BE8xxxxx

This section lists the BE8xxxxx system reference codes.

If the SRC listed in a serviceable event is missing from the following table, ask your next level of support for assistance.
Note: Next level, inform development of any SRCs not defined in the table.
Table 1. BE80xxxx System Reference Codes
System Reference Code Description
BE80CB00 Recovery error, soft device bus error recovered by the IOA.
BE80CB01 Recovery error, device bus fabric error.
BE80CB04 Recovery error, the IOA recovered the logical block LRC error on the host to IOA transfer.
BE80CB05 Recovery error, the IOA recovered the count key data transfer LRC error on the host to IOA transfer.
BE80CB06 Recovery error, the IOA recovered the logical block sequence number error on the host to IOA transfer.
BE80CB07 Recovery error, the IOA recovered the IOADL tag/sequence number error.
BE80CB08 Recovery error, the IOA recovered the logical block CRC error on the IOA to host transfer.
BE80CB09 Recovery error, the IOA recovered the logical block sequence number error on the IOA to host transfer.
BE80CB0A Recovery error, the IOA recovered from a logical block reference tag error.
BE80CB0B Recovery error, the IOA recovered from a logical block guard error.
BE80CB0E Recovery error, IOA sector reassignment successful.
BE80CB11 Recovery error, the IOA recovered the soft PCI bus error.
BE80CB12 Recovery error, the IOA recovered the device hardware error.
BE80CB13 Recovery error, the device recovered the device hardware error.
BE80CB14 Recovery error, the IOA recovered the soft IOA error.
BE80CB15 Recovery error, the IOA recovered the undefined device response.
BE80CB17 Recovery error, failure prediction threshold exceeded.
BE80CB1A IOA not ready, IOA requested reset.
BE80CB1C Media error, data unreadable, recommend reassignment.
BE80CB1F Hardware error, IOA cannot communicate with device.
BE80CB20 Hardware error, device bus error or device error.
BE80CB21 Hardware error, the device or IOA command has timed out.
BE80CB22 Hardware error, device bus fabric error.
BE80CB29 Hardware error, logical block CRC error on IOA to host transfer.
BE80CB2B Hardware error, logical block reference tag error detected by the IOA.
BE80CB2C Hardware error, logical block guard error detected by the IOA.
BE80CB2D Hardware error, IOA reserved area data check.
BE80CB2E Hardware error, the IOA reserved area has an invalid data pattern.
BE80CB2F Hardware error, the IOA reserved area has T10 DIF error.
BE80CB30 Hardware error, reassignment space exceeded.
BE80CB31 Hardware error, data transfer is out of minimum length.
BE80CB32 Hardware error, data transfer is out of maximum length.
BE80CB34 Hardware error, device error.
BE80CB35 Hardware error, IOA Error.
BE80CB36 Hardware error, undefined device response.
BE80CB37 Hardware error, IOA microcode error.
BE80CB38 Hardware error, the IOA must be reset to recover from an error.
BE80CB3A Hardware error, previously missing or failed device detected but has been significantly altered.
BE80CB3B Hardware error, encountered a data check on a read or write performed to a sector just after that sector was reassigned.
BE80CB3C Hardware error, encountered a T10 DIF error on read to a sector just after that sector was written.
BE80CB3D Hardware error, SAS command or task management function failed.
BE80CB3E Hardware error, different (incompatible) device detected at resource address of previously failed device. The new device cannot be utilized.
BE80CB3F Hardware error, invalid multi-adapter configuration.
BE80CB40 Hardware configuration error, incorrect connection between cascaded enclosures.
BE80CB41 Hardware configuration error, connections exceed IOA design limits.
BE80CB42 Hardware configuration error, incorrect multipath connection.
BE80CB43 Hardware error, unsupported enclosure function.
BE80CB44 Device adapter failed to read cable VPD.
BE80CB45 Hardware error, command to logical unit failed.
BE80CB48 Hardware error, device error, security threshold exceeded.
