MAP31C0 SRC BE34002D Array rebuild in progress or array state
unknown
A DDM cannot be replaced in the affected array until the
array is in a known state and is not rebuilding.
MAP31C0 Section-1
Procedure
- Use the following information to repair this serviceable
event.
- The DDM to be replaced is still active in an array.
- The array is currently being rebuilt because of a prior service
action.
- Wait until the array build process is complete before repairing
this DDM.
- An array rebuild can take from 90 minutes to several hours
depending on the capacity of the DDMs and the level of system activity.
- Retry the DDM replacement later.
- To check the array state,
have the customer check the rank datastate using the IBM® System Storage DS® Command-Line Interface (CLI).
- Using the dscli, issue the lsrank command.
For example, dscli> lsrank.
- Look at the 'datastate' column. For help, issue "help
lsrank" to see information on the lsrank command, including the list
of possible datastates and their meaning.
- The rebuild process is complete when the datastate indicates
'Normal'