MAP6570 Diskette drive problem
Use this procedure to test the diskette drive in the PC for the management console.
MAP6570 Section-1
Procedure
- Turn on the PC power and test the diskette drive using
the information in MAP6530 Testing the management console. Select Extended, then Diskette
Drive. Note: Do not test with the diskette on which the errors occurred. Use a new diskette.
When the test is complete, continue with the next step.
- Did the diskette test fail while testing with a new diskette?
Note: Answer Yes if you were not able to run the test because of the diskette errors.
- Yes, continue with the next step.
- No, go to step 5.
- Exchange the diskette drive. When complete, run the diskette
test again.
Did the diskette test fail again?
- Yes, continue with the next step.
- No, the original diskette drive was failing. This ends the procedure.
- Continue exchanging FRUs from the FRU list and running tests. If the FRUs fix the problem, this ends the procedure. If you cannot resolve the problem, contact your next level of support.
- Did the original failure occur while writing
to a diskette?
- Yes, continue with the next step.
- No, go to step 7.
- Retry the original task using a new diskette.
- If the failure occurs again, go to step 8.
- If no failure occurs, the original diskette was failing. This ends the procedure.
- Recreate the information on the diskette
or get a new diskette with the information. Retry the original task.
- If the failure occurs again, continue with the next step.
- If no failures occur, the original diskette was failing. This ends the procedure.
- Test the diskette drive, using the information
in MAP6530 Testing the management console. Select System Unit problem
area and the test of Diskette Drive.
- If the test fails, isolate the problem using the procedures found in the appropriate management console hardware maintenance manual.
- If the test does not – or if you cannot – isolate the problem, contact your next level of support.