BE80CB49 Hardware error, IOA error, the encryption password is not correct.
BE80CB4A Unit Attention, rebuild of replaced/repaired device automatically restarted.
BE80CB4D Unit Attention, device bus was reset, expander may be at fault.
BE80CB50 Unit Attention, performance degradation, device bus running at slower than expected speed.
BE80CB55 Unit Attention, asymmetric advanced function DASD configuration.
BE80CB56 Unit Attention, configuration error, incomplete multipath connection between IOA and enclosure.
BE80CB57 Unit Attention, configuration error, incomplete multipath connection between enclosures and device.
BE80CB58 Unit Attention, configuration error, incomplete multipath connection between IOA and remote IOA.
BE80CB5A Unit Attention, enclosure does not support a required multipath function (OEM unit).
BE80CB5D Unit attention, configuration error, invalid cable vital product data detected.
BE80CB5F Unit Attention, data loss on logical unit.
BE80CB62 Unit attention, corrupt array parity detected, parity was not resynchronized.
BE80CB63 Unit Attention, array exposed, rebuilding will start soon if there is an available spare.
BE80CB66 Unit attention, array exposed but still protected.
BE80CB69 Unit Attention, Multipath redundancy level is incorrect.
BE80CB70 Data Protect, two or more devices are missing in this array, and only one device is present.
BE80CB71 Data Protect, two or more devices are missing in this array, and two or more devices are present.
BE80CB72 Data Protect, exposed array is short a required device.
BE80CB73 Data Protect, one or more disk array members are not at required physical locations.
BE80CB74 Data Protect, physical location of the disk array members conflict with another disk array.
BE80CB75 Data Protect, previously degraded disk in the disk array not found at required physical location.
BE80CB76 Data Protect, array is missing a device and parity is out of synchronization.
BE80CB77 Data Protect, maximum number of arrays already exist.
BE80CB7A Data Protect, IOA is out of free device identifiers.
BE80CB7C Data Protect, creation of an exposed mode device for an array would cause IOA to exceed the maximum number of devices.
BE80CB7D Data Protect, missing an array out of a volume set, the volume set is not functional.
BE80CB80 Data Protect, maximum number of volume sets already exist.
BE80CB82 SIS adapter unit check data error.
BE80CB83 SIS adapter reset timeout.
BE80CBBD Unit Attention reported due to a storage enclosure RAID controller operating at a high temperature for a prolonged duration.
Table 2. BE82xxxx System Reference Codes
System Reference Code Description
BE820100 I2C bus 0 hung.
BE820101 I2C bus 1 hung.
BE820102 I2C bus 2 hung.
BE820103 I2C bus 3 hung.
BE820104 I2C bus 4 hung.
BE820105 I2C bus 5 hung.
BE820106 I2C bus 6 hung.
BE820107 I2C bus 7 hung.
BE82010F Fan controller 1 I2C bus received NACK.
BE820110 Fan controller 2 I2C bus received NACK.
BE820114 Local expander monitoring component (420) has reported an error.
BE820115 Opposite Expander I2C bus received NACK.
BE820116 Alternate expander monitoring component (420) has reported an error.
BE82011B Fan 0 is not present or has low RPM.
BE82011C Fan 1 is not present or has low RPM.
BE82011D Fan 2 is not present or has low RPM.
BE82011E Fan 3 is not present or has low RPM.
BE820122 RAID processor on RAID controller C1 temperature sensor read failure.
BE820126 PPC on RAID controller C1 temperature sensor read failure.
BE82012A Expander on RAID controller C1 temperature sensor read failure.
BE82012E Ambient 1 on RAID controller C1 temperature sensor read failure.
BE820132 Ambient 2 on RAID controller C1 temperature sensor read failure.
BE820136 Power supply 1 on RAID controller C1 temperature sensor read failure.
BE82013A Power supply 2 on RAID controller C1 temperature sensor read failure.
BE82013E RAID processor on RAID controller C2 temperature sensor read failure.
