LICCODE
There is a platform LIC failure.
Procedure
- Are any other FRUs or procedures listed before LICCODE for this serviceable event or reference
code?
- Yes, try to resolve the problem by replacing those FRUs or performing those procedures first.
- No, go to step 2.
- Read the following before taking any action:
- The root cause of the error that sent you here is most likely due to a hardware error. It is less likely that the problem is due to a code or firmware error.
- There might be multiple serviceable events for a single error, each for a different aspect of the error. Review all open serviceable events before proceeding.
- Look for open serviceable events with FRUs that might be related to this problem. It is possible for related FRUs to be outside of the CEC enclosure. For example, the RPC card has a communication interface to the service processor card.
- The time stamp of the related serviceable event can be before or after the time stamp of the serviceable event that sent you here. For example, an RPC card error might take several minutes to be reported by the managing LPAR, whereas a service processor error might report in less time.
- The serviceable event with the earliest time stamp might not be the root cause of the error.
- Check Retain for any Tips for the SRC in the serviceable event that sent you here.
- Contact your next level of support for guidance as needed.