Use this MAP to handle problems when a resource is not detected
by the diagnostics.
Before you begin
All storage facility repair
activity should be started from Start here.
If you have not started from that procedure, go there now and start from the
section Analyze and repair problems. If you did start
from that section and the analysis procedures produced an SRN, then follow
the steps below.
Procedure
- Are there any open serviceable events
related to the failing CEC?
- Yes, fix the related problem; then return to the procedure that sent
you to the SRN list.
- No, go to the next step.
- Was more than one SRN or error code produced by the procedure that
sent you here?
- Yes, go to the next step.
- No, contact your next level of support.
- Multiple SRNs and error codes should be handled in the following
order:
- 8-Digit Error Codes.
- SRNs with a source code other than F or G.
- SRNs with a source code of F.
- SRNs with a source code of G.
Note: The priority for multiple SRNs with a source of G is determined
by the time stamp of the failure. Follow the action for the SRN with the earliest
time stamp first.
Perform the repair action for the highest priority
SRN or error code in the order shown in the list above. Have all other SRNs
and error codes been repaired?
- Yes, contact your next level of support.
- No, perform the repair action for the next SRN or error code in the
list.