(E302xxxx) Licensed Internal Code error codes
For use by service providers.
The Hardware Management Console generates E302xxxx error codes when it encounters a problem during an update of the firmware for the managed system.
- The SRCs on this page are from the Power Systems hardware documentation, and the Descriptions apply to a single CEC enclosure or I/O enclosure. The Action and Failing Item fields are modified as appropriate for DS8000® architecture and repair methods.
- SRCs missing from the following tables might be found on the Power Systems online documentation. You can use the SRC description
as is
to define the problem. Do not use the Action and Failing Item without contacting the next level of support first. - To display the Power Systems hardware
online documentation, go to the Web site http://www-01.ibm.com/support/knowledgecenter/.
- In the IBM Systems Hardware Information right content pane, click POWER6 reference codes listing.
| SRC | Description/Action | Failing Item |
|---|---|---|
| E302F800 | An error occurred while attempting to create a provider
instance of the service processor interface code as a PIHSCCECCIMClient.
An exception was thrown from the PIHSCCECCIMClient createInstance code. Go to the Server and Partition display, refresh the screen and ensure the system is in a good state (for example, power off, standby, or operating). Then repeat the operation. |
NEXTLVL |
| E302F801 | An error occurred while attempting to find one of the
directories used to store data for the firmware update application. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F802 | The survey from the repository method was called, but the repository selected
was not the IBM® support system, the IBM website, the DVD, or the hard drive. Use the HMC graphical user interface (GUI) to reselect the source for code updates, and then retry the update. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F803 | The survey from an FTP site failed when downloading the list of files from the
FTP repository failed. Verify that you correctly entered valid values for the FTP site, user, password, and directory. Then, repeat the operation. |
NEXTLVL |
| E302F804 | The request to get a list of IBM support system fix packs failed because the request timed out. Verify that the HMC is properly configured to communicate with the IBM support system. Verify that the IBM support system accepted the administrative information for your HMC, and then repeat the operation. Verify that you correctly entered valid values for the FTP site, user, password, and directory. Then, repeat the operation. |
NEXTLVL |
| E302F805 | The request to get a list of IBM support system fix packs failed with an exception. Repeat the operation. If it fails, call your next level of support. |
NEXTLVL |
| E302F806 | The request to get a list of IBM support system fix packs failed with an error code. Repeat the operation. If it fails, call your next level of support. |
NEXTLVL |
| E302F807 | No phone server was available to service the request to get a list of IBM
support system fix packs. Ensure that your connection to the IBM support system is set up correctly and repeat the operation. |
NEXTLVL |
| E302F808 | The list of fix packs was retrieved from the IBM
support system, but an I/O exception occurred when the list was written to the hard file.
Reboot the HMC and retry the operation. If it fails again, consider replacing the disk drive in the HMC. |
NEXTLVL |
| E302F809 | An error occurred while attempting to run the code to get the service processor
to run a query, or set, the current IPL side or the next IPL side. Go to the Server and Partition display, refresh the screen and ensure that the system is in a good state (for example, power off, standby, or operating). Then, repeat the operation. |
NEXTLVL |
| E302F80A | An invalid object was used while attempting to create
an owner for the update. Something is wrong with the selected target. Reboot the HMC and retry the operation. If the problem persists contact your next level of support. |
NEXTLVL |
| E302F80B | Unable to get the name of the HMC while preparing to create
a service processor client. Reboot the HMC and retry the operation. If it fails again, contact your next level of support. |
NEXTLVL |
| E302F80C | Failure when attempting to read a file. Reboot the HMC and retry the operation. If it fails again, consider replacing the disk drive of the HMC. |
NEXTLVL |
| E302F80D | Failure when attempting to close a file. Reboot the HMC and retry the operation. If it fails again, consider replacing the disk drive of the HMC. |
NEXTLVL |
| E302F80E | The list of fix packs was retrieved from the IBM
system, but an I/O
exception occurred when closing the list that was written to the hard file. Reboot the HMC and retry the operation. If it fails again, consider replacing the disk drive of the HMC. |
NEXTLVL |
| E302F80F | The method to import the stageable cover letter was called, but the repository
selected was not the IBM support system, the IBM website,, the DVD, or the hard drive. Use the HMC GUI to reselect the source for code updates, and then retry the update. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F810 | Unable to FTP the cover letter from the specified repository
to the staging area. Verify that the FTP site is still up, and then retry the operation. |
NEXTLVL |
| E302F811 | The request to get cover letter from
the IBM support
system timed out. Verify that your connection to the IBM support system is set up correctly and is operational. Retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F812 | The request to get cover letter from
the IBM support
system failed with
an exception. Verify that your connection to the IBM support system is set up correctly and is operational. Retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F813 | The request to get cover letter from
the IBM support
system failed with
an error code. Verify that your connection to the IBM support system is set up correctly and is operational. Retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F814 | No phone server was available to service the request to
get cover letters from the IBM support system. Configure the HMC as a phone server and retry the operation. |
NEXTLVL |
| E302F815 | Failure when attempting to copy the cover
letter from the DVD to the staging
area on the hard file. The CD or DVD might be faulty. Try another one. |
NEXTLVL |
| E302F816 | An error occurred when attempting to get the service processor
to run a query of its state. Go to the Server and Partition display, refresh the screen and ensure the system is in a good state (for example, power off, standby, or operating). Then repeat the operation. |
NEXTLVL |
| E302F817 | A query of the current IPL side returned a null. Go to the Server and Partition display, refresh the screen and ensure the system is in a good state (for example, power off, standby, or operating). Then repeat the operation. |
NEXTLVL |
| E302F818 | A query of the next IPL side returned a null. Go to the Server and Partition display, refresh the screen and ensure the system is in a good state (for example, power off, standby, or operating). Then repeat the operation. |
NEXTLVL |
| E302F819 | A query of the current IPL side failed. Go to the Server and Partition display, refresh the screen and ensure the system is in a good state (for example, power off, standby, or operating). Then repeat the operation. |
NEXTLVL |
| E302F81A | An exception occurred during a query of the current IPL
side. Go to the Server and Partition display, refresh the screen and ensure the system is in a good state (for example, power off, standby, or operating). Then repeat the operation. |
NEXTLVL |
| E302F81B | A query of the next IPL side failed. Go to the Server and Partition display, refresh the screen and ensure the system is in a good state (for example, power off, standby, or operating). Then repeat the operation. |
NEXTLVL |
| E302F81C | An exception occurred during a query of the next IPL side. Go to the Server and Partition display, refresh the screen and ensure the system is in a good state (for example, power off, standby, or operating). Then repeat the operation. |
NEXTLVL |
| E302F81D | Failure during an attempt to copy the cover letter from the
IBM website to the staging area on the hard file.
Reboot the HMC. Verify that your LAN connection is set up properly. Then retry the operation. |
NEXTLVL |
| E302F81E | Failure of a survey from an FTP site occurred when
a connection to the site was unavailable. Ensure that the FTP site is reachable on the network from the HMC and that the site is up and running properly. Ensure that all firewall authentications are successfully performed if needed, and then retry the operation. |
NEXTLVL |
| E302F81F | Failure of a survey from an FTP site occurred when
logging into the site was unsuccessful. Ensure that the login parameters are correct, and then retry the operation. |
NEXTLVL |
| E302F820 | An error occurred while attempting to read the common
marker firmware update file from flash memory to the hard file. Go to the Server and Partition display, refresh the screen and ensure the system is in a good state (for example, power off, standby, or operating). Then repeat the operation. If the problem occurs again contact your next level of support. |
NEXTLVL |
| E302F821 | An error occurred while attempting to read the common
marker firmware update file from the hard file into memory. Reboot the HMC and retry the operation. If the problem occurs again contact your next level of support. |
NEXTLVL |
| E302F822 | An error occurred while attempting to find one of the
directories used to store data for the firmware update application. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F828 | An error occurred while attempting to read the master
firmware update file from flash memory to the hard drive. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F829 | An error occurred while attempting to read the master
firmware update file from the hard drive into memory. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F82A | An error occurred while attempting to read the header
of the master firmware update file from flash memory to the hard file. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F82B | An error occurred while attempting to find one of the
directories used to store data for the firmware update application. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F82C | An error occurred while attempting to create a provider
instance of the secondary service processor interface code as a PIHSCCECCIMClient.
An exception was thrown from the PIHSCCECCIMClient createInstance code. Go to the Server and Partition display, refresh the screen and ensure that the system is in a good state (power off, standby, or power on). Then repeat the operation. |
NEXTLVL |
| E302F830 | An error occurred while attempting to read a flash firmware
update file from the hard file into memory. Reboot the HMC and try the operation again. If the problem occurs again, consider replacing the disk drive of the HMC. |
NEXTLVL |
| E302F831 | A file that was supposed to be a firmware update file
either does not exist or is too small to contain a valid header. If you are using nondisruptive microcode, verify that your test firmware update files are correct. Otherwise contact your next level of support. |
NEXTLVL |
| E302F838 | An error occurred while attempting to read the information about the fix pack out of the cover letter.
