The system detected an error within the JTAG path.
Before you begin
Note: Storage complex repair actions must always be managed from the
management console. To replace any FRUs identified in this procedure, use Storage Facility Management > storage facility > Exchange Parts. If the FRUs are listed in
this or another Serviceable Event, select them from there.
Procedure
- Has a CEC enclosure
memory DIMM (Un-P2-C1-Cx or Un-P2-C2-Cx) been replaced?
- No, go to step 10.
- Yes, a CEC enclosure memory DIMM attention line has an error. Continue to the next step.
- Replace the CEC enclosure service processor card (Un-P1-C11) in the same CEC enclosure.
- Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure.
- Does the problem
persist?
- No: This ends the procedure.
- Yes: Continue to the next step.
- Replace the CEC enclosure system processor card (Un-P2-C1 or Un-P2-C2) on which a CEC enclosure memory DIMM has been replaced.
- Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure.
- Does the problem
persist?
- No: This ends the procedure.
- Yes: Continue to the next step.
- Replace the CEC enclosure I/O backplane assembly (Un-P1) in the same CEC enclosure as the CEC enclosure memory DIMM.
- Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure. This ends the procedure.
- Has a CEC enclosure
system processor card (Un-P2-C1 or Un-P2-C2) or GX adapter card (Un-P1-C8
or Un-P1-C9) been replaced?
- No: Go to step 16.
- Yes: A CEC enclosure system processor card or GX adapter card attention line has an error. Continue to the next step.
- Replace the CEC enclosure service processor (Un-P1-C11) from the CEC enclosure as the CEC enclosure system processor card or GX adapter card.
- Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure.
- Does the problem persist?
- No: This ends the procedure.
- Yes: Continue to the next step.
- Replace the CEC enclosure I/O backplane assembly (Un-P1) from the CEC enclosure as the CEC enclosure processor card or GX adapter card.
- Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure. This ends the procedure.
- Was the CEC enclosure
I/O backplane assembly (Un-P1) explicitly called out as a FRU before
starting step 1 of this procedure?
- No: Contact your next level of support. This ends the procedure.
- Yes: A P5IOC2 attention line has an error. Continue to the next step.
- Replace the CEC enclosure service processor card (Un-P1-C11) from the same CEC enclosure as the CEC enclosure system backplane.
- Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure.