CEC enclosure part numbers, Models 981, 985, 986

Information about CEC enclosure parts is listed. Use Table 1 as a directory.
Note: The following part numbers are the most recent for this version of the Parts Catalog. Your storage facility or serviceable event FRU list might contain an older or newer part number. The parts-ordering system recognizes all valid part numbers and automatically substitutes an available part number as needed.
Table 1. Start here, CEC enclosure parts (Models 981, 985, 986)
CEC enclosure part name Figure
Cables (external) Figure 3
Control panel Figure 1
Disk drive Figure 1
Disk drive backplane Figure 2
Ethernet adapter Figure 3
Fan Figure 2
I2C interface card assembly Figure 3
Memory module Figure 2
PCIe two-port card Figure 3
Power supply Figure 3
Processor module Figure 2
RS-485 serial interface card Figure 3
SAS RAID internal adapter Figure 2
System backplane Figure 2
Card time-of-day battery Figure 2
Vital product data (VPD) card Figure 2
Figure 1. CEC enclosure location codes (front view) (Models 981, 985, 986)
POWER8 front view of CEC enclosure location codes
Table 2. CEC enclosure parts (front view) (Models 981, 985, 986)
Location code Part name CCIN
(see note)
Part number
Un-D1 Control panel assembly   00E1966
Un-P1-T5
Un-P1-T6
Not used    
Un-P2-D1 to D12 CEC enclosure disk drive, 300 GB 15 K (512 block size) 59E0 02YC612
Un-P2-D1 to D12 Disk drive, 300 GB 15 K (528 block size)
Contact your next level of support before ordering this drive.

02YC612 is the preferred FRU.
59E0 00E9912
Un-P2-D27 Not used    
Important: Read this entire note as there are exceptions to what part number to order. The custom card identification number (CCIN) identifies the physical features and logical behavior of a part. If two parts appear physically identical but have different CCINs, they are not interchangeable unless stated elsewhere in the maintenance package or by the next level of support. If two parts have different part numbers and yet have the same CCIN, they are interchangeable.

When you order a part number reported in a serviceable event or call home record, check whether the parts-ordering system has a conditional substitute for DS8000®. There are some exceptions where the part number on the DS8000 FRU part number is not the same one that is reported and called home. The part number that is reported and called home might be the original eServer™ part number that might have firmware that is not appropriate for DS8000. Order the DS8000 FRU part number to ensure that the correct firmware is present.

Figure 2. CEC enclosure location codes (top view) (Models 981, 985, 986)
CEC enclosure location codes (top), Model 981
Table 3. CEC enclosure parts (top view) (Models 981, 985, 986)
Location code Part name CCIN
(see note 1)
Part number
Un-A1
Un-A2
Un-A3
Un-A4
80 mm fan assembly   00FV629
Un-P1 System backplane (8286-42A) (see note)
(can be used at any DS8000 LIC bundle level)
2CD4 98Y8725
01LT918
Un-P1 System backplane (8286-42A) (see note)
(requires DS8000 LIC bundle level 88.20.112.0 or later)
2CD4 02AR652
Un-P1-C13 Vital product data (VPD) card (8286-42A) (see note) 561F 98Y6788
Un-P1-C14 SAS RAID internal adapter 57D7 00MH964
Un-P1-C14-P1
Un-P1-C14-P2
CEC enclosure disk drive backplane SAS signal cable (short)   00RR483
Un-P1-C15 Card filler (SAS RAID)   00FW232
Un-P1-C16
through
Un-P1-C31
Memory module filler   00FW989
Un-P1-C16
through
Un-P1-C31
Memory module, 32 GB, 1600 MHz DDR3 31E9 (note 2) 00VK195
Memory module, 32 GB, 1600 MHz DDR4 CDIMM 31ED (note 2) 00VK296
Un-P1-C16
through
Un-P1-C31
Memory module, 64 GB, 1600 MHz DDR3 31EA (note 2) 00VK197
Memory module, 64 GB, 1600 MHz DDR4 CDIMM 31EE (note 2) 00VK306
Un-P1-C32
Un-P1-C33
Processor module FRU kit, 3.72 GHz, 8-core (8286-42A) (Kit includes processor module and replacement tools. Module cannot be ordered separately.) 54E0 00FX557
Un-P1-C32
Un-P1-C33
Processor module FRU kit, 3.52 GHz, 12-core (8286-42A) (Kit includes processor module and replacement tools. Module cannot be ordered separately.) 54E3 00FX516
Un-P1-C32
Un-P1-C33
Processor module heat sink FRU kit (Kit includes heat sink and indium pad)   00E8868
Un-P1-E1 Time-of-day battery   74Y9628
Un-P2 Disk drive backplane 2B09 00E1945
Note 1: Important: Read this entire note as there are exceptions to what part number to order. The custom card identification number (CCIN) identifies the physical features and logical behavior of a part. If two parts appear physically identical but have different CCINs, they are not interchangeable unless stated elsewhere in the maintenance package or by the next level of support. If two parts have different part numbers and yet have the same CCIN, they are interchangeable.

