SRNs A00-FF0 through A25-001
This section lists the SRNs A00-FF0 through A25-001
8 4 2 1
| | | |
| | | Replace all FRUs listed
| | Hot swap supported
| Software might be the cause
Reserved
Use the physical location codes and FRU numbers listed on the diagnostics Problem Report Screen. Failing Function Codes (FFCs) are not used in this group of SRNs. For more detailed information refer to MAP 0230: Platform error problem resolution.
| Service Request Number | Failing Function Codes | Description/Action |
|---|---|---|
| A00-FF0 | Description: Error log analysis is unable to determine
the error. The error log indicates the following physical FRU locations as
the probable causes. Action: Use MAP 0230: Platform error problem resolution. |
|
| A01-00x | Description: Error log analysis indicates an error detected
by the CPU, but the failure could not be isolated. Action: Use MAP 0230: Platform error problem resolution. |
|
| A01-01x | Description: CPU internal error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A01-02x | Description: CPU internal cache or cache controller
error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A01-03x | Description: External cache parity or multi-bit ECC
error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A01-04x | Description: External cache ECC single-bit error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A01-05x | Description: System bus time-out error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A01-06x | Description: Time-out error waiting for I/O. Action: Use MAP 0230: Platform error problem resolution. |
|
| A01-07x | Description: System bus parity error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A01-08x | Description: System bus protocol/transfer error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A02-00x | Description: Error log analysis indicates an error detected
by the memory controller, but the failure could not be isolated. Action: Use MAP 0230: Platform error problem resolution. |
|
| A02-01x | Description: Uncorrectable Memory Error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A02-02x | Description: ECC correctable error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A02-03x | Description: Correctable error threshold exceeded. Action: Use MAP 0230: Platform error problem resolution. |
|
| A02-04x | Description: Memory Control subsystem internal error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A02-05x | Description: Memory Address Error (invalid address or
access attempt). Action: Use MAP 0230: Platform error problem resolution. |
|
| A02-06x | Description: Memory Data error (Bad data going to memory). Action: Use MAP 0230: Platform error problem resolution. |
|
| A02-07x | Description: Memory bus/switch internal error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A02-08x | Description: Memory time-out error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A02-09x | Description: System bus parity error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A02-10x | Description: System bus time-out error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A02-11x | Description: System bus protocol/transfer error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A02-12x | Description: I/O Host Bridge time-out error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A02-13x | Description: I/O Host Bridge address/data parity error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A02-15x | Description: System support function error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A02-16x | Description: System bus internal hardware/switch error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A03-00x | Description: Error log analysis indicates an error detected
by the I/O device, but the failure could not be isolated. Action: Use MAP 0230: Platform error problem resolution. |
|
| A03-01x | Description: I/O Bus Address parity error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A03-02x | Description: I/O Bus Data parity error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A03-03x | Description: I/O bridge/device time-out, access or other
error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A03-04x | Description: I/O bridge/device internal error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A03-05x | Description: I/O Error on non-PCI bus. Action: Use MAP 0230: Platform error problem resolution. |
|
| A03-06x | Description: Mezzanine bus address parity error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A03-07x | Description: System bus address parity error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A03-08x | Description: Mezzanine bus data parity error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A03-09x | Description: System bus data parity error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A03-10x | Description: Mezzanine bus time-out, transfer or protocol
error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A03-11x | Description: System bus time-out error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A03-12x | Description: Error on System bus. Action: Use MAP 0230: Platform error problem resolution. |
|
| A03-13x | Description: I/O Expansion bus parity error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A03-14x | Description: I/O Expansion bus time-out error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A03-15x | Description: I/O Expansion bus connection failure. Action: Use MAP 0230: Platform error problem resolution. |
|
| A03-16x | Description: I/O Expansion unit not in an operating
state. Action: Use MAP 0230: Platform error problem resolution. |
|
| A05-00x | Description: Error log analysis indicates an environmental
and power warning, but the failure could not be isolated. Action: Use MAP 0230: Platform error problem resolution. |
|
| A05-01x | Description: Sensor indicates a fan has failed. Action: Use MAP 0230: Platform error problem resolution. |
|
| A05-02x | Description: System shutdown due to a fan failure. Action: Use MAP 0230: Platform error problem resolution. |
|
| A05-03x | Description: Sensor indicates a voltage outside normal
range. Action: Use Power problem isolation for your system. |
|
| A05-04x | Description: System shutdown due to voltage outside
normal range. Action: Use Power problem isolation for your system. |
|
| A05-05x | Description: Sensor indicates an abnormally high internal
temperature. Action: Verify that:
If none of these problems exist, then proceed with MAP 0230: Platform error problem resolution. |
