An error communicating between two CEC enclosure system processor
cards was detected.
About this task
There is a communication error between the CEC enclosure system processor cards and the FRUs called out
before this procedure. If you were unable to correct the problem by replacing FRUs that were
previously specified before coming to this procedure, consider the possibility of failing CEC enclosure I/O backplane assembly.Note: Storage complex
repair actions must always be managed from the management console. To replace any FRUs identified in this
procedure, use . If the FRUs are listed in the serviceable events, select them from
there.
Procedure
- Use the location codes for the FRUs that were previously
specified to determine if the CEC enclosure system processor
cards are on the CEC enclosure.
Are the CEC enclosure system processor cards on
separate CEC enclosures?
- No, continue with step 2.
- Yes, perform the following steps:
- Replace the SMP cables between the two enclosures.
- Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure
- Is the problem resolved?
- Yes. This ends the procedure.
- No, continue to the next step.
- Replace the CEC enclosure system processor
backplane assembly.
- Perform a slow boot. MAP4820 Performing a slow boot of a CEC enclosure.