SRNs 2512-101 through 25D0-108

Replace FRU parts in the order in which the failing function codes are listed. Go to the Failing function code list to access the failing function codes.

The SRNs listed are the only SRNs that should occur on the storage facility. If you have an SRN that is not listed below, the SRN is probably not valid for the storage facility. Contact your next level of support. You can also look up the SRN on the eServer Information Center website.

Service Request Number Failing Function Codes Description/Action
2593-101 2593 Unable to open device driver. Action: Use MAP0210 General problem resolution.
2593-201 25A0 Unable to configure adapter. Action: Use MAP0210 General problem resolution.
2593-202
2593
25A0
Media
Unable to configure the device. Action: Use MAP0210 General problem resolution.
2593-203 25A0 Unable to open device driver. Action: Use MAP0210 General problem resolution.
2593-204
Media
2593
The Inquire command failed. Action: Use MAP0210 General problem resolution.
2593-205
2593
Media
The Read Sense Data command failed. Action: Use MAP0210 General problem resolution.
2593-206 2593 The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution.
2593-207
Media
2593
A media error was detected. Action: Use MAP0210 General problem resolution.
2593-208
2593
Media
The DVD-ROM Play Audio command failed. Action: Use MAP0210 General problem resolution.
2593-209 2593 No tone during audio test. Action: Use MAP0210 General problem resolution.
2593-210 2593 The Prevent Media Removal or Allow Media Removal command failed. Action: Use MAP0210 General problem resolution.
2593-211 2593 DVD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution.
2593-212 2593 The Write/Read/Compare Test Failed. Action: Use MAP0210 General problem resolution.
2593-701 2593 ELA indicates drive hardware failure. Action: Use MAP0210 General problem resolution.
2593-702 2593 ELA indicates drive hardware failure. Action: Use MAP0210 General problem resolution.