BE820142 PPC on RAID controller C2 temperature sensor read failure.
BE820146 Expander on RAID controller C2 temperature sensor read failure.
BE82014A Ambient 1 on RAID controller C2 temperature sensor read failure.
BE82014E Ambient 2 on RAID controller C2 temperature sensor read failure.
BE820152 Power supply 1 on RAID controller C2 temperature sensor read failure.
BE820156 Power supply 2 on RAID controller C2 temperature sensor read failure.
BE820160 Loss of power on both power supplies.
BE820161 Power Supply 1 VPD data error, checksum or corruption.
BE820162 Power Supply 1 no response on I2C interface.
BE820163 Power supply unit (PSU) 1 missing.
BE820165 Power Supply 1 fan fault.
BE820166 Power Supply 1 thermal fault.
BE820167 Power supply unit (PSU) 1, DC over voltage.
BE820168 Power supply unit (PSU) 1, DC under voltage.
BE820169 Power supply unit (PSU) 1, DC over current.
BE820170 Power supply unit (PSU) 2 missing.
BE82016A VCO unit 1, DC under voltage.
BE82016B Power Supply 1 current share warning.
BE82016C Power supply unit (PSU) 1, DC fail.
BE82016E Power Supply 2 VPD data error, checksum or corruption.
BE82016F Power Supply 2 no response on I2C interface.
BE820172 Power Supply 2 fan fault.
BE820173 Power Supply 2 thermal fault.
BE820174 Power supply unit (PSU) 2, DC over voltage.
BE820175 Power supply unit (PSU) 2, DC under voltage.
BE820176 Power supply unit (PSU) 2, DC over current.
BE820177 VCO unit 2, DC under voltage.
BE820178 Power Supply 2 current share warning.
BE820179 Power supply unit (PSU) 2, DC fail.
BE820180 Only RAID controller C1 received PCIe power down request.
BE820181 Unexpected firmware trap.
BE820183 Watchdog timer trip.
BE820186 Power supply unit (PSU) 1, AC fail.
BE820187 Power supply unit (PSU) 2, AC fail.
BE820188 Only RAID controller C2 received PCIe power down request.
BE820189 Storage enclosure statesave complete.
BE82018A Storage enclosure statesave threshold exceeded.
BE820200 ESM VPD checksum failed.
BE820201 Midplane VPD checksum failed.
BE820202 Feature code check failed.
BE820203 VPD migration failed.
BE820204 I2C check failed.
BE820205 Power supply failed.
BE820206 Hot plug controller check failed.
BE820207 Regulator test failed.
BE820208 Fan test failed.
BE820209 Expander clock failed.
BE82020A Internal RAM check failed.
BE82020B ESM VPD check failed.
BE82020C Midplane VPD check failed.
BE82020D I2C check failed.
BE82020E PCI Repeaters check failed.
BE82020F SAS Repeaters check failed.
BE820210 PSoc SGPIO failed.
BE820272 Over temperature, warning threshold exceeded.
BE820296 Over temperature, critical threshold exceeded.
BE820300 PHY Link not ready.
BE820301 PHY Adapt Timer expired.
BE820302 PHY Link not stable.
BE82CD01 Power supply unit (PSU) 1, DC over voltage.
BE82CD02 Power supply unit (PSU) 1, DC under voltage.
BE82CD03 Power supply unit (PSU) 1, DC over current.
BE82CD05 Power supply unit (PSU) 1 powered off unexpectedly.
BE82CD07 Power supply unit (PSU) 1, AC fail.
BE82CD08 Power supply unit (PSU) 1, DC fail.
BE82CD09 Power supply unit (PSU) 1, fan 1 failure.
BE82CD0A Power supply unit (PSU) 1, fan 2 failure.
BE82CD0B Power supply unit (PSU) 1, fan 3 failure.
BE82CD0C Power supply unit (PSU) 1, fan 4 failure.
BE82CD0D Power supply unit (PSU) 1, fan 5 failure.