Verify that the cover letter is correct and has not been corrupted. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F840 | An error occurred while attempting to get the engineering
change streams in order to retrieve all of the updates from removable media. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F841 | An error occurred while attempting to issue a start code update command to the
master service processor. Manually point the next FSP re-IPL to the P side using the Flash Side Selection panels. Then, perform a "Disruptive activate" using the Select advanced features panels. Try the operation again. If the problem recurs, contact your next level of support. |
NEXTLVL |
| E302F842 | An error occurred while attempting to issue a write firmware update file command
to the master service processor. Manually point the next FSP re-IPL to the P side using the Flash Side Selection panels. Then, perform a "Disruptive activate" using the Select advanced features panels. Try the operation again. If the problem recurs, contact your next level of support. |
NEXTLVL |
| E302F843 | An error occurred while attempting to issue a "code update
complete" action to the master service processor. Try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F844 | An error occurred while attempting to reboot the service
processor Try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F845 | The "import from a remote repository" code routine was called, but the
repository selected was not the IBM support system or the IBM website. Use the HMC GUI to reselect the source for code updates. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F846 | An error occurred while attempting to swap the T and P
sides of the service processor. Try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F847 | An engineering change stream was passed between components,
but no such engineering change stream exists for the targeted object. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F848 | A request to import the IBM support system fix packs and cover
letters timed out. Verify that your connection to the IBM support system is set up correctly and is operational. Retry the operation. If the problem recurs, contact your next level of support. |
NEXTLVL |
| E302F849 | A request to import the IBM support system fix packs and cover
letters failed. Verify that your connection to the IBM support system is set up correctly and is operational. Retry the operation. If the problem recurs, contact your next level of support. |
NEXTLVL |
| E302F84A | Failure during an attempt to read the surveyed list of fix
packs. Reboot the HMC and try the operation again. If the problem occurs again, consider replacing the disk drive of your HMC. |
NEXTLVL |
| E302F84B | Failure during an attempt to close the surveyed list of fix
packs. Reboot the HMC and try the operation again. If the problem occurs again, consider replacing the disk drive of your HMC. |
NEXTLVL |
| E302F84C | An error occurred while attempting to get the engineering
change streams in order to list all of the updates available on the removable
media. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F84D | An error occurred while trying to copy the RPM files from
the media repository to the hard file. The CD or DVD might be faulty. Try another one. |
NEXTLVL |
| E302F84E | An error occurred in a removable media code routine because
the file types were null. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F84F | An error occurred in a method because one of the file
arrays had a length of zero. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F850 | A failure occurred while trying to unpack the RPM file
in the "complete concurrently" code routine. Reboot the HMC and try the operation again. In the HMC code released before August 2004, there was a problem that can be corrected with commands from the Linux command line as follows: ls -l /opt/ccfw/data/*.rpmrpm -e rpm packagename |
NEXTLVL |
| E302F851 | The request to retrieve fix packs from the IBM support system failed with an error code. Verify that your connection to the IBM support system is set up correctly and is operational. Retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F852 | No phone server was available to serve the request to retrieve IBM
support system fix packs. Configure the HMC as a phone server and retry the operation. |
NEXTLVL |
| E302F853 | An error occurred while attempting to find the directory
where firmware update files are stored for testing with the non disruptive
application panel. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F854 | An error occurred while attempting to issue a read firmware
update file command to a service processor Try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F855 | Importing from an FTP site failed when the files from
the FTP repository were not retrieved. Try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F856 | A failure occurred when trying to query the name of the
image in the RPM file. Try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F857 | A failure occurred while attempting to issue the runact
API. Try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F858 | An exception occurred while attempting to issue the runact
API. Try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F859 | An exception occurred while trying to query the name of
the image in the RPM file. Try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F85A | An exception occurred while trying to unpack the RPM file
in the "complete concurrently" code routine. Try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F85B | An exception occurred while trying to import updates from
the DVD. The CD or DVD might be faulty. Try another one. |
NEXTLVL |
| E302F85C | An error occurred while attempting to copy the T side
to the P side. In the Licensed Internal Code Update panels, choose Select advanced features, and then choose Accept to copy the T side to the P side. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F85D | An error occurred while attempting to IPL the system unit. The level of code requested is most likely activated on the targeted system. Verify the activated level through System Information. Then IPL the system unit if desired. |
NEXTLVL |
| E302F85E | An error occurred while attempting to power on the system
unit. The level of code requested is most likely activated on the targeted system. Verify the activated level through System Information. Then power on the system unit if desired. |
NEXTLVL |
| E302F85F | An error occurred while attempting to power off the system
unit. Try powering off the system unit manually and doing the code update while the system is in the platform standby state. |
NEXTLVL |
| E302F860 | An error occurred while trying to import updates to the
DVD during an export command. The CD or DVD might be faulty. Try another one. |
NEXTLVL |
| E302F861 | An error occurred while attempting to open the hypervisor
diff file prior to writing. The level of code requested is most likely activated on the targeted system, but not loaded into the server firmware. Verify the activated level through System Information. If the activated level is what is expected, schedule a time to IPL the system. |
NEXTLVL |
| E302F862 | An error occurred while attempting to write the hypervisor
diff file to the hypervisor. The level of code requested is most likely activated on the targeted system, but not loaded into the server firmware. Verify the activated level through System Information. If the activated level is what is expected, schedule a time to IPL the system. |
