SLOTERR

The multi-adapter bridge detected a problem with a card location that it controls.

Before you begin

Note: Storage complex repair actions must always be managed from the management console. To replace any FRUs identified in this procedure, use Storage Facility Management > storage facility > Exchange Parts. If the FRUs are listed in this or another Serviceable Event, select them from there.

About this task

The problem is in the controls for the card slot. The card location may or may not have an installed card. If there is a card installed in that location, it may be the source of the problem. In some cases, the user interface view of the serviceable event will list more than one card position for the location of this FRU. The problem may be with any one of the FRUs in those locations. When there is a list of locations in the location code for this FRU, the card locations will be separated by commas. A range of card positions will show the starting card position, a colon, and the ending card position.

Procedure

  1. Replace in turn each PCI card listed in the Serviceable Event.
  2. If the problem persists replace the I/O enclosure backplane that the PCI cards are plugged into.

What to do next

This ends the procedure.