Storage enclosure location codes (Models 98x, SAS flash enclosure, 24 drive slots, 2.5 inches)

The physical location identifier format is Rx-Fyy, where x is the rack number and yy is the enclosure number (01-12).

Table 1. Storage enclosure location codes (SAS flash enclosure, 24 drive slots)
Part See
Drive modules Figure 1
Enclosure services module (ESM) Figure 2
Storage enclosure midplane Figure 3
Storage enclosure power supply Figure 2
Figure 1. Storage enclosure locations (front view) (SAS flash enclosure, 24 drive slots)
Storage enclosure locations (front view) (SAS flash enclosure, 24 drive slots)
Table 2. Storage enclosure location codes (front) (SAS flash enclosure, 24 drive slots)
Location code Part name
U2nnn.D04.sssssss Storage enclosure
U2nnn.D04.sssssss-P1-Dx
(x = 1-24)
Disk drive module (DDM)
Figure 2. Storage enclosure locations (rear view) (SAS flash enclosure, 24 drive slots)
Storage enclosure locations (rear view) (SAS flash enclosure, 24 drive slots)
Table 3. Storage enclosure location codes (rear) (SAS flash enclosure, 24 drive slots)
Location code Part name
U2nnn.D04.sssssss-P1-C1 Enclosure services module (ESM)
U2nnn.D04.sssssss-P1-C1-Tx
(x = 1-3 left to right)
SAS connector on ESM
Note: Connector T3 is not used.
U2nnn.D04.sssssss-P1-C2 Enclosure services module (ESM)
U2nnn.D04.sssssss-P1-C2-Tx
(x = 1-3 left to right)
SAS connector on ESM
Note: Connector T3 is not used.
U2nnn.D04.sssssss-P1-E1 Storage enclosure power supply
U2nnn.D04.sssssss-P1-E2 Storage enclosure power supply
Figure 3. Storage enclosure midplane locations (24 DDM slot shown; 12 DDM slot similar)
Storage enclosure midplane locations
Table 4. Storage enclosure internal location codes (SAS flash enclosure, 24 drive slots)
Location code Part name
U2nnn.D04.sssssss-P1 Storage enclosure midplane

Storage enclosure physical location codes that are used in MES installation instructions

Figure 4. Rack 1-3 storage enclosure and I/O enclosure location codes (Models 984, 84E) (front view)
Note: High-performance flash enclosures are in Rack-1 and Rack-2.
Rack 1-3 storage enclosure and I/O enclosure location codes (Models 984, 84E) (front view)
Figure 5. Rack 1 storage enclosure and I/O enclosure location codes (Model 984 all-flash) (front view)
Rack 1 storage enclosure and I/O enclosure location codes (Model 984 all-flash) (front view)
Figure 6. Rack 1-5 storage enclosure and I/O enclosure location codes (single-phase Models 985, 85E) (front view)
Note: High-performance flash enclosures are in Rack-1 and Rack-2.
Rack 1-5 storage enclosure and I/O enclosure location codes (single-phase Models 985, 85E) (front view)
Figure 7. Rack 1-2 storage enclosure and I/O enclosure location codes (single-phase Models 985, 85E all-flash) (front view)
Rack 1-2 storage enclosure and I/O enclosure location codes (single-phase Models 985, 85E all-flash) (front view)
Figure 8. Rack 1-5 storage enclosure and I/O enclosure location codes (three-phase Models 986, 86E) (front view)
Note: High-performance flash enclosures are in Rack-1 and Rack-2.
Rack 1-5 storage enclosure and I/O enclosure location codes (three-phase Models 986, 86E) (front view)
Figure 9. Rack 1-2 storage enclosure and I/O enclosure location codes (three-phase Models 986, 86E all-flash) (front view)
Rack 1-2 storage enclosure and I/O enclosure location codes (three-phase Models 986, 86E all-flash) (front view)
Figure 10. Rack 1-3 storage enclosure and I/O enclosure location codes (Models 988, 88E all-flash) (front view)
Rack 1-3 storage enclosure and I/O enclosure location codes (Models 988, 88E all-flash) (front view)