NEXTLVL |
| E302F863 | An error occurred while attempting to close the hypervisor
firmware diff file after writing it to the server firmware. The level of code requested is most likely activated on the targeted system, but not loaded into the hypervisor. Verify the activated level through System Information. If the activated level is what is expected, schedule a time to IPL the system. |
NEXTLVL |
| E302F864 | An exception occurred during the query to see if a hypervisor
firmware update has completed. The level of code requested is most likely activated on the targeted system, but not loaded into the hypervisor. Verify the activated level through System Information. If the activated level is what is expected, schedule a time to IPL the system. |
NEXTLVL |
| E302F865 | A failure occurred while querying the status after a firmware
update. The level of code requested is most likely activated on the targeted system, but not loaded into the server firmware. Verify the activated level through System Information. If the activated level is what is expected, schedule a time to IPL the system. |
NEXTLVL |
| E302F866 | The hypervisor firmware update timed out. The level of code requested is most likely activated on the targeted system, but not loaded into the hypervisor. Verify the activated level through System Information. If the activated level is what is expected, schedule a time to IPL the system. |
NEXTLVL |
| E302F867 | An interruption occurred while waiting for the hypervisor
firmware update. The level of code requested is most likely activated on the targeted system, but not loaded into the hypervisor. Verify the activated level through System Information. If the activated level is what is expected, schedule a time to IPL the system. |
NEXTLVL |
| E302F868 | An error occurred while issuing a start code update command
to the secondary service processor. The secondary service processor will be synchronized in the next code update. If this does not occur, contact your next level of support. |
NEXTLVL |
| E302F869 | An error occurred while issuing a write firmware update
file command to the secondary service processor. The secondary service processor will be synchronized in the next code update. If this does not occur, contact your next level of support. |
NEXTLVL |
| E302F86A | An error occurred issuing a code update complete command
to the secondary service processor. The secondary service processor will be synchronized in the next code update. If this does not occur, contact your next level of support. |
NEXTLVL |
| E302F86B | A failure occurred while issuing a runact API to query
the partitions and their status. The level of code requested is most likely activated on the targeted system, but not loaded into the server firmware. Verify the activated level through System Information. If the activated level is what is expected, schedule a time to restart the partitions. |
NEXTLVL |
| E302F86C | An exception occurred while issuing a runact API to query
the partitions and their status. The level of code requested is most likely activated on the targeted system, but not loaded into the server firmware. Verify the activated level through System Information. If the activated level is what is expected, schedule a time to restart the partitions. |
NEXTLVL |
| E302F86D | A fix pack did
not contain a diff firmware update file, or no diff firmware update file was found in the firmware
update file directory, for nondisruptive firmware application. The level of code requested is most likely activated on the targeted system, but not loaded into the server firmware. Verify the activated level through System Information. If the activated level is what is expected, schedule a time to IPL the system. |
NEXTLVL |
| E302F86E | An error occurred during a call to a code module while
preparing to write the hypervisor firmware diff file to flash memory. The level of code requested is most likely activated on the targeted system, but not loaded into the hypervisor firmware. Verify the activated level through System Information. If the activated level is what is expected, schedule a time to IPL the system. |
NEXTLVL |
| E302F86F | An error occurred during a call to a code module while
attempting to write the hypervisor firmware diff file to flash memory. The level of code requested is most likely activated on the targeted system, but not loaded into the hypervisor firmware. Verify the activated level through System Information. If the activated level is what is expected, schedule a time to IPL the system. |
NEXTLVL |
| E302F870 | An error occurred during a call to a code module after
writing the hypervisor firmware diff file to flash memory. The level of code requested is most likely activated on the targeted system, but not loaded into the hypervisor firmware. Verify the activated level through System Information. If the activated level is what is expected, schedule a time to IPL the system. |
NEXTLVL |
| E302F871 | An error occurred during the call to start firmware update
to concurrently patch firmware. The level of code requested is most likely activated on the targeted system, but not loaded into the server firmware. Verify the activated level through System Information. If the activated level is what is expected, schedule a time to IPL the system. |
NEXTLVL |
| E302F872 | Querying status after a firmware update did not return
the proper number of elements in the vector. The level of code requested is most likely activated on the targeted system, but not loaded into the server firmware. Verify the activated level through System Information. If the activated level is what is expected, schedule a time to IPL the system. |
NEXTLVL |
| E302F873 | Rebooting the service processor was executed, but the
system unit did not return to the state where the T side was active within
a reasonable amount of time. This generally means that the system was not
successful when coming up with the new code level and went back to the older
code level Retry the operation. To do this, select Select Advanced Features and then select Install And Activate. If the code update fails again, contact your next level of support. |
NEXTLVL |
| E302F874 | Rebooting the service processor was executed, but the
system unit did not return to its original state within a reasonable amount
of time. Go to the Server and Partition display, refresh the screen and ensure the system is in a good state (for example, power off, standby, or operating). If it is not in a good state, and then take the necessary steps to put it in a good state. After it is in a good state, check System Information to ensure the code update was applied. If it is now in a good state but the update is not applied, repeat the operation. |
NEXTLVL |
| E302F875 | An error occurred while attempting to query (at standby)
in an attempt to retrieve all of the updates from the removable media. The CD or DVD might be faulty. Try another one. |
NEXTLVL |
| E302F876 | A failure occurred while trying to query the name of the
image in the RPM file. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F877 | An exception occurred while trying to query the name of
