FSPSP27

An attention line has been detected as having a problem.

Before you begin

If the FRU replaced before this procedure did not correct the problem, perform the following steps.

Procedure

  1. Was the FRU called out before this procedure a memory DIMM (Un-P2-C1-Cx or Un-P2-C2-Cx)?
    • No: go to step 10.
    • Yes: A memory DIMM attention line has an error. Continue to the next step.
  2. Replace the CEC enclosure service processor card (Un-P1-C11) from the same CEC enclosure as the memory DIMM.
  3. Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure.
  4. Does the problem persist?
    • No: This ends the procedure.
    • Yes: Continue to the next step.
  5. Replace the CEC enclosure system processor card (P2-C1 or P2-C2) on which you previously replaced memory DIMMs.
  6. Perform a slow boot.
  7. Does the problem persist?
    • No: This ends the procedure.
    • Yes: Continue to the next step.
  8. Replace the CEC enclosure I/O backplane assembly (P1) from the same CEC enclosure as the memory DIMM.
  9. Perform a slow boot.
  10. Was the FRU called out before this procedure a CEC enclosure system processor card (P2-C1 or P2-C2) or GX adapter card (P1-C8 or P1-C9)?
    • No: Go to step 16.
    • Yes: A CEC enclosure system processor card or GX adapter card attention line has an error. Continue to the next step.
  11. Replace the CEC enclosure service processor card (P1-C11) from the CEC enclosure as the CEC enclosure system processor card or GX adapter card.
  12. Perform a slow boot.
  13. Does the problem persist?
    • No: This ends the procedure.
    • Yes: Continue to the next step.
  14. Replace the CEC enclosure I/O backplane assembly (Un-P1) from the same CEC enclosure drawer as the CEC enclosure system processor card or GX adapter card.
  15. Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure. This ends the procedure.
  16. Was the FRU called out before this the CEC enclosure I/O backplane assembly (Un-P1)?
    • No: Contact your next level of support. This ends the procedure.
    • Yes: A P5IOC2 attention line has an error. Continue to the next step.
  17. Replace the CEC enclosure service processor card (P1-C11) from the CEC enclosure as the CEC enclosure I/O backplane assembly.
  18. Perform a slow boot. This ends the procedure.