MAP4A40 Code update CCL process was automatically suspended

This MAP is called for a CCL Activate Step that is automatically suspended by CCL. A code update process activate step running under CCL has been automatically suspended by an unexpected problem that should have created a separate serviceable event from the one that sent you here.

About this task

This MAP is called for a CDA Activate Step that is automatically suspended by CDA.

MAP4A40 Section-1

Procedure

  1. In addition to the serviceable event that sent you here, are there any other open serviceable events?
    • Yes, continue with step 3.
    • No, continue with step 2.
  2. Did you already repair a related serviceable event or problem?
    • Yes, go to step 4.
    • No, the code update has failed with no associated error, contact your next level of support.
  3. Display the serviceable event details for the other serviceable event that did not send you here. Use Table 1 to prioritize the repair sequence.
    Note: You will not be able to reselect the serviceable event in the original window that you used to select it when you began this repair. Instead, return to the main HMC menu selection and repeat the steps to view serviceable events.
    Table 1. MAP4A40 repair prioritization
    Serviceable event type Repair Sequence Action
    CEC enclosure serviceable event 1 Repair the serviceable event and then return here and continue.
    All other problems except any serviceable event with MAP4A50 in the FRU list 2 Repair the serviceable event and then return here and continue.
    Serviceable event with MAP4A50 in FRU list 3 Repair the serviceable event and then return here and continue.
    All other serviceable events repaired 4 Go to the next step.
  4. Exit this MAP and go to MAP4A60.