|
| A05-06x | Description: System shutdown due to abnormally high
internal temperature. Action: Verify that:
If none of these problems exist, then proceed with MAP 0230: Platform error problem resolution. |
|
| A05-07x | Description: Sensor indicates a power supply has failed. Action: Use MAP 0230: Platform error problem resolution. |
|
| A05-08x | Description: System shutdown due to power supply failure. Action: Use MAP 0230: Platform error problem resolution. |
|
| A05-09x | Description: Sensor detected a FRU that has failed. Action: Use MAP 0230: Platform error problem resolution. |
|
| A05-10x | Description: System shutdown due to FRU that has failed. Action: Use MAP 0230: Platform error problem resolution. |
|
| A05-14x | Description: System shutdown due to power fault with
an unspecified cause. Action: Use MAP 0230: Platform error problem resolution. |
|
| A05-16x | Description: System shutdown due to internal power supply
failure. Action: Use MAP 0230: Platform error problem resolution. |
|
| A05-19x | Description: System shutdown due to Fan failure. Action: Use MAP 0230: Platform error problem resolution. |
|
| A05-21x | Description: System shutdown due to over temperature
condition. Action: Verify the following:
If all conditions are met, then use MAP 0230: Platform error problem resolution. |
|
| A05-22x | Description: System shutdown due to over temperature
and fan failure. Action: Use MAP 0230: Platform error problem resolution. |
|
| A05-24x | Description: Power fault specifically due to internal
battery failure. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-00x | Description: Error log analysis indicates an error detected
by the service processor, but the failure could not be isolated. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-01x | Note: Ensure that the system IPLROS and service processor
are at the latest firmware level before removing any parts from the system.
Description:
Time-out communication response from service processor. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-02x | Description: I/O (I2C) general bus error. Note: If you
are servicing a 9076/Nxx system, go to the service processor Error Log (SVP).
Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-03x | Description: Secondary I/O (I2C) general bus error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-04x | Description: Internal service processor memory error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-05x | Description: Service processor error accessing special
registers. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-06x | Description: Service processor reports unknown communication
error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-07x | Description: Internal service processor firmware error
or incorrect version. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-08x | Description: Other internal service processor hardware
error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-09x | Description: Service processor error accessing vital
product data EEPROM. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-10x | Description: Service processor error accessing operator
panel. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-11x | Description: Service processor error accessing power
controller. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-12x | Description: Service processor error accessing fan sensor. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-13x | Description: Service processor error accessing thermal
sensor. Note: If you are servicing a 9076/Nxx system, go to the service processor
Error Log (SVP).
Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-14x | Description: Service processor error accessing voltage
sensor. Note: If you are servicing a 9076/Nxx system, go to the service processor
Error Log (SVP).
Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-17x | Description: Service processor error accessing serial
port. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-18x | Description: Service processor detected NVRAM error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-19x | Description: Service processor error accessing real
time clock/time-of-day clock. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-20x | Description: Service processor error accessing scan
controller/hardware. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-21x | Description: Service processor detected error with time-of-day
clock backup battery. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-23x | Description: Loss of heart beat from service processor. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-24x | Description: Service processor detected a surveillance
time-out. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-25x | Description: Power control network general connection
failure. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-26x | Description: Power control network node failure. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-29x | Description: Service processor error accessing power
control network. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-30x | Description: Non-supported hardware. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-31x | Description: Error detected while handling an attention/interrupt
from the system hardware. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-33x | Description: Array of Logic Built in Self Test Error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-34x | Description: Wire Test Error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-35x | Description: Mainstore or Cache IPL Diagnostic Error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-36x | Description: Other IPL Diagnostic Error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-37x | Description: Clock or PLL Error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-38x | Description: Hardware Scan or Initialization Error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-39x | Description: Chip ID Verification Error. Action: Use MAP 0230: Platform error problem resolution. |
|
| A0D-40x | Description: FRU Presence/Detect Error (Mis-Plugged). Action: Use MAP 0230: Platform error problem resolution. |
|
| A10-100 | Description: The resource is unavailable due to an error.
System is operating in degraded mode. Action: Use MAP 0230: Platform error problem resolution. |
|
| A10-200 | Description: The resource was marked failed by the platform.
