This is an unexpected error for this machine type.
Before you begin
You should first resolve any other serviceable events on this machine
and if this problem persists you should then call your next level of support. This
ends the procedure.
About this task
The following is the information from the eServerâ„¢ product on which this machine
is based. This information might be of use to your support engineer.
Note: This
is background information for support use only. It is not necessarily applicable
to this machine.
The card in the given slot is not available for
use.
Procedure
- Is the unit reference code 2250 or 2300?
- Yes, the first two characters in word 4 of the reference code will
identify the platform LIC component that has control of the slot. Continue
with the next step.
- No, continue with step 3.
- What is the value of the first two characters of word 4 of the
reference code?
- 81: The component that has control of the slot is concurrent maintenance.
The concurrent maintenance procedure must complete before the partition will
IPL.
- 02 or 03: The component that has control of the slot is the management console service
or management console configuration.
Make sure that the management console functions
are not using the slot.
- Other: Contact your next level of support.
This ends the procedure.
- Is the unit reference code 2475?
- Yes, continue with the next step.
- No, contact your next level of support. This ends the procedure.
- Look in the serviceable event view for part numbers and location
codes associated with the card slot.
Note: There is no part number
if the card slot is empty.
If the reference code is on the control panel,
look in the FRU call out section of the reference code for the location of
the card slot. Use the location information to see if a card is physically
present in the card slot.
Is a card physically present?
- Yes, exchange the failing card.
- No, use symbolic FRU LPARCFG to
reconfigure the card slot so that it is not a required resource to IPL the
partition.