The system has detected that a processor chip is missing
from the system configuration because JTAG lines are not working.
Before you begin
Note: Storage complex repair actions must always be managed from the
management console. To replace any FRUs identified in this procedure, use . If the FRUs are listed in
this or another Serviceable Event, select them from there.
Procedure
- Replace the CEC enclosure service processor card using
symbolic FRU SVCPROC.
- Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure.
- Does the problem persist?
- Yes, continue with the next step.
- No, this ends the procedure.
- Perform the following for each system processor until the
problem is resolved:
- Replace one CEC enclosure system processor
card at a time using using symbolic FRU ANYPROC.
- Perform a slow boot after replacing each processor.
What to do next
This ends the procedure.