Extending all racks to full height and installing expansion racks
To install a system that has both extension hardware and expansion racks, the racks are first extended to full height and then fastened together.
About this task
The following lists the sequence to extend the racks and fasten together.
- Use the extension hardware to extend all racks to full height (for models with rack extension hardware).
- Use the merge kit (sometimes called a
marriage kit
) to fasten any expansion racks to the first rack (for systems with multiple racks). - Continue with the installation.
Procedure
-
If you are installing a storage facility that has one or more expansion racks, check now to see
whether the expansion racks have EMI seals on the left side of each rack. Record your results.
Note: The EMI seals are 4 mm wide metallic strips that are attached to the side of the rack near the front, rear, top, and bottom edges.
- _____ Expansion racks have EMI seals.
- _____ Expansion racks do not have EMI seals.
-
Are you installing a storage facility (with or without expansion racks) with rack extension
hardware?
- Yes. Go to Extending all racks to full height.
- No. Go to step 3.
-
Does the storage facility that you are installing have one or more expansion racks?
- Yes, go to Installing expansion racks.
- No, there are no expansion racks. Go to Preparing to check the storage facility and customer power.
The following tables provide a summary of the hardware that is used to extend a rack to full height (extension kit) and to fasten two racks together (merge kit).
The part numbers are subject to change.
Table 1 and Table 2 list the hardware that is used in an extension kit. Table 3 lists the hardware that is used in a rack merge kit for expansion racks without preinstalled EMI seals. Table 4 lists the hardware that is used in a rack merge kit for expansion racks with EMI seals.Table 1. Extension kit (mechanical bracing) Part Part number Purpose Found in Top cover screw (M10, long hex head)
00YM643 Secure top cover to extension panel (if used) or to base frame Top cover of rack as shipped Extension panel screw (M10 x 30)
98Y6729 or equivalent Secure extension panel to base frame Ship group (extension kit) Front right 6U extension panel 98Y7486 EIA rail and mechanical bracing Ship group (extension kit) Rear right 6U extension panel (left side when viewed from rear)
98Y7487 EIA rail and mechanical bracing Ship group (extension kit) Front left 6U extension panel 98Y7329 EIA rail and mechanical bracing Ship group (extension kit) Front left 6U extension panel 02AM766 EIA rail and mechanical bracing, with EMI seals (used on expansion racks with EMI seals)
Ship group (extension kit) Rear left 6U extension panel (right side when viewed from rear)
98Y7330 EIA rail and mechanical bracing Ship group (extension kit) Rear left 6U extension panel (right side when viewed from rear)
02AM767 EIA rail and mechanical bracing, with EMI seals (used on expansion racks with EMI seals)
Ship group (extension kit) Socket, 12 mm deep (1/4 inch drive) 98Y8397 Loosen and tighten top cover screws Ship group (extension kit) Table 2. Extension kit (side covers and rails) Part Part number Purpose Found in Screw, M4 x 10 15R9571 Secure 6U extensions to front and rear door Ship group (extension kit) Screw, M4 x 10 15R9571 Secure 6U side extension cover to rack Ship group (extension kit) Extension panel 6U side cover 98Y6945 Cover side of rack with 6U extension Ship group (extension kit) Screw, M5 x 16 23R1521 Secure storage enclosure rails to frame Ship group (extension kit) Nut clip, M5 74F1823 Secure storage enclosure rails to frame Ship group (extension kit) Screw, M5 x 16 23R1521 Secure storage enclosure to rails Ship group (extension kit) Table 3. Rack merge kit (expansion racks without preinstalled EMI seals) Part Part number Purpose Found in Right vertical trim with EMI gasket, 40U front and rear 00YM625 (note 3.a) EMI shield between racks (mounted on right wall of rack) Ship group (merge kit) Right vertical trim with EMI gasket, 6U front and rear 00YM628 EMI shield between racks (mounted on right wall of 6U extension) Ship group (merge kit for 6U extension) Right horizontal trim with EMI gasket, top and bottom 00YM626 (note 3.b) EMI shield between racks (mounted on right wall of rack) Ship group (merge kit) Left vertical trim (no EMI gasket), 40U front and rear 00YM627 (note 3.c) EMI shield between racks (mounted on left wall of rack) Ship group (merge kit) Left vertical trim (no EMI gasket), 6U front and rear 00YM629 EMI shield between racks (mounted on left wall of 6U extension) Ship group (merge kit for 6U extension) Screw, M4 x 10 15R9571 Secure EMI trim to racks Ship group (merge kit) Screw, M10 x 30 98Y6729 Fasten racks together Ship group (merge kit) Washer, M10 41U8933 Fasten racks together Ship group (merge kit) Notes:- A two-piece trim kit (00YM947 and 00YM948, or equivalent) might be substituted for 00YM625.
- A two-piece trim kit (00YM951 and 00YM952, or equivalent) might be substituted for 00YM626.
- A two-piece trim kit (00YM949 and 00YM950, or equivalent) might be substituted for 00YM627.
Table 4. Rack merge kit (expansion racks with EMI seals) Part Part number Purpose Found in Screw, M10 x 30 98Y6729 Fasten racks together Ship group (merge kit) Washer, M10 41U8933 Fasten racks together Ship group (merge kit) Note: Expansion racks with EMI seals do not require a separate trim kit for EMI shielding.