The system is operating in degraded mode. Action: Use MAP 0230: Platform error problem resolution. |
|
| A10-210 | Description: The processor has been deconfigured. The
system is operating in degraded mode. Action: Use MAP 0230: Platform error problem resolution. |
|
| A11-00x | Description: A non-critical error has been detected.
Error log analysis indicates an error detected by the CPU, but the failure
could not be isolated. Action: Use MAP 0230: Platform error problem resolution. |
|
| A11-01x | Description: A non-critical error has been detected,
a CPU internal error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A11-02x | Description: A non-critical error has been detected,
a CPU internal cache or cache controller error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A11-03x | Description: A non-critical error has been detected,
an external cache parity or multi-bit ECC error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A11-04x | Description: A non-critical error has been detected,
an external cache ECC single-bit error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A11-05x | Description: A non-critical error has been detected,
a system bus time-out error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A11-06x | Description: A non-critical error has been detected,
a time-out error waiting for an I/O device. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A11-07x | Description: A non-critical error has been detected,
a system bus parity error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A11-08x | Description: A non-critical error has been detected,
a system bus protocol/transfer error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A11-50x | Description: Recoverable errors on resource indicate
a trend toward an unrecoverable error. However, the resource could not be
deconfigured and is still in use. The system is operating with the potential
for an unrecoverable error. Action: If repair is not immediately available, reboot and the resource will be deconfigured. Then operations can continue in a degraded mode. To repair use MAP 0230: Platform error problem resolution. |
|
| A11-510 | Description: Resource has been deconfigured and is no
longer in use due to a trend toward an unrecoverable error. Action: The system is operating in a degraded mode. Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A11-520 | Description: Recoverable errors on resource indicate
a trend toward an unrecoverable error. However, the resource could not be
deconfigured and is still in use. The system is operating with the potential
for an unrecoverable error. Action: Try removing the processes from the failing processor and retry the deconfiguration; use the ha_star -C command. An alternative is reboot, and the processor will be deconfigured. Then the system can continue in a degraded mode. To repair use MAP 0230: Platform error problem resolution. |
|
| A11-530 | Description: Recoverable errors on resource indicate
a trend toward an unrecoverable error. However, the resource could not be
deconfigured and is still in use. The system is operating with the potential
for an unrecoverable error. Run-time processor deconfiguration can be enabled
to deconfigure the processor. Action: To enable run-time processor deconfiguration, use the chdev -a cpuguard=enable -l sys0 command. Then to retry the deconfiguration, use the ha_star -C command. An alternative is reboot, and the processor will be deconfigured. Then the system can continue in a degraded mode. To repair use MAP 0230: Platform error problem resolution. |
|
| A11-540 | Description: Recoverable errors on resource indicate
a trend toward an unrecoverable error. However, the resource could not be
deconfigured and is still in use. The system is operating with the potential
for an unrecoverable error. Action: If repair is not immediately available, reboot and the resource will be deconfigured. Then operations can continue in a degraded mode. To repair use MAP 0230: Platform error problem resolution. |
|
| A11-550 | Description: Recoverable errors on resource indicate
a trend toward an unrecoverable error. However, the resource could not be
deconfigured and is still in use. The system is operating with the potential
for an unrecoverable error. Action: If repair is not immediately available, reboot and the resource will be deconfigured. Then operations can continue in a degraded mode. To repair use MAP 0230: Platform error problem resolution. |
|
| A11-560 | Description: Recoverable errors on a resource indicate
a potential for unrecoverable errors. The resource cannot be deconfigured
and is still in use. The problem may be corrected by array bit steering. Action: Use MAP 0235: System array self-repair problem resolution. |
|
| A11-570 | Description: A processor has been deconfigured due to
a trend toward an unrecoverable error. The system is operating in a degraded
mode. The problem may be corrected by array bit steering. Action: Use MAP 0235: System array self-repair problem resolution. |
|
| A11-580 | Description: Recoverable errors on a processor indicate
a potential for an unrecoverable error. The resource cannot be deconfigured
and is still in use. The problem may be corrected by array bit steering. Action: Use MAP 0235: System array self-repair problem resolution. |
|
| A12-00x | Description: A non-critical error has been detected.
