FSPSP55
An error has been detected on a bus between two FRUs. The endpoint FRUs have been called out. However, the source of the error could be the bus path between the FRUs.
About this task
Note: Storage complex repair actions must always be managed from the management console. To replace any FRUs identified in this
procedure, use Storage Facility Management > storage facility > Exchange Parts. If the FRUs are listed in the serviceable events, select them from there.
Procedure
- Is word 6 (the eight leftmost characters of panel function
13) of the reference code 00000001 or 00000008?
- No, go to the next step.
- Yes, perform the following steps:
- The XYZ bus or the CEC enclosure system processor card, P5IOC2 bus, has an error. Replace the FRUs called out after this procedure.
- Did replacing the FRUs correct the problem?
- Yes. This ends the procedure.
- No. Perform the following steps:
- Replace the CEC enclosure system processor backplane assembly (Un-P2) from the CEC enclosure where the FRUs were replaced.
- Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure. This ends the procedure.
- Is word 6 of reference code 00000002?
- No, go to the next step.
- Yes, perform the following steps:
- The AB bus has an error. Replace the SMP cable (Un-P2-Cx-Tx is the connector) between the FRUs called out after this procedure.
- Clear the deconfiguration errors for the FRUs called out.
- Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure.
- Did replacing the SMP cable correct the problem?
- No, replace the FRUs called out after this procedure. This ends the procedure.
- Yes. This ends the procedure.
- Is word 6 of reference code 00000004 or 00000005?
- No, go to the next step.
- Yes, perform the following steps:
- The CEC enclosure system processor card, GX card bus or PSI bus, has an error. Replace the FRUs called out after this procedure.
- Did replacing the FRUs correct the problem?
- Yes. This ends the procedure.
- No. Perform the following steps:
- Replace the CEC enclosure system processor backplane assembly (Un-P2) from the CEC enclosure where the FRUs were replaced.
- Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure. This ends the procedure.
- Does the problem persist?
- No. This ends the procedure.
- Yes. Perform the following steps:
- Replace the CEC enclosure I/O backplane assembly (Un-P1) from the CEC enclosure where the FRUs were replaced.
- Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure. This ends the procedure.
- Is word 6 of reference code 00000006?
- No, go to the next step.
- Yes. The CEC enclosure memory DIMM ( DIMM bus) has an error. Replace the FRUs called out after this procedure.
- Did replacing the FRUs correct the problem?
- No, perform the following steps:
- Replace the CEC enclosure system processor card (Un-P2-C1 or Un-P2-C2) from the CEC enclosure where the FRUs were replaced.
- Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure. This ends the procedure.
- Yes. This ends the procedure.
- No, perform the following steps:
- For any other value in word 6 of the reference code, the
bus error is corrected by the FRUs called out after this procedure.
Replace the FRUs called out after this procedure.
This ends the procedure.