FC-AL cables - Models 951, 95E (business class)

Use the point-to-point cabling diagrams below to route the FC-AL cables on a Model 951, with or without expansion racks.

  1. Racks are shown with the maximum number of storage enclosures and device adapter cards. Your rack might contain fewer storage enclosures or device adapter cards.
  2. The figures that follow show the maximum number of racks in a storage facility with these rack models.
  3. FC-AL cables and connectors are identified with two different color codes and a location designator:
    1. A colored band, corresponding to the color code of the DA pair, is found on each end of the cable near the connector. These color codes are shown in Figure 2.
    2. The connector itself is color coded to help prevent cross-cabling at the Fibre Channel interface card (FCIC) or device adapter card (DA) end. The connectors will always appear in the following order:
      beige (T1), green (T2), black (T3), and blue (T4)	
      as shown in Figure 3 and Figure 4. This color code is specific to each FCIC or DA, and is independent of the DA pair color code.
    3. A black or white label at each end of the cable shows a location designator (for example, 0A2). Both ends of the cable will have the same location designator and DA pair color code. However, the connector at each end of the same cable will usually NOT have the same color code.
  4. Location designators are in the form CTP, where:
    C
    is the device adapter pair (0-7)
    T
    is the port pair on the device adapter (A, B, C, D, a, b, c, d) (uppercase for left device adapter in pair, lowercase for right device adapter in pair).
    P
    is the logical position of the downstream FCIC in the loop.
    Example: 2a1 is the link between device adapter R1-XI4-C6-T1 and R1-G09-C1-T2.
    2
    device adapter pair 2
    a
    first port pair on right adapter of device adapter pair (lowercase a)
    1
    first FCIC on loop of this port pair
    the connector plugged into R1-XI4-C6-T1 (2a1) will be beige, while the connector plugged into R1-G09-C1-T2 (2a1) will be green.
  5. Some connectors are for cables that would go to an optional expansion rack. In that case, only one instance of that designator is on the rack.
  6. The black and white label at each end may have a physical location code in addition to the location designator.
  7. There are two FC-AL cable configurations for Rack-1:
    • Standard for Rack Configuration: AE1
    • Business class for Rack Configuration: AB1
    You determine the configuration by referring to the rack configuration label, located inside the front cover, to the left of the upper PPS power supply on the left front sidewall. Figure 1 shows the rack configuration labels.
    Figure 1. Rack-1 configuration labels
    Rack-1 configuration labels (examples)
Figure 2. Device adapter pair IDs for storage enclosures (Model 951 with business class cabling) (rear view)
Device adapter pair IDs for storage enclosures (Model 951 with business class cabling) (rear view)
Figure 3. FC-AL cable connector color codes - Fibre Channel interface card (FCIC) end
FC-AL cable connector color codes - Fibre Channel interface card (FCIC) end
Figure 4. FC-AL cable connector color codes - device adapter card (DA) end
FC-AL cable connector color codes - device adapter card (DA) end

Cabling tables

Table 1 shows a summary of business class FC-AL cabling.
Table 2 shows the unique jumpers used in business class cabling.
Table 3 and Table 4 show details of the business class FC-AL loops originating with Rack 1 device adapters (device adapter pairs 2, and 3, in normal installation order). Note that device adapter pairs 0 and 1 are not used with business class cabling.
Note: Location designators are labeled as link in the following tables.
Table 1. FC-AL cabling summary - Rack 1 device adapters (Model 951 - Rack-1 Configuration: AB1, business class cabling)

From:

DA Pair

DA

Pair (link)

To:

Storage Enclosure

To:

Storage Enclosure

To:

Storage Enclosure

R1-XI3-P1-C3-T1/T2

R1-XI4-P1-C6-T1/T2

2 (A)

2 (a)

R1-G09

R1-G01

R1-G07

R1-XI3-P1-C3-T3/T4

R1-XI4-P1-C6-T3/T4

2 (B)

2 (b)

R1-G10

R1-G02

R1-G08

R1-XI3-P1-C6-T1/T2

R1-XI4-P1-C3-T1/T2

3 (A)

3 (a)

R1-G05

R1-G03

(none)

R1-XI3-P1-C6-T3/T4

R1-XI4-P1-C3-T3/T4

3 (B)

3 (b)

R1-G06

R1-G04

(none)

Table 2. FC-AL cabling matrix - Rack 1 business class jumpers (Model 951 with Rack-1 Configuration: AB1, business class cabling)

From:

FCIC

link

To:

