FWVTHMC

The partition firmware is waiting for a virtual terminal to be opened on the management console.

Procedure

  1. Open a virtual terminal.
  2. If a virtual terminal is open, the user might have entered a CTRL-S key sequence to stop the scrolling of data off the screen. If this is the case, enter a CTRL-Q key sequence to resume scrolling.
  3. Check the Ethernet connection between the management console and the managed system.
  4. Reboot the management console.
  5. There might be a hardware problem with the management console. Go to MAP6020 Management console problem determination.
  6. There might be a hardware problem with the service processor in the managed system. Check the Service Management > Manage Serviceable Events view for error codes that indicate a problem with the Ethernet ports on the service processor. Take the appropriate actions based on the error codes that you find.

What to do next

This ends the procedure.