 |
| R1-XC2-P1-C5-T2 | (2B4) R2-XI4-P1-C7-T2 | 00YM656 |