(DAxxxxxx) Partition firmware reference (error) codes
The partition firmware detected a failure. The first eight characters in the display represent the SRC. Any additional characters represent the associated location code. Record the location code as well as the reference code, then find the SRC in Table 1.
If you do not find an SRC in the table that follows, contact your
next level of support for assistance.
Notes:
- The SRCs on this page are from the Power Systems hardware documentation, and the Descriptions apply to a single CEC enclosure or I/O enclosure. The Action and Failing Item fields are modified as appropriate for DS8000® architecture and repair methods.
- SRCs missing from the following tables might be found on the Power Systems online documentation. You can use the SRC description
as is
to define the problem. Do not use the Action and Failing Item without contacting the next level of support first. - To display the Power Systems hardware
online documentation, go to the Web site http://www-01.ibm.com/support/knowledgecenter/.
- In the IBM Systems Hardware Information right content pane, click POWER6 reference codes listing.
| SRC | Description/Action | Failing item |
|---|---|---|
| DA080001 | An IDE device remained busy for a longer period than the time-out period. | FWFWPBL |
| DA080002 | The IDE controller senses IDE devices but with errors.
|
|
| DA080010 | An IDE device is busy longer than specified time-out
period. Retry the operation. |
FWIDE1 |
| DA080011 | An IDE command timed out; command is exceeding the period
allowed to complete. Retry the operation. |
FWIDE1 |
| DA080012 | The ATA command failed. | FWIDE2 |
| DA080013 | The media is not present in the tray. Retry the operation. |
FWIDE1 |
| DA080014 | The media has been changed. Retry the operation. |
FWIDE1 |
| DA080015 | The packet command failed; the media might not be readable. Retry the operation. |
FWIDE1 |