BE82CD0E Power supply unit (PSU) 1, fan 6 failure.
BE82CD0F Power supply unit (PSU) 1, fan 7 failure.
BE82CD10 Power supply unit (PSU) 1, fan 8 failure.
BE82CD11 Power supply unit (PSU) 2, DC over voltage.
BE82CD12 Power supply unit (PSU) 2, DC under voltage.
BE82CD13 Power supply unit (PSU) 2, DC over current.
BE82CD15 Power supply unit (PSU) 2 powered off unexpectedly.
BE82CD17 Power supply unit (PSU) 2, AC fail.
BE82CD18 Power supply unit (PSU) 2, DC fail.
BE82CD19 Power supply unit (PSU) 2, fan 1 failure.
BE82CD1A Power supply unit (PSU) 2, fan 2 failure.
BE82CD1B Power supply unit (PSU) 2, fan 3 failure.
BE82CD1C Power supply unit (PSU) 2, fan 4 failure.
BE82CD1D Power supply unit (PSU) 2, fan 5 failure.
BE82CD1E Power supply unit (PSU) 2, fan 6 failure.
BE82CD1F Power supply unit (PSU) 2, fan 7 failure.
BE82CD20 Power supply unit (PSU) 2, fan 8 failure.
BE82CD21 Over temperature, warning threshold exceeded.
BE82CD22 Over temperature, critical threshold exceeded.
BE82CD23 Under temperature, warning threshold exceeded.
BE82CD24 Under temperature, critical threshold exceeded.
BE82CD4D Intra enclosure services manager (ESM) communication fails on both paths.
BE82CD4E Enclosure services manager (ESM) VPD read failure.
BE82CD4F Miscompare detected between enclosure midplane VPD and enclosure services manager (ESM) VPD.
BE82CD50 Intra enclosure services manager (ESM)communication fails on both paths.
BE82CD51 Enclosure services manager(ESM)VPD read failure.
BE82CD52 Miscompare detected between enclosure midplane VPD and enclosure services manager (ESM) VPD.
BE82CD55 Enclosure services manager (ESM) 1 voltage sensor reading above/below thresholds - (3.3v OV)
BE82CD56 Enclosure services manager (ESM) 1 voltage sensor reading above/below thresholds - (3.3v UV)
BE82CD59 Enclosure services manager (ESM) 1 voltage sensor reading above/below thresholds - (1.0v OV)
BE82CD5A Enclosure services manager (ESM) 1 voltage sensor reading above/below thresholds - (1.0v UV)
BE82CD5D Enclosure services manager (ESM) 1 voltage sensor reading above/below thresholds - (1.8v OV)
BE82CD5E Enclosure services manager (ESM) 1 voltage sensor reading above/below thresholds - (1.8v UV)
BE82CD61 Enclosure services manager (ESM) 1 voltage sensor reading above/below thresholds - (0.92v OV)
BE82CD62 Enclosure services manager (ESM) 1 voltage sensor reading above/below thresholds - (0.92v UV)
BE82CD65 Enclosure services manager (ESM) 2 voltage sensor reading above/below thresholds - (3.3v OV)
BE82CD66 Enclosure services manager (ESM) 2 voltage sensor reading above/below thresholds - (3.3v UV)
BE82CD69 Enclosure services manager (ESM) 2 voltage sensor reading above/below thresholds - (1.0v OV)
BE82CD6A Enclosure services manager (ESM) 2 voltage sensor reading above/below thresholds - (1.0v UV)
BE82CD6D Enclosure services manager (ESM) 2 voltage sensor reading above/below thresholds - (1.8v OV)
BE82CD6E Enclosure services manager (ESM) 2 voltage sensor reading above/below thresholds - (1.8v UV)
BE82CD71 Enclosure services manager (ESM) 2 voltage sensor reading above/below thresholds - (0.92v OV)
BE82CD72 Enclosure services manager (ESM) 2 voltage sensor reading above/below thresholds - (0.92v UV)
BE82CD73 Enclosure services manager (ESM) 1 failure to read enclosure midplane VPD 1.
