Exchange the CEC enclosure control panel

Before you begin

Icon for electrostatic discharge wrist strapUse approved ESD procedures to prevent damage.

Attention:
  • This procedure is not a stand-alone procedure. Customer disruption and damage to the hardware might occur when microcode and power boundaries are not in the proper conditions for this service action.
  • If a serviceable event FRU repair directed you to this procedure, the microcode and power boundaries are already set.
  • If a serviceable event FRU repair did not direct you to this procedure, see MAP1230 Replace a FRU without using a serviceable event.
Notes:
  • All the cables and FRUs to be removed must be uniquely identified so they can be reinstalled correctly.
  • If an installed earthquake resistance kit prevents you from accessing this FRU, refer to MAP1600.

Remove the CEC enclosure control panel

Procedure

  1. Verify that the CEC enclosure is in the "power off" state before you continue. (The CEC enclosure should already be in the power off state.)
    Note: If this FRU has a FRU identify indicator LED, it is no longer lit.

    If you have not already located the FRU to be replaced, use the location code listed in the serviceable event FRU list. See MAP1245 Finding FRUs by using location codes.

  2. At the rear of the storage facility, view both CEC enclosure power supplies.
    Figure 1. CEC enclosure DC good LEDs
    CEC enclosure DC good LEDs

    Are both DC GOOD LEDs flashing?

  3. Remove all power from the CEC enclosure.
    • At the rear of the CEC enclosure, disconnect the power input cables Callout label A to both CEC enclosure power supplies.
    • At the CEC enclosure control panel, observe the green Power® Present icon, beneath the white Power button.
      • If it is slow flashing, the CEC enclosure is still in the power-off state. DO NOT CONTINUE. Ensure that you have unplugged the power cables.
      • If it is off, go to the next step.
    Figure 2. CEC enclosure (rear)
    CEC enclosure (rear)
  4. At the front of the CEC enclosure, remove the control panel by pressing the locking tabs Callout label A located on either side of the panel, grasping the edges of the panel, and pulling it out of its bay Callout label A.
    See Figure 3.
    Figure 3. Removing the CEC enclosure control panel
    Removing the CEC enclosure control panel

Install the CEC enclosure control panel

Procedure

  1. Transfer the machine type model serial number (MTMS) label from the old control panel to the new control panel.
    Note: Pry the center of the MTMS label away from the control panel bezel so the tabs on each end are released.
  2. At the front of the CEC enclosure, carefully slide the control panel into the control panel bay until you feel the locking tabs lock in place.
  3. At the rear of the CEC enclosure, connect the power input cables to both CEC enclosure power supplies.
  4. Ensure that the CEC enclosure is in the power-off state before you continue. At the CEC enclosure control panel, wait for the green Power Present icon, beneath the white Power button to slow blink, and then continue the repair.
  5. Exit this service information center parts exchange procedure and return to the procedure that sent you here.