FCIC

DA pair 2
R1-G01-P1-C1-T3 2A5 R1-G07-P1-C1-T1
R1-G01-P1-C1-T4 2a5 R1-G07-P1-C1-T2
R1-G01-P1-C2-T3 2A6 R1-G07-P1-C2-T1
R1-G01-P1-C2-T4 2a6 R1-G07-P1-C2-T2
R1-G02-P1-C1-T3 2B5 R1-G08-P1-C1-T1
R1-G02-P1-C1-T4 2b5 R1-G08-P1-C1-T2
R1-G02-P1-C2-T3 2B6 R1-G08-P1-C2-T1
R1-G02-P1-C2-T4 2b6 R1-G08-P1-C2-T2
DA pair 3
R1-G05-P1-C1-T3 3A3 R1-G03-P1-C1-T1
R1-G05-P1-C1-T4 3a3 R1-G03-P1-C1-T2
R1-G05-P1-C2-T3 3A4 R1-G03-P1-C2-T1
R1-G05-P1-C2-T4 3a4 R1-G03-P1-C2-T2
R1-G06-P1-C1-T3 3B3 R1-G04-P1-C1-T1
R1-G06-P1-C1-T4 3b3 R1-G04-P1-C1-T2
R1-G06-P1-C2-T3 3B4 R1-G04-P1-C2-T1
R1-G06-P1-C2-T4 3b4 R1-G04-P1-C2-T2
 
Table 3. FC-AL cabling matrix - DA Pair 2 (Model 951 - Rack-1 Configuration: AB1, business class cabling)

From:

DA

link

To:

FCIC

 

From:

FCIC

link

To:

FCIC

R1-XI3-P1-C3-T1

2A1

R1-G09-P1-C1-T1

 

R1-G09-P1-C1-T3

2A3

R1-G01-P1-C1-T1

R1-XI4-P1-C6-T1

2a1

R1-G09-P1-C1-T2

 

R1-G09-P1-C1-T4

2a3

R1-G01-P1-C1-T2

R1-XI3-P1-C3-T2

2A2

R1-G09-P1-C2-T1

 

R1-G09-P1-C2-T3

2A4

R1-G01-P1-C2-T1

R1-XI4-P1-C6-T2

2a2

R1-G09-P1-C2-T2

 

R1-G09-P1-C2-T4

2a4

R1-G01-P1-C2-T2

R1-XI3-P1-C3-T3

2B1

R1-G10-P1-C1-T1

 

R1-G10-P1-C1-T3

2B3

R1-G02-P1-C1-T1

R1-XI4-P1-C6-T3

2b1

R1-G10-P1-C1-T2

 

R1-G10-P1-C1-T4

2b3

R1-G02-P1-C1-T2

R1-XI3-P1-C3-T4

2B2

R1-G10-P1-C2-T1

 

R1-G10-P1-C2-T3

2B4

R1-G02-P1-C2-T1

R1-XI4-P1-C6-T4

2b2

R1-G10-P1-C2-T2

 

R1-G10-P1-C2-T4

2b4

R1-G02-P1-C2-T2

             

From:

FCIC

link

To:

FCIC

       

R1-G01-P1-C1-T3

2A5

R1-G07-P1-C1-T1

       

R1-G01-P1-C1-T4

2a5

R1-G07-P1-C1-T2

       

R1-G01-P1-C2-T3

2A6

R1-G07-P1-C2-T1

       

R1-G01-P1-C2-T4

2a6

R1-G07-P1-C2-T2

       

R1-G02-P1-C1-T3

2B5

R1-G08-P1-C1-T1

       

R1-G02-P1-C1-T4

2b5

R1-G08-P1-C1-T2

       

R1-G02-P1-C2-T3

2B6

R1-G08-P1-C2-T1

       

R1-G02-P1-C2-T4

2b6

R1-G08-P1-C2-T2

       
Table 4. FC-AL cabling matrix - DA Pair 3 (Model 951 - Rack-1 Configuration: AB1, business class cabling)

From:

DA

link

To:

FCIC

 

From:

FCIC

link

To:

FCIC

R1-XI3-P1-C6-T1

3A1

R1-G05-P1-C1-T1

 

R1-G05-P1-C1-T3

3A3

R1-G03-P1-C1-T1

R1-XI4-P1-C3-T1

3a1

R1-G05-P1-C1-T2

 

R1-G05-P1-C1-T4

3a3

R1-G03-P1-C1-T2

R1-XI3-P1-C6-T2

3A2

R1-G05-P1-C2-T1

 

R1-G05-P1-C2-T3

3A4

R1-G03-P1-C2-T1

R1-XI4-P1-C3-T2

3a2

R1-G05-P1-C2-T2

 

R1-G05-P1-C2-T4

3a4

R1-G03-P1-C2-T2

R1-XI3-P1-C6-T3

3B1

R1-G06-P1-C1-T1

 

R1-G06-P1-C1-T3

3B3

R1-G04-P1-C1-T1

R1-XI4-P1-C3-T3

3b1

R1-G06-P1-C1-T2

 

R1-G06-P1-C1-T4

3b3

R1-G04-P1-C1-T2

R1-XI3-P1-C6-T4

3B2

R1-G06-P1-C2-T1

 

R1-G06-P1-C2-T3

3B4

R1-G04-P1-C2-T1

R1-XI4-P1-C3-T4

3b2

R1-G06-P1-C2-T2

 

R1-G06-P1-C2-T4

3b4

R1-G04-P1-C2-T2