the image in the RPM file. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F878 | A failure occurred trying to erase an RPM file. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F879 | An exception occurred trying to erase an RPM file. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F87A | A failure occurred while trying to change the permissions
of an image file after it had been pulled from an RPM package. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F87B | An exception occurred while trying to change the permissions
of an image file after it had been pulled from an RPM package. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F87C | After the flash write to the primary service processor
was complete, the secondary service processor did not complete operations
within half an hour. The secondary service processor will be synchronized in the next code update. If this does not occur, contact your next level of support. |
NEXTLVL |
| E302F87D | A failure occurred importing I/O microcode. Try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F87E | An IPL of the service processor was executed as part of
a disruptive firmware update, but it did not put the system in its original
state within a reasonable amount of time. Go to the Server and Partition display, refresh the screen and ensure the system is in a good state (for example, power off, standby, or operating). If it is not in a good state, take the necessary steps to put it in a good state. After it is in a good state, check System Information to ensure the code update was applied. |
NEXTLVL |
| E302F87F | Powering off the service processor was executed as part
of a disruptive firmware update, but it did not put the service processor
in a powered off state within a reasonable amount of time. Go to the Server and Partition display, refresh the screen and ensure the system is in a good state (for example, power off, standby, or operating). If it is not in a good state, take the necessary steps to put it in a good state. After it is in a good state, repeat the code update operation. |
NEXTLVL |
| E302F880 | Powering on the service processor was executed as part
of a disruptive firmware update, but it did not put the service processor
in a powered on state within a reasonable amount of time. Go to the Server and Partition display, refresh the screen and ensure the system is in a good state (for example, power off, standby, or operating). If it is not in a good state, take the necessary steps to put it in a good state. After it is in a good state, check System Information to ensure the code update was applied. |
NEXTLVL |
| E302F881 | An IPL was executed as part of a disruptive firmware update,
but the managed system was placed in an error state. If this message occurs, contact your next level of support. |
NEXTLVL |
| E302F882 | A power off was executed as part of a disruptive firmware
update, but the managed system was placed in an error state. If this message occurs, contact your next level of support. |
NEXTLVL |
| E302F883 | A power on was executed as part of a disruptive firmware
update, but the managed system was placed in an error state. If this message occurs, contact your next level of support. |
NEXTLVL |
| E302F884 | The service processor was rebooted during a firmware update,
but it did not put the service processor in a "not connected" state within
a reasonable amount of time. Go to the Server and Partition display, refresh the screen and ensure the system is in a good state (for example, power off, standby, or operating). If it is not in a good state, take the necessary steps to put it in a good state. Once in a good state, check System Information to ensure the code update was applied. If it is now in a good state but the update is not applied, and then repeat the operation. |
NEXTLVL |
| E302F885 | The service processor was rebooted during a firmware update,
which put the service processor in a "not connected" state. However, this
action did not clear the "not connected" state within a reasonable amount
of time. Contact the next level of support for assistance in getting the HMC to communicate with the service processor again. |
NEXTLVL |
| E302F886 | An exception occurred during execution of the synchronous
import program while retrieving code from a repository. If this message occurs, contact your next level of support. |
NEXTLVL |
| E302F887 | An exception occurred during execution of the synchronous
apply staged updates program while applying code from the hard file staging
area. If this message occurs, contact your next level of support. |
NEXTLVL |
| E302F888 | A chsyscfg command was issued to change the next
IPL side, but it failed. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F889 | An exception occurred after a chsyscfg command
was issued to change the next IPL side. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F88A | Powering off the system unit has started. | NEXTLVL |
| E302F88B | Reading of the firmware update files has started. | NEXTLVL |
| E302F88C | Writing of the firmware update files has started. | NEXTLVL |
| E302F88D | Rebooting the service processor has started. | NEXTLVL |
| E302F88E | Powering on the system unit has started. | NEXTLVL |
| E302F88F | Restoring of the firmware update files to the P side has started. | NEXTLVL |
| E302F890 | An error occurred while attempting to find the directory
used as temporary storage. Reboot the HMC and try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F891 | Failure when attempting to import an RPM package from the IBM website. Verify that your LAN connections are set up properly and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F892 | A request was received to take the service processor back
to an earlier level, but it was a concurrent request. This operation can only
be performed disruptively. Reboot the HMC and schedule time for a disruptive update. Retry the operation during that scheduled time. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F893 | A general error occurred while applying code. If another error occurs before this message, follow the action for that error. If this message occurs by itself, contact your next level of support. |
NEXTLVL |
| E302F894 | A general error occurred while processing a hardware upgrade. If another error occurs before this message, follow the action for that error. If this message occurs by itself, contact your next level of support. |
NEXTLVL |
| E302F895 | A general error occurred while committing code. If another error occurs before this message, follow the action for that error. If this message occurs by itself, contact your next level of support. |
NEXTLVL |
| E302F896 | A general error occurred while exporting code to the DVD. If another error occurs before this message, follow the action for that error. If this message occurs by itself, contact your next level of support. |
NEXTLVL |
| E302F897 | A general error occurred while importing code. If another error occurs before this message, follow the action for that error. If this message occurs by itself, contact your next level of support. |
NEXTLVL |
| E302F898 | A general error occurred while rejecting code. If another error occurs before this message, follow the action for that error. If this message occurs by itself, contact your next level of support. |
NEXTLVL |
| E302F899 | An attempt was made to update the hypervisor firmware, but the hypervisor reported that it is already at that level. | NEXTLVL |
| E302F89A | A general error occurred while updating the flash
on a service processor. If another error occurs before this message, follow the action for that error. If this message occurs by itself, contact your next level of support. |