BE82CD74 Enclosure services manager (ESM) 2 failure to read enclosure midplane VPD 1.
BE82CD75 Enclosure services manager (ESM) 1 failure to read enclosure midplane VPD 2.
BE82CD76 Enclosure services manager (ESM) 2 failure to read enclosure midplane VPD 2.
BE82CD77 Complex Programmable Logic Device (CPLD) failure on enclosure services manager (ESM) 1
BE82CD78 Complex Programmable Logic Device (CPLD) failure on enclosure services manager (ESM) 2
BE82CD79 Degraded SAS link reported on port T1 of enclosure services manager (ESM) 1.
BE82CD7A Degraded SAS link reported on port T2 of enclosure services manager (ESM) 1.
BE82CD7B Degraded SAS link reported on port T3 of enclosure services manager (ESM) 1.
BE82CD7C Degraded SAS link reported on port T1 of enclosure services manager (ESM) 2.
BE82CD7D Degraded SAS link reported on port T2 of enclosure services manager (ESM) 2.
BE82CD7E Degraded SAS link reported on port T3 of enclosure services manager (ESM) 2.
BE82CD80 Enclosure services manager (ESM) 1 reports communication failure with power supply unit (PSU) 1.
BE82CD81 Enclosure services manager (ESM) 2 reports communication failure with power supply unit (PSU) 1.
BE82CD82 Enclosure services manager (ESM) 1 reports communication failure with power supply unit (PSU) 2.
BE82CD83 Enclosure services manager (ESM) 2 reports communication failure with power supply unit (PSU) 2.
Table 3. BE83xxxx System Reference Codes
System Reference Code Description
BE83CB81 Storage enclosure RAID controller unit check error detected.
BE83CB82 Device adapter unit check data error.
BE83CB83 Device adapter reset timeout.
BE83CB84 Device adapter not available because of a firmware error.
BE83CB85 Device adapter command timeout.
BE83CB86 Device adapter ISR unexpected reset error in last path.
BE83CB87 Device adapter ISR unexpected reset error.
BE83CB88 Device adapter ISR generic error.
BE83CB89 Device adapter reset timeout.
BE83CB8A Device adapter HCAM mechanism failure.
BE83CB8B Device adapter configuration HCAM overflow.
BE83CB8C Device adapter general ASM error.
BE83CB8D Device adapter ASM firmware download error.
BE83CB8E Device adapter ISR unrecoverable hardware error.
BE83CB93 Device adapter user requested reset reached threshold, adapter fenced.
BE83CB94 Device adapter I/O command has timed out.
BE83CB98 SIS adapter has detected an IOCTL watchdog timeout condition.
BE83CB9B SIS adapter requested reset to collect dump.
BE83CBB1 Storage enclosure RAID controller firmware image on the LPAR is missing or corrupted.
BE83CBB2 Storage enclosure RAID controller not available as a hot standby.
BE83CBB5 Storage enclosure RAID controller generic problem detected by device adapter (DA) microcode.
BE83CBB6 Storage enclosure RAID controller heartbeat timeout detected by device adapter (DA) microcode.
BE83CBB8 Storage enclosure RAID controller slow drive timeout detected by device adapter (DA) microcode.
BE83CBB9 Storage enclosure RAID controller detected DMA failure.
BE83CBBA A DMA operation, while operating in a DA failover condition, did not complete successfully.
BE83CBBE Storage enclosure RAID controller I/O command has taken an unexpectedly long duration.
BE83CBC3 The device adapter cards reported the storage enclosure drives failed the secure data overwrite process for customer data drives.
Table 4. BE84xxxx System Reference Codes
System Reference Code Description
BE840054 Drive was marked for deferred sparing.
BE840055 Drive install certify failed due to microcode logic error
BE840056 Unexpected number of drives within the same adapter reported as failed.