MAP4A70 Concurrent code load update process completed but not all resources were updated
A concurrent code load (CCL) update process detected a problem during the update and was able to continue. Not all code updates were completed.
MAP4A70 Section-1
Procedure
MAP4A70 Section-2
Procedure
The code update of the host card failed while
accessing the port listed in the FRU group. The replace FRU process
for the host adapter card automatically attempts to load the latest
code available on the host card ports. The host card and the host
card ports might not be bad, but instead might only need the code
update attempted again. Go to MAP4A70 Section-3.
MAP4A70 Section-3
About this task
The code update of the host cards listed in the FRU group failed. The replace FRU process automatically attempts to load the latest code available on the host card. The host card might not be bad, but instead might only need the code update attempted again.
The host card needs to be quiesced and then resumed to complete the code load process. There are no utilities to do this. Instead, you will do a pseudo parts exchange of the host card. A pseudo parts exchange means you use the serviceable event FRU replace process, but do not disconnect the host cables or remove the host card when prompted.