PROCPHB
The failing item might be the PCI Host Bridge (PHB) on a system processor.
Perform the following steps to determine the location of the system processor module:
- Is a location code available in the serviceable event view for this failing item?
- Yes: Use the location to find and replace the failing system processor. This ends the procedure.
- No: Continue with the next step.
- To determine the location of the failing item, perform the following steps:
- Record the dynamic reconfiguration connector (DRC) index, which is word 7 of the reference code.
- If the DRC is of the form 2000yyyy or 210xyyyy, continue with the next step. If the DRC is of the form 2300yyyy, 2400yyyy, or 2B00yyyy go step 4.
- The DRC index from the previous step is of the form xxxxyyyy, where
yyyy is the hexadecimal bus number. Using the
hexadecimal bus number, refer to Table 3, Table 4, or Table 5 to find the location code that is associated with the bus
number. Use the location code and the following table to determine the
location code of the failing system processor module to replace.
Table 1. Locating the failing item by using the bus location code Type and model Bus location code Description Failing item location Model 980, 983, or 984 (8284-22A); Model 981, 985, or 986 (8286-42A) Un-P1, Un-P1-C6 through Un-P1-C15 System processor module Un-P1-C32 Model 980, 983, or 984 (8284-22A); Model 981, 985, or 986 (8286-42A) Un-P1-C2 through Un-P1-C5 System processor module Un-P1-C33 Model 982 or 988 (8408-44E or 8408-E8E) Un-P1-C1, Un-P1-C2 System processor module Un-P2-C7 Model 982 or 988 (8408-44E or 8408-E8E) Un-P1-C3, Un-P1-C4 System processor module Un-P2-C6 Model 982 or 988 (8408-44E or 8408-E8E) Un-P1, Un-P1-C6 through Un-P1-C9 System processor module Un-P2-C3 Model 982 or 988 (8408-44E or 8408-E8E) Un-P1-C10 through Un-P1-C12 System processor module Un-P2-C2 Model 982 or 988 (8408-44E or 8408-E8E) Un-P3 System processor module Un-P2-C2 and Un-P2-C3 - Use the DRC index from step 2 and the following
table to find the location code of the failing system processor module to replace.
Table 2. Locating the failing item by using the DRC index Type and model DRC index Description Location Model 980, 983, or 984 (8284-22A); Model 981, 985, or 986 (8286-42A) - 23000000
- 23000001
- 24000000
- 24001000
System processor module Un-P1-C32 Model 980, 983, or 984 (8284-22A); Model 981, 985, or 986 (8286-42A) - 23000002
- 23000003
- 24002000
- 24003000
System processor module Un-P1-C33 Model 982 or 988 (8408-44E or 8408-E8E) - 23000000
- 23000001
System processor module Un-P2-C2 Model 982 or 988 (8408-44E or 8408-E8E) - 23000002
- 23000003
System processor module Un-P2-C3 Model 982 or 988 (8408-44E or 8408-E8E) - 23000004
- 23000005
System processor module Un-P2-C6 Model 982 or 988 (8408-44E or 8408-E8E) - 23000006
- 23000007
System processor module Un-P2-C7
The following information correlates PCI bus numbers to PCI card location codes for the listed machine types and models.
PCI bus numbers in system units are assigned as indicated in the following tables. PCI bus numbers in expansion units are assigned by Licensed Internal Code or firmware as the buses are discovered.
| Bus number (hexadecimal/decimal) | Item that is designated by the bus number | Location |
|---|---|---|
| 1B/27 | PCIe embedded USB controller
|
Un-P1 |
| 28/40 | PCIe3 x8 IOA card | Un-P1-C2 |
| 29/41 | PCIe3 x16 IOA card | Un-P1-C3 |
| 21/33 | PCIe3 x16 IOA card | Un-P1-C5 |
| 18/24 | PCIe3 x16 IOA card | Un-P1-C6 |
| 10/16 | PCIe3 x16 IOA card | Un-P1-C7 |
| 1D/29 | PCIe3 x8 IOA card | Un-P1-C9 |
| 1E/30 | PCIe3 x8 IOA card | Un-P1-C10 |
| 13/19 | PCIe3 x8 IOA card | Un-P1-C11 |
| 14/20 | PCIe3 x8 IOA card | Un-P1-C12 |
| 15/21 | PCIe3 x8 SAS RAID internal adapter or PCIe3 x8 cache SAS RAID internal adapter | Un-P1-C14 |
| 1F/31 | PCIe3 x8 SAS RAID internal adapter or PCIe3 x8 cache SAS RAID internal adapter | Un-P1-C15 |
| Bus number (hexadecimal/decimal) | Item that is designated by the bus number | Location |
|---|---|---|
| 1B/27 | PCIe embedded USB controller
|
Un-P1 |
| 28/40 | PCIe3 x8 IOA card | Un-P1-C2 |
| 29/41 | PCIe3 x16 IOA card | Un-P1-C3 |
| 20/32 | PCIe3 x8 IOA card | Un-P1-C4 |
| 21/33 | PCIe3 x16 IOA card | Un-P1-C5 |
| 18/24 | PCIe3 x16 IOA card | Un-P1-C6 |
| 10/16 | PCIe3 x16 IOA card | Un-P1-C7 |
| 1C/28 | PCIe3 x8 IOA card | Un-P1-C8 |
| 1D/29 | PCIe3 x8 IOA card | Un-P1-C9 |
| 1E/30 | PCIe3 x8 IOA card | Un-P1-C10 |
| 13/19 | PCIe3 x8 IOA card | Un-P1-C11 |
| 14/20 | PCIe3 x8 IOA card | Un-P1-C12 |
| 15/21 | PCIe3 x8 SAS RAID internal adapter or PCIe3 x8 cache SAS RAID internal adapter | Un-P1-C14 |
| 1F/31 | PCIe3 x8 SAS RAID internal adapter or PCIe3 x8 cache SAS RAID internal adapter | Un-P1-C15 |
| Bus number (hexadecimal/decimal) | Item that is designated by the bus number | Location |
|---|---|---|
| 2B/43 | PCIe embedded USB controller on I/O backplane
|
Un-P1 |
| 40/64 | PCIe3 x16 IOA card | Un-P1-C1 |
| 48/72 | PCIe3 x16 IOA card | Un-P1-C2 |
| 30/48 | PCIe3 x16 IOA card | Un-P1-C3 |
| 38/56 | PCIe3 x16 IOA card | Un-P1-C4 |
| 2C/44 | PCIe3 x8 IOA card | Un-P1-C6 |
| 2D/45 | PCIe3 x8 IOA card | Un-P1-C7 |
| 20/32 | PCIe3 x16 IOA card | Un-P1-C8 |
| 28/40 | PCIe3 x16 IOA card | Un-P1-C9 |
| 10/16 | PCIe3 x16 IOA card | Un-P1-C10 |
| 18/24 | PCIe3 x8 IOA card | Un-P1-C11 |
| 19/25 | PCIe3 x16 IOA card | Un-P1-C12 |
| 11/17 | PCIe3 embedded storage controller (Un-P3-R2) on RAID card (Un-P3) | Un-P3 |
| 21/33 | PCIe3 embedded storage controller (Un-P3-R1) on RAID card (Un-P3) | Un-P3 |
This ends the procedure.