Error log analysis indicates an error detected by the memory controller, but
the failure could not be isolated. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A12-01x | Description: A non-critical error has been detected,
an uncorrectable memory error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A12-02x | Description: A non-critical error has been detected,
an ECC correctable error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A12-03x | Description: A non-critical error has been detected,
a correctable error threshold exceeded. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A12-04x | Description: A non-critical error has been detected,
a memory control subsystem internal error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A12-05x | Description: A non-critical error has been detected,
a memory address error (invalid address or access attempt). Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A12-06x | Description: A non-critical error has been detected,
a memory data error (bad data going to memory). Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A12-07x | Description: A non-critical error has been detected,
a memory bus/switch internal error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A12-08x | Description: A non-critical error has been detected,
a memory time-out error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A12-09x | Description: A non-critical error has been detected,
a system bus parity error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A12-10x | Description: A non-critical error has been detected,
a system bus time-out error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A12-11x | Description: A non-critical error has been detected,
a system bus protocol/transfer error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A12-12x | Description: A non-critical error has been detected,
an I/O host bridge time-out error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A12-13x | Description: A non-critical error has been detected,
a I/O host bridge address/data parity error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A12-15x | Description: A non-critical error has been detected,
a system support function error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A12-16x | Description: A non-critical error has been detected,
a system bus internal hardware/switch error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A12-50x | Description: Recoverable errors on resource indicate
a trend toward an unrecoverable error. However, the resource could not be
deconfigured and is still in use. The system is operating with the potential
for an unrecoverable error. Action: If repair is not immediately available, reboot and the resource will be deconfigured. Then operations can continue in a degraded mode. Use MAP 0230: Platform error problem resolution. |
|
| A13-00x | Description: A non-critical error has been detected,
a error log analysis indicates an error detected by the I/O device, but the
failure could not be isolated. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A13-01x | Description: A non-critical error has been detected,
an I/O bus address parity error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A13-02x | Description: A non-critical error has been detected,
an I/O bus data parity error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A13-03x | Description: A non-critical error has been detected,
an I/O bus time-out, access or other error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A13-04x | Description: A non-critical error has been detected,
an I/O bridge/device internal error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A13-05x | Description: A non-critical error has been detected,
an I/O error on non-PCI bus. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A13-06x | Description: A non-critical error has been detected,
a mezzanine bus address parity error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A13-07x | Description: A non-critical error has been detected,
a system bus address parity error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A13-08x | Description: A non-critical error has been detected,
a mezzanine bus data parity error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A13-09x | Description: A non-critical error has been detected,
a system bus data parity error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A13-10x | Description: A non-critical error has been detected,
a mezzanine bus time-out error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A13-11x | Description: A non-critical error has been detected,
a system bus time-out error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A13-12x | Description: A non-critical error has been detected,
an error on system bus. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A13-13x | Description: A non-critical error has been detected,
an I/O expansion bus parity error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A13-14x | Description: A non-critical error has been detected,
an I/O expansion bus time-out error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A13-15x | Description: A non-critical error has been detected,
an I/O expansion bus connection failure. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A13-16x | Description: A non-critical error has been detected,
an I/O expansion unit not in an operating state. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A13-50x | Description: Recoverable errors on resource indicate
a trend toward an unrecoverable error. However, the resource could not be
deconfigured and is still in use. The system is operating with the potential
for an unrecoverable error. Action: If repair is not immediately available, reboot and the resource will be deconfigured. Then operations can continue in a degraded mode. To repair use MAP 0230: Platform error problem resolution. |
|
| A15-01x | Description: Sensor indicates a fan is turning too slowly. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A15-03x | Description: Sensor indicates a voltage outside normal
range. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A15-05x | Description: Sensor indicates an abnormally high internal
temperature. Action: Verify that:
If none of these problems exist, then proceed with MAP 0230: Platform error problem resolution. |
|
| A15-07x | Description: Sensor indicates a power supply has failed. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A15-09x | Description: Sensor indicates a FRU has failed. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A15-11x | Description: Sensor detected a redundant fan failure. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A15-12x | Description: Sensor detected redundant power supply
failure. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A15-13x | Description: Sensor detected a redundant FRU that has
failed. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A15-14x | Description: Power fault due to unspecified cause. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A15-16x | Description: Internal power supply failure. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A15-17x | Description: Internal redundant power supply failure. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A15-19x | Description: Fan failure. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A15-20x | Description: Non-critical cooling problem, loss of redundant
fan. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A15-21x | Description: Over temperature condition. Action:
Verify the following:
If all conditions are met, then use MAP 0230: Platform error problem resolution. |
|
| A15-22x | Description: Fan failure and Over temperature condition. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A15