BEDxxxxx

This section lists the BEDxxxxx system reference codes.

If the SRC listed in a serviceable event is missing from the following table, ask your next level of support for assistance.
Note: Next level, inform development of any SRCs not defined in the table.
Table 1. BED0xxxx System Reference Codes
System Reference Code Description
BED00000 Reported Product Data (MRPD) - expected resources were not found.
BED00001 Machine Reported Product Data (MRPD) - detected resource manager (RM) error.
BED00002 Machine Reported Product Data (MRPD) - detected microcode logic error.
BED00003 Machine Reported Product Data (MRPD) - detected subsystem not in expected state.
BED00004 Machine Reported Product Data (MRPD) - detected invalid managed system MTMS.
BED00005 Machine Reported Product Data (MRPD) - detected unknown error.
BED00100 Health check detected possible CEC LPAR memory error.
BED00101 Health check detected possible CEC LPAR processor error.
Table 2. BED1xxxx System Reference Codes
System Reference Code Description
BED10110 Trailing port status failure has occurred on the power controlling CEC.
BED10120 Trailing port status failure has occurred on the local I/O Enclosure.
BED10130 Trailing port status failure has occurred on the remote CEC.
BED10140 Trailing port status failure has occurred on the remote I/O Enclosure.
BED10150 Invalid trailing port status returned by Phyp code to RAS code.
BED10160 RIO trailing port status failure.
BED10210 Leading port status failure has occurred on the power controlling CEC.
BED10220 Leading port status failure has occurred on the local I/O Enclosure.
BED10230 Leading port status failure has occurred on the remote CEC.
BED10240 Leading port status failure has occurred on the remote I/O Enclosure.
BED10250 Invalid leading port status returned by Phyp code to RAS code.
BED10260 RIO port status failure.
BED10310 Leading port speed failure has occurred on the power controlling CEC.
BED10320 Leading port speed failure has occurred on the local I/O Enclosure.
BED10330 Leading port speed failure has occurred on the remote CEC.
BED10340 Leading port speed failure has occurred on the remote I/O Enclosure
BED10350 Invalid leading port speed returned by Phyp code to RAS code.
BED10360 RIO port speed failure.
BED10410 Power controlling CEC enclosure SPCN MTMS VPD error due to incorrect cabling.
BED10411 Power controlling CEC enclosure read invalid SPCN MTMS VPD. 'UTMP' value found.
BED10412 Power controlling CEC enclosure cannot read SPCN MTMS VPD. 'null' value found.
BED10420 Local I/O enclosure SPCN MTMS VPD error due to incorrect cabling.
BED10421 Local I/O enclosure read invalid SPCN MTMS VPD.
BED10422 Local I/O cannot read SPCN MTMS VPD.
BED10430 Remote CEC enclosure SPCN MTMS VPD error due to incorrect cabling.
BED10431 Remote CEC enclosure read invalid SPCN MTMS VPD.
BED10432 Remote CEC enclosure cannot read SPCN MTMS VPD.
BED10440 Remote I/O enclosure SPCN MTMS VPD error due to incorrect cabling.
BED10441 Remote I/O enclosure read invalid SPCN MTMS VPD.
BED10422 Remote I/O enclosure cannot read SPCN MTMS VPD.
BED10450 Invalid SPCN MTMS VPD returned by Phyp code to RAS code.
BED10460 Incorrect Power Controlling CEC enclosure VPD Found.
BED10470 Incomplete SPCN loop found on CEC XX
BED10510 Leading port type failure has occurred on the power controlling CEC.
BED10520 Leading port type failure has occurred on the local I/O enclosure.
BED10530 Leading port type failure has occurred on the remote CEC.
BED10540 Leading port type failure has occurred on the remote I/O enclosure.
BED10550 Invalid leading port type returned by Phyp code to RAS code.
BED10610 Power controlling CEC enclosure RIO leading port VPD failure due to incorrect cabling.
BED10611 Power controlling CEC enclosure read invalid RIO leading port VPD. UTMP value found.
BED10612 Power controlling CEC enclosure cannot read RIO leading port VPD.
BED10620 Local I/O enclosure RIO leading port VPD failure due to incorrect cabling.
BED10621 Local I/O enclosure read invalid RIO leading port VPD. UTMP value found.
BED10622 Local I/O enclosure cannot read RIO leading port VPD.
BED10630 Remote CEC enclosure RIO leading port VPD failure due to incorrect cabling.
BED10631 Remote CEC enclosure read invalid RIO leading port VPD. UTMP value found.
BED10632 Remote CEC enclosure read invalid RIO leading port VPD. UTMP value found.
BED10640 Remote I/O enclosure RIO leading port VPD failure due to incorrect cabling.
BED10650 Invalid RIO leading port VPD returned by PHYP code to RAS code.
BED10660 Incorrect Leading Port VPD Found.
BED10710 Power controlling CEC enclosure RIO trailing port VPD failure due to incorrect cabling.
BED10711 Power controlling CEC enclosure read invalid RIO trailing port VPD. UTMP value found.
BED10712 Power controlling CEC enclosure cannot read RIO trailing port VPD.