When you order a part number reported in a serviceable event or call home record, check if the parts-ordering system has a conditional substitute for DS8000. There are some exceptions where the part number on the DS8000 FRU part number is not the same one that is reported and called home. The part number that is reported and called home might be the original eServer part number that might have firmware that is not appropriate for DS8000. Order the DS8000 FRU part number to ensure that the correct firmware is present.

Note 2: Replace like-for-like. Do not mix DDR3 and DDR4 memory.
Note 3: System backplane and VPD card are storage-unique parts. Do not use the server version.
Figure 3. CEC enclosure location codes (rear view) (Models 981, 985, 986)
CEC enclosure location codes (rear view)
Table 4. CEC enclosure parts (rear) (Models 981, 985, 986)
Location code Part name CCIN Part number
Un-E1
Un-E2
Un-E3
Un-E4
Power supply 900 W 2B1D 00RR365
Un-P1-C3
Un-P1-C5
Un-P1-C6
Un-P1-C7
PCIe two-port card 2DD4 98Y7945
Un-P1-C8 I2C interface card assembly 2DD3 98Y9138
Un-P1-C10 Ethernet adapter (1 Gb four-port, FC 5899) 576F 00RX893
Un-P1-C11 Ethernet adapter (10 Gb and 1 Gb four-port, FC EN0M ) 2CC0 00E3504
Un-P1-C12 RS-485 serial interface card 2DDD 98Y2609
Un-P1-C1
Un-P1-C2
Un-P1-C4
Un-P1-C9
Not used    
Un-P1-T1
Un-P1-T2
Not used    
Un-P1-T3
Un-P1-T4
Ethernet ports (part of Un-P1)    
Table 5. CEC enclosure cables (rear view) (Models 981, 985) (single-phase).
Note: For three-phase Models 981, 986, see Table 6.
Location code Part name Part number
Un-P1-C3-T1
Un-P1-C3-T2
Un-P1-C5-T1
Un-P1-C5-T2
Un-P1-C6-T1
Un-P1-C6-T2
Un-P1-C7-T1
Un-P1-C7-T2
PCI cable FRUs, Models 981, 985, 986, 98E, 85E, 86E See Figure 4 and Table 7.
Un-P1-C8-T1 RPC card to CEC enclosure I2C cable (RPC-1 to upper CEC) 00YM692
RPC card to CEC enclosure I2C cable (RPC-1 to lower CEC) 00YM693
Un-P1-C8-T2 RPC card to CEC enclosure I2C cable (RPC-2 to upper CEC) 00YM694
RPC card to CEC enclosure I2C cable (RPC-2 to lower CEC) 00YM695
Un-P1-C10-T1 Ethernet cable (SW1 to upper CEC XC1 LPAR, black) 00YM686
Ethernet cable (SW1 to lower CEC XC2 LPAR, black) 00YM687
Un-P1-C10-T2 Ethernet cable (SW2 to upper CEC XC1 LPAR, gray) 00YM690
Ethernet cable (SW2 to lower CEC XC2 LPAR, gray) 00YM691
Un-P1-C12-T1 RPC card to CEC enclosure serial cable (RPC-1 to upper CEC) 00YM696
RPC card to CEC enclosure serial cable (RPC-1 to lower CEC) 00YM697
Un-P1-C12-T2 RPC card to CEC enclosure serial cable (RPC-2 to upper CEC) 00YM698
RPC card to CEC enclosure serial cable (RPC-2 to lower CEC) 00YM699
Un-P1-T3 Ethernet cable (SW1 to upper CEC XC1 system backplane, black) 00YM684
Ethernet cable (SW1 to lower CEC XC2 system backplane, black) 00YM685
