BE5xxxxx
This section lists the BE5xxxxx system reference codes.
These SRCs normally occur while the customer is using the DSCLI to logically configure the storage.
The SRCs listed in the tables can be caused by hardware problems. Look for open related serviceable events to repair.
There are BE5xxxxx and BE7xxxxx codes that are not actual SRCs. They are internal codes used to present status to the ESSNI GUI logical configuration options. They are not expected to display in a serviceable event. The DS8000 Messages Reference document lists cross references from the eight-character code to the message code and text. The SRCs may also be listed in the PE database or Web site document BE5xxxxx & BE7xxxxx Logical Configuration Error Codes. If the BE5xxxxx and BE7xxxxx codes are not listed in either location, contact your next level of support.
| System Reference Code | Description |
|---|---|
| BE504900 | Failing track log available for next level of support |
| BE504901 | Data loss events reported on a system configured in a copy services relationship as a secondary. Data will be recovered on next establish pair operation. |
| BE504902 | Data loss events reported on a system configured in a copy services relationship as a secondary. Data will not be recovered on next establish pair operation. |
| BE504903 | Data loss events reported on a system configured in a copy services relationship as a secondary. Data will not be recovered on next establish pair operation. |
| BE504905 | Invalid data found in NVS |
| BE504910 | Data check one sector medium error |
| BE504911 | Data check (medium error) occurred on one sector on a system configured in a copy services relationship as a secondary |
| BE504920 | Data check multiple sectors medium error |
| BE504921 | Data check (medium error) occurred on multiple sectors on a system configured in a copy services relationship as a secondary |
| BE504930 | Data check one sector LRC |
| BE504940 | Data check multiple sectors LRC |
| BE504960 | Second occurrence of customer data sequence number error |
| BE504970 | Second occurrence of customer data physical address |
| BE504980 | Metadata check one sector medium error |
| BE504990 | Metadata check multiple sectors medium error |
| BE5049A0 | Metadata check one sector LRC |
| BE5049B0 | Metadata check multiple sectors LRC |
| BE5049E0 | Data loss handling complete |
| BE5049F1 | Error information record LRC error, possible data check |
| BE5049F2 | Data check error identified in Cache with a zHyperLink write. |
| BE5049F3 | Data check error identified in NVS with a zHyperLink write. |
| BE508FF0 | IBM.essStorageAgentRM inoperational |
| BE508FF1 | IBM.essHostAgentRM inoperational |