NEXTLVL |
| E302F89B | An error occurred while swapping the T and P sides
of the secondary service processor. The secondary service processor will be synchronized in the next code update. If this does not occur, contact your next level of support. |
NEXTLVL |
| E302F89C | An error occurred while copying the T to the P side
on the secondary service processor. The secondary service processor will be synchronized in the next code update. If this does not occur, contact your next level of support. |
NEXTLVL |
| E302F89D | A failure occurred either writing the firmware to
the bulk power assemblies, or rebooting them after writing the firmware. If another error occurs before this message, follow the action for that error. If this message occurs by itself, contact your next level of support. |
NEXTLVL |
| E302F89E | A failure occurred while trying to erase a file. If another error occurs before this message, follow the action for that error. If this message occurs by itself, contact your next level of support. |
NEXTLVL |
| E302F8A0 | An error occurred while trying to read the list of fix
packs that was surveyed. Reboot the HMC and retry the operation. If the problem occurs again, consider replacing the disk drive of the HMC. |
NEXTLVL |
| E302F8A1 | An error occurred while trying to close the list of fix
packs that was surveyed. Reboot the HMC and retry the operation. If the problem occurs again, consider replacing the disk drive of the HMC. |
NEXTLVL |
| E302F8A2 | An error occurred while attempting to update the server
firmware. Try the operation again. If the error occurs again, contact your next level of support. |
NEXTLVL |
| E302F8A3 | An error occurred while querying to see if the server
firmware diff file is in memory. Try the operation again. If the error occurs again, contact your next level of support. |
NEXTLVL |
| E302F8A4 | An exception occurred while querying to see if the server
firmware diff file is in memory. Try the operation again. If the error occurs again, contact your next level of support. |
NEXTLVL |
| E302F8A5 | An exception occurred while querying to see if the HMC
is the code update owner. Try the operation again. If the error occurs again, contact your next level of support. |
NEXTLVL |
| E302F8A6 | An exception occurred while setting the HMC to be the
code update owner. Try the operation again. If the error occurs again, contact your next level of support. |
NEXTLVL |
| E302F8A8 | Querying to see if the service firmware diff file is in
memory did not return the proper number of elements in the vector. Try the operation again. If the error occurs again, contact your next level of support. |
NEXTLVL |
| E302F8A9 | A general error occurred while rebooting. If another error occurs before this message, follow the action for that error. If this message occurs by itself, contact your next level of support. |
NEXTLVL |
| E302F8D0 | An I/O error occurred while reading the fix pack image. Reboot the HMC and retry the operation. If the problem occurs again, consider replacing the disk drive in the HMC. |
NEXTLVL |
| E302F8D1 | An error occurred while writing a firmware update file that was read from a fix pack to disk. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F8F0 | An error occurred while surveying the IBM website. Verify that your LAN connections are set up properly and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F8F1 | An exception occurred while surveying the IBM website. Verify that your LAN connections are set up properly and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F8F2 | An exception occurred while copying the XML file to the cover letter during
import from the website. Verify that your LAN connections are set up properly and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F8F3 | Two hour wait period exceeded for the updating of
firmware on the service processor in the bulk power assembly. If another error occurs before this message, follow the action for that error. If this message occurs by itself, contact your next level of support. |
NEXTLVL |
| E302F900 | The survey from an FTP site failed when the control
program was not able to change the directory to that of the user. Verify that the FTP site directory specified is correct and that any firewall authentications were completed, if necessary, before performing the update. Try the operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F901 | A query of the current boot side of the secondary
processor returned a null. Verify that the authentication passwords for the service processors are synchronized and that the TCP/IP addresses of the service processors are not in the HMC DHCP servers removed list. Use the Update Managed System Password field under the Server and Partition panels to reset the password if necessary. Use the restricted shell "mksysconn -o auto" command to reset the HMC DHCP servers removed list and reconnect the affected service processors. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F902 | A query of the next boot side of the secondary processor
returned a null. Verify that the authentication passwords for the service processors are synchronized and that the TCP/IP addresses of the service processors are not in the HMC DHCP servers removed list. Use the Update Managed System Password pulldown under the Server and Partition panels to reset the password if necessary. Use the restricted shell "mksysconn -o auto" command to reset the HMC DHCP servers removed list and reconnect the affected service processors. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F910 | An exception occurred when querying to find out
if the bulk power assembly was N-mode. Verify that both the primary and secondary service processors for the bulk power assembly (or assemblies) are configured properly and available for communication with the HMC. This is a requirement. Retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F911 | A failure occurred when querying to find out if
the bulk power assembly was N-mode. Verify that both the primary and secondary service processors for the bulk power assembly (or assemblies) are configured properly and available for communication with the HMC. This is a requirement. Retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F912 | One of the bulk power assemblies targeted for firmware
update has N-mode power. Verify that both the primary and secondary service processors for the bulk power assembly (or assemblies) are configured properly and available for communication with the HMC. This is a requirement. Retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F913 | One of the bulk power assemblies targeted for firmware
update has a power code update pending. A code update cannot be performed while a service processor in the bulk power assembly is running an auto-code download process. Depending on the number of FRUs being loaded, this process might take a significantly long time. After two hours, try the original operation again. If the failure occurs again, wait two hours and manually point the next re-IPL of the service processor to the "P" side by using the Flash Side Selection panels. Perform a "Disruptive Activate" using the Select advanced features panels. Wait two hours for that auto-code download to complete, and then try the original operation again. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F914 | An exception occurred when attempting to start the
