SRNs 2600-101 through 2600-704

Replace FRU parts in the order by which the "Failing Function Codes" are listed. Go to Failing function code list to access the failing function codes.

Service Request Number Failing Function Codes Description/Action
2600-101 2600 The Fibre Channel Adapter configuration failed. Action: Go to MAP0210 General problem resolution.
2600-102 2600 The Reset test failed. Action: Go to MAP0210 General problem resolution.
2600-103 2600 The Register test failed. Action: Go to MAP0210 General problem resolution.
2600-104 2600 The SRAM test failed. Action: Go to MAP0210 General problem resolution.
2600-105 2600 The Internal Wrap test failed. Action: Go to MAP0210 General problem resolution.
2600-106 2600 The Gigabaud Link Module (GLM) Wrap Test Failure. Action: Go to MAP0210 General problem resolution.
2600-107 2600 The External Wrap test failed. Action: Go to MAP0210 General problem resolution.
2600-109 221 Enhanced Error Handling Failure on EADs chip. Action: Go to MAP0210 General problem resolution.
2600-110 2600 Enhanced Error Handling Failure on adapter. Action: Go to MAP0210 General problem resolution.
2600-201
2600
221
The Configuration Register test failed. Action: Go to MAP0210 General problem resolution.
2600-202
2600
221
The Interrupt test failed. Action: Go to MAP0210 General problem resolution.
2600-203
2600
221
The PCI Wrap test failed. Action: Go to MAP0210 General problem resolution.
2600-204
2600
221
The DMA test failed. Action: Go to MAP0210 General problem resolution.
2600-205
2600
221
I/O error on a read/write operation. Action: Go to MAP0210 General problem resolution.
2600-701
2600
221
Error log analysis indicates that an error has occurred with the adapter. Action: Go to MAP0210 General problem resolution.
2600-703 2600 Error log analysis indicates that an unknown adapter error has occurred. Action: Go to MAP0210 General problem resolution.
2600-704 2600 Error log analysis indicates that an adapter error has occurred. Action: Go to MAP0210 General problem resolution.
2600-705 2600 A parity error has been detected. The adapter must be replaced immediately. Failure to do so could result in data being read or written incorrectly. Action: Go to MAP0210 General problem resolution.
2600-706 2600 A fatal hardware error has occurred. This adapter was successfully taken offline. It will remain offline until reconfigured or the system is rebooted. This adapter must be replaced and not brought back online. Failure to adhere to this action could result in data being read or written incorrectly or in the loss of data.
2601-102 2601 The Reset test failed. Action: Go to MAP0210 General problem resolution.
2601-103 2601 The Register test failed. Action: Go to MAP0210 General problem resolution.
2601-104 2601 The SRAM test failed. Action: Go to MAP0210 General problem resolution.
2601-105 2601 The Internal Wrap test failed. Action: Go to MAP0210 General problem resolution.
2601-106 2601 The Gigabaud Link Module (GLM) Wrap Test Failure. Action: Go to MAP0210 General problem resolution.
2601-107 2601 The External Wrap test failed. Action: Go to MAP0210 General problem resolution.
2601-108 221 Enhanced Error Handling Failure on bus. Action: Go to MAP0210 General problem resolution.
2601-110 2601 Enhanced Error Handling Failure on adapter. Action: Go to MAP0210 General problem resolution.
2601-201
2601
221
The Configuration Register test failed. Action: Go to MAP0210 General problem resolution.
2601-202
2601
221
The Interrupt test failed. Action: Go to MAP0210 General problem resolution.
2601-203 2601 The PCI Wrap test failed. Action: Go to MAP0210 General problem resolution.
2601-204
2601
221
The DMA test failed. Action: Go to MAP0210 General problem resolution.
2601-205
2601
221
I/O error on a read/write operation. Action: Go to MAP0210 General problem resolution.
2601-701 2601 Error log analysis indicates that an error has occurred with the adapter. Action: Go to MAP0210 General problem resolution.
2601-703 2601 Error log analysis indicates that an unknown adapter error has occurred. Action: Go to MAP0210 General problem resolution.
2601-704 2601 Error log analysis indicates that an adapter error has occurred. Action: Go to MAP0210 General problem resolution.
2640-114 2640 IDE Disk diagnostic failure. Action: Go to MAP0210 General problem resolution.
2640-115
2640
2631
IDE disk error on open or configuring device. Action: Go to MAP0210 General problem resolution.
2640-121 2640 Physical volume hardware error. Action: Go to MAP0210 General problem resolution.
2640-131 2640 Smart status threshold exceeded. Action: Go to MAP0210 General problem resolution.
2640-132 2640 Command timeouts threshold exceeded. Action: Go to MAP0210 General problem resolution.
2640-133 2640 Command timeout with error condition. Action: Go to MAP0210 General problem resolution.
2640-134 2640 Hardware command or DMA failure. Action: Go to MAP0210 General problem resolution.
2640-135 2640 IDE DMA error with no error status. Action: Go to MAP0210 General problem resolution.
2640-136
2640
2631
TimeOut waiting for controller or drive with no busy status. Action: Go to MAP0210 General problem resolution.