The server (managed system) detected an error in the power system.
PWR1918 Section-1
About this task
Note: Storage complex repair actions must always be managed from the
management console. To replace any FRUs identified in this procedure, use . If the FRUs are listed in
this or another Serviceable Event, select them from there.
For storage facility Model 961, use Table 1 to determine the failing FRU.
For storage facility
Models 941 and 951, use Table 2 to determine
the failing FRU.
| Reference code | Description/Action |
|---|---|
| 1xxx 2611 | Replace the following, if present, one at a
time, and in the order listed:
|
| 1xxx 2622 | Replace the following, if present, one at a
time, and in the order listed:
|
| 1xxx 2623 | Replace the following, if present, one at a
time, and in the order listed:
|
| 1xxx 2625 | Replace the following, if present, one at a
time, and in the order listed:
|
| 1xxx 2626 | Replace the following, if present, one at a
time, and in the order listed:
|
| 1xxx 2691 | Perform the following steps:
|
| 1xxx 8450 | At least one VRM is missing from the system unit. Inspect all of the processor cards and memory cards and install the VRMs that are missing. See CEC enclosure location codes (Model 961) for FRU location information for the system that you are servicing. |
| 1xxx 8453 | There is an extra processor regulator in the system. Remove the extra regulator. |
| 1xxx 8454 | A fan at location Un-A3 is installed in a single-socket system. This configuration is not valid. Remove the fan at location Un-A3. |
| 1xxx 8457 | Low-power processor VRMs were installed on the
system. The system requires high-power processor VRMs. Replace the
processor VRMs with the correct part number. If you received this error after replacing a VRM, check that VRM first. If you received this error after replacing a processor module, check that the correct processor module FRU was used. |
| 1xxx 8458 | Low-power processor VRMs were installed on the
system. The system requires high-power processor VRMs. Replace the
processor VRMs with the correct part number. If you received this error after replacing a VRM, check that VRM first. If you received this error after replacing a processor module, check that the correct processor module FRU was used. |
| Reference code | Description/Action |
|---|---|
| 1xxx 1611, 1612, or 1613 | Processor voltage regulator 1 at location Un-P2-C3 is failing. Replace it. |
| 1xxx 1621, 1622, or 1623 | Processor voltage regulator 2 at location Un-P2-C4 is failing. Replace it. |
| 1xxx 1631, 1632, or 1633 | Processor voltage regulator 3 at location Un-P2-C5 is failing. Replace it. |
| 1xxx 2602 and all other reference codes | Failing processor voltage regulator card cannot be determined. Replace processor voltage regulator cards sequentially. If 1xxx 2602 appears again, replace CEC enclosure system processor backplane assembly Un-P2. |
| 1xxx 8450 | Fewer processor voltage regulator cards than processor cards are installed. |
| 1xxx 8451 | Too few processor voltage regulator cards installed. |