power code update on a bulk power assembly. If another error occurs before this message, follow the action for that error. If this message occurs by itself, contact your next level of support. |
NEXTLVL |
| E302F915 | A failure occurred when attempting to start the
power code update on a bulk power assembly. If another error occurs before this message, follow the action for that error. If this message occurs by itself, contact your next level of support. |
NEXTLVL |
| E302F916 | An exception occurred when attempting to determine
how many FRUs were completed after an asynchronous event was received. If another error occurs before this message, follow the action for that error. If this message occurs by itself, contact your next level of support. |
NEXTLVL |
| E302F917 | A failure occurred when attempting to determine how many FRUs were
completed after an asynchronous event was received. If another error occurs before this message, follow the action for that error. If this message occurs by itself, contact your next level of support. |
NEXTLVL |
| E302F918 | The power code update failed on one side of the
BPA. If another error occurs before this message, follow the action for that error. If this message occurs by itself, contact your next level of support. |
NEXTLVL |
| E302F919 | The power code update began but did not complete
successfully. Perform an "Accept" operation followed by a "Disruptive Activate" using the Select advanced features panels. This sequence also accepts the system unit code. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F91A | An error occurred in the service processor support
code during a query of the state of a service processor for a frame. Reboot the HMC and retry the operation. If the error occurs again, contact your next level of support. |
NEXTLVL |
| E302F91B | A failure occurred when attempting to query the
state of the system unit after an receiving an asynchronous report that the
state had changed. Reboot the HMC and retry the operation. If the error occurs again, contact your next level of support. |
NEXTLVL |
| E302F91C | A failure occurred while copying the firmware from
the T side to the P side after a successful update of the bulk power controller
code. Perform an "Accept" operation using the Select advanced features panels. This operation also accepts the system unit code. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F91D | A failure occurred when trying to deactivate a bulk
power assembly. Reboot the HMC and retry the operation. If the error occurs again, contact your next level of support. |
NEXTLVL |
| E302F91F | An exception occurred when trying to deactivate
a bulk power assembly. Reboot the HMC and retry the operation. If the error occurs again, contact your next level of support. |
NEXTLVL |
| E302F9AF | An error occurred during the processing for the
advanced features task when trying to run a tasklet exit on the client to
display the license panel. The task is terminated. Reboot the HMC and retry the operation. If the error occurs again, contact your next level of support. |
NEXTLVL |
| E302F9B0 | An error occurred during the processing for the
MES upgrade task when trying to run a tasklet exit on the client to display
the license panel. The task is terminated. Reboot the HMC and retry the operation. If the error occurs again, contact your next level of support. |
NEXTLVL |
| E302F9B1 | An error occurred during the processing for the
change internal code wizard when trying to run a tasklet exit on the client
to display the license panel. The task is terminated. Reboot the HMC and retry the operation. If the error occurs again, contact your next level of support. |
NEXTLVL |
| E302F9B2 | Error during processing for the Change Internal Code Wizard Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9B3 | Error during processing for an internal code method. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9B4 to E302F9B6 | Error during processing for an internal panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9B7 | Error during processing of the server side of the scheduleable
update task. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9B8 | Error trying to perform processing in a hardware upgrade
code path. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9B9 | Error during the main "service" processing for the server
side of the hardware upgrade task. The task has been terminated. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9BA | Error during the main processing for the client side of
the hardware upgrade task. The task has been terminated. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9BB | Error during the main processing for the server side of
the hardware upgrade task. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9BC | Error during the processing of the actual non disruptive
firmware update task. The progress panel for the affected target is updated
with error message. The task continues to execute. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9BD | Error during the main "service" processing for the server
side of the change internal code wizard subtasklet. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9BE | Error during the main "service" processing for the server
side of the change internal code wizard1 panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9BF | Error during the main "service" processing for the server
side of the change internal code wizard2 panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9C0 | Error during the main "service" processing for the server
side of the change internal code wizard3 panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9C1 | Error during the main "service" processing for the server
side of the change internal code wizard4 panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9C2 | Error during the main "service" processing for the server
side of the change internal code wizard cecconcurrency panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9C3 | Error during the main "service" processing for the server
side of the change internal code wizard cecdetails panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9C4 | Error during the main "service" processing for the server
side of the change internal code wizard fix details panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9C5 | Error during the main "service" processing for the server
side of the change internal code wizard license panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9C6 | Error during the main "service" processing for the server
side of the change internal code wizard leveldetails panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9C7 | Error during the main processing for the server side of
the flash side selection task. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9C8 | Error during the main "service" processing for the server
side of the advanced features subtasklet. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9C9 | Error during processing for the advanced features panel
handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9CA | Error during processing for the advanced features retrieve
panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9CB | Error during processing for the advanced features implied
retrieve panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9CC | Error during processing for the advanced features change