BED10720 Local I/O enclosure RIO trailing port VPD failure due to incorrect cabling.
BED10721 Local I/O enclosure read invalid RIO trailing port VPD.
BED10722 Local I/O enclosure cannot read RIO trailing port VPD.
BED10730 Remote CEC enclosure RIO trailing port VPD failure due to incorrect cabling.
BED10731 Remote CEC enclosure read invalid RIO trailing port VPD.
BED10732 Remote CEC enclosure cannot read RIO trailing port VPD.
BED10740 Remote I/O enclosure RIO trailing port VPD failure due to incorrect cabling.
BED10741 Remote I/O enclosure read invalid RIO trailing port VPD.
BED10742 Remote I/O enclosure cannot read RIO trailing port VPD.
BED10750 Invalid RIO trailing port VPD returned by PHYP code to RAS code.
BED10760 Incorrect Trailing Port VPD Found
BED10800 CEC or I/O enclosure power supply 1 fault.
BED10801 CEC or I/O enclosure power supply 2 fault.
BED10802 CEC enclosure fan 1 fault.
BED10803 CEC enclosure fan 2 fault.
BED10804 Internal error calling rsMMgetPowerFaultStatus.
BED10805 CEC or I/O enclosure power supply 1 not detected.
BED10806 CEC or I/O enclosure power supply 2 not detected.
BED10807 CEC enclosure fan 1 not detected.
BED10808 CEC enclosure fan 2 not detected.
BED10810 Power controlling CEC enclosure read RIO VPD but it is out of order due to incorrect cabling.
BED10811 Power controlling CEC enclosure read invalid RIO VPD. UTMP value found.
BED10812 Unable to read the power controlling CEC RIO VPD.
BED10813 CEC enclosure fan 3 fault.
BED10814 CEC enclosure fan 4 fault.
BED10815 CEC enclosure fan 3 not detected.
BED10816 CEC enclosure fan 4 not detected.
BED10817 CEC enclosure fan 5 fault.
BED10818 CEC enclosure fan 6 fault.
BED10820 Local I/O enclosure read RIO VPD but it is out of order due to incorrect cabling.
BED10821 Local I/O enclosure read invalid RIO VPD.
BED10822 Unable to read local I/O RIO VPD.
BED10823 CEC enclosure fan 5 not detected.
BED10824 CEC enclosure fan 6 not detected.
BED10825 CEC or I/O enclosure power supply 3 fault.
BED10826 CEC or I/O enclosure power supply 4 fault.
BED10827 CEC or I/O enclosure power supply 3 not detected.
BED10828 CEC or I/O enclosure power supply 4 not detected.
BED10830 Remote CEC enclosure read RIO VPD but it is out of order due to incorrect cabling.
BED10831 Remote CEC enclosure read invalid RIO VPD.
BED10832 Unable to read the Remote CEC enclosure RIO VPD.
BED10833 CEC enclosure fan 7 fault.
BED10834 CEC enclosure fan 8 fault.
BED10835 CEC enclosure fan 9 fault.
BED10836 CEC enclosure fan 7 not detected.
BED10837 CEC enclosure fan 8 not detected.
BED10838 CEC enclosure fan 9 not detected.
BED10840 Remote I/O enclosure read RIO VPD but it is out of order due to incorrect cabling.
BED10841 Remote I/O enclosure read invalid RIO VPD.
BED10842 Unable to read the Remote I/O enclosure RIO VPD.
BED10850 Invalid enclosure type returned by PHYP code to RAS code.
BED10860 Incorrect Enclosure VPD Found
BED10910 Tower is not running in MultiHub mode.
BED10920 RIO tower cpssbayXX is missing from RIO Topology on CEC XX.
BED10970 Found failed RIO card on tower.
BED10980 Found failed CEC enclosure RIO card.
BED10985 Found failed I/O Planar on CEC.
BED10990 Found failed CEC.
BED13111 Fan assembly (A1) intake fan error reported by E31 during a status request.
BED13112 Fan assembly (A1) exhaust fan error reported by E31 during a status request.
BED13121 Fan assembly (A2) intake fan error reported by E31 during a status request.
BED13122 Fan assembly (A2) exhaust fan error reported by E31 during a status request.
BED13211 Fan assembly (A1) intake fan error reported by E32 during a status request.
BED13212 Fan assembly (A1) exhaust fan error reported by E32 during a status request.
BED13221 Fan assembly (A2) intake fan error reported by E32 during a status request.
BED13222 Fan assembly (A2) exhaust fan error reported by E32 during a status request.
Table 3. BED2xxxx System Reference Codes
System Reference Code Description
BED20011 Laptop external cooling Fan 1 reporting one failing impeller.
BED20012 Laptop external cooling Fan 1 reporting two failing impellers.
BED20021 Laptop external cooling Fan 2 reporting one failing impeller.
BED20022 Laptop external cooling Fan 2 reporting two failing impellers.
BED20031 Laptop external cooling Fan 3 reporting one failing impeller.
BED20032 Laptop external cooling Fan 3 reporting two failing impellers.
BED20041 Laptop external cooling Fan 4 reporting one failing impeller.
BED20042 Laptop external cooling Fan 4 reporting two failing impellers.