Un-P1-T4 Ethernet cable (SW2 to upper CEC XC1 system backplane, gray) 00YM688
Ethernet cable (SW2 to lower CEC XC2 system backplane, gray) 00YM689
Table 6. CEC enclosure cables (rear view) (Models 981, 986) (three-phase).
Note: For single-phase Models 981, 985, see Table 5.
Location code Part name Part number
Un-P1-C3-T1
Un-P1-C3-T2
Un-P1-C5-T1
Un-P1-C5-T2
Un-P1-C6-T1
Un-P1-C6-T2
Un-P1-C7-T1
Un-P1-C7-T2
PCI cable FRUs, Models 981, 985, 986, 98E, 85E, 86E See Figure 4 and Table 7.
Un-P1-C8-T1 RPC card to CEC enclosure I2C cable (RPC-1 to upper CEC) 98Y8837
RPC card to CEC enclosure I2C cable (RPC-1 to lower CEC) 98Y8838
Un-P1-C8-T2 RPC card to CEC enclosure I2C cable (RPC-2 to upper CEC) 98Y8839
RPC card to CEC enclosure I2C cable (RPC-2 to lower CEC) 98Y8840
Un-P1-C10-T1 Ethernet cable (SW1 to upper CEC XC1 LPAR, black) 98Y8831
Ethernet cable (SW1 to lower CEC XC2 LPAR, black) 98Y8832
Un-P1-C10-T2 Ethernet cable (SW2 to upper CEC XC1 LPAR, gray) 98Y8835
Ethernet cable (SW2 to lower CEC XC2 LPAR, gray) 98Y8836
Un-P1-C12-T1 RPC card to CEC enclosure serial cable (RPC-1 to upper CEC) 98Y8841
RPC card to CEC enclosure serial cable (RPC-1 to lower CEC) 98Y8842
Un-P1-C12-T2 RPC card to CEC enclosure serial cable (RPC-2 to upper CEC) 98Y8843
RPC card to CEC enclosure serial cable (RPC-2 to lower CEC) 98Y8844
Un-P1-T3 Ethernet cable (SW1 to upper CEC XC1 system backplane, black) 98Y8829
Ethernet cable (SW1 to lower CEC XC2 system backplane, black) 98Y8830
Un-P1-T4 Ethernet cable (SW2 to upper CEC XC1 system backplane, gray) 98Y8833
Ethernet cable (SW2 to lower CEC XC2 system backplane, gray) 98Y8834
Figure 4. PCIe cables, Models 981, 985, 986, 98E, 85E, 86E
PCIe cables, Models 981, 985, 986, 98E, 85E, 86E
Table 7. PCIe Cabling (Models 981, 985, 986, 98E, 85E, 86E)
From CEC R1-XC1 To Rack 1 I/O Enclosure Cable FRU part number
R1-XC1-P1-C6-T1 (1B1) R1-XI1-P1-C7-T1 00YM656
R1-XC1-P1-C6-T2 (1B2) R1-XI2-P1-C7-T1 00YM656
R1-XC1-P1-C7-T1 (1B3) R1-XI3-P1-C7-T1 00YM656
R1-XC1-P1-C7-T2 (1B4) R1-XI4-P1-C7-T1 00YM656
From CEC R1-XC1 To Rack 2 I/O Enclosure Cable FRU part number
R1-XC1-P1-C3-T1 (2B1) R2-XI1-P1-C7-T1 00YM656
R1-XC1-P1-C3-T2 (2B2) R2-XI2-P1-C7-T1 00YM656
R1-XC1-P1-C5-T1 (2B3) R2-XI3-P1-C7-T1 00YM656
R1-XC1-P1-C5-T2 (2B4) R2-XI4-P1-C7-T1 00YM656
From CEC R1-XC2 To Rack 1 I/O Enclosure Cable FRU part number
R1-XC2-P1-C6-T1 (1B1) R1-XI1-P1-C7-T2 00YM656
R1-XC2-P1-C6-T2 (1B2) R1-XI2-P1-C7-T2 00YM656
R1-XC2-P1-C7-T1 (1B3) R1-XI3-P1-C7-T2 00YM656
R1-XC2-P1-C7-T2 (1B4) R1-XI4-P1-C7-T2 00YM656
From CEC R1-XC2 To Rack 2 I/O Enclosure Cable FRU part number
R1-XC2-P1-C3-T1 (2B1) R2-XI1-P1-C7-T2 00YM656
R1-XC2-P1-C3-T2 (2B2) R2-XI2-P1-C7-T2 00YM656
R1-XC2-P1-C5-T1 (2B3) R2-XI3-P1-C7-T2 00YM656
R1-XC2-P1-C5-T2 (2B4) R2-XI4-P1-C7-T2 00YM656