levels panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9CD | Error during processing for the advanced features select
change levels panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9CE | Error during processing for the advanced features install
type panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9CF | Error during processing for the advanced features fix
details panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9D0 | Error during processing for the advanced features confirm
panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9D1 | Error during processing for the advanced features level
details panel handler. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9D2 | Error during the main "service" processing for the server
side of the change internal code task. The task is terminated. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9D3 | Error during processing change internal code MainPanel
panel handler. The task is terminated. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9D4 | Error during processing change internal code MainRepos
panel handler. The task is terminated. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9D5 | Error during processing change internal code InbandMessage
panel handler. The task is terminated. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9D6 | Error during processing change internal code FtpPanel
panel handler. The task is terminated. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9D7 | Error during processing change internal code ChangeFTP
panel handler. The task is terminated. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9D8 | Error trying to assign values from a SysInfoEcInternalCodeData
object. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9D9 | Error during the main processing for the server side of
the system information task. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9DA | Error from getting null presentation task parameters in
the system information task. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9DB | Error during the processing for the server side SysInfoEcTasklet
system information subtask. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9DC | Error trying to do the main processing for the client
side of the change internal code task. The task has been terminated. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9DD | Error trying to do the main processing for the client
side of the flash side selection task. The task has been terminated. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9DE | Error trying to do the main processing for the client
side of the non disruptive firmware update task. The task has been terminated. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9DF | Error during the main processing for the server side of
the advanced features subtask. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9E0 | Error during the main processing for the server side of
the advanced targeting subtask. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9E1 | Error during the main processing for the server side of
the Change Internal Code task. This could be the result of an exception being
caught by the underlying tasklet infrastructure. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9E2 | Error during the main processing for the server side of
the Nondisruptive Firmware Update task. This could be the result of an exception
being caught by the underlying tasklet infrastructure. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9E3 | Error during the main processing for the server side of
the Change Internal Code Wizard subtask. This could be the result of an exception
being caught by the underlying tasklet infrastructure. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9E4 | Error trying to perform some processing in the Advanced
Features Bean panelAction() method. The bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9E5 | Error trying to perform some processing in the Advanced
Targeting for Frames Bean panelAction() method. The bean attempts to close
the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9E6 | Error trying to perform some processing in the Advanced
Targeting for System Bean panelAction() method. The bean attempts to close
the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9E7 | Error in the select advanced targeting type bean panelAction
method. This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9E8 | Error in the CEC/power concurrency bean panelAction method.
This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9E9 | Error in the CEC/power level details bean panelAction
method. This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9EA | Error in the change FTP directory bean panelAction method.
This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9EB | Error in the specify levels bean panelAction method. This
bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9EC | Error in the advanced features confirm bean panelAction
method. This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9ED | Error in the LIC details bean panelAction method. This
bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9EE | Error in the flash side selection bean panelAction method.
This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9EF | Error in the FTP site access bean panelAction method.
This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9F0 | Error in the advanced features install and activate (implied
retrieval) bean panelAction method. This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9F1 | Error in the inband configuration detected bean panelAction
method. This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9F2 | Error in the advanced features select installation type
bean panelAction method. This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9F3 | Error in the confirmation level details bean panelAction
method. This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9F4 | Error in the license agreement bean panelAction method.
This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9F5 | Error in the change internal code main bean panelAction
method. This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9F6 | Error in the change internal code main repos bean panelAction
method. This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9F7 | Error in the nondisruptive firmware update bean panelAction
method. This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9F8 | Error in the advanced features retrieve bean panelAction
method. This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9F9 | Error in the select advanced targeting frame choice bean
panelAction method. This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9FA | Error in the advanced features select level bean panelAction
method. This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9FB | Error in the system information bean panelAction method.
This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9FC, E302F9FD | Error in the change internal code wizard1 bean panelAction
method. This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9FE | Error in the change internal code wizard2 bean panelAction
method. This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |
| E302F9FF | Error in the change internal code wizard3 bean panelAction
method. This bean attempts to close the panel. Reboot the HMC and retry the operation. If the problem occurs again, contact your next level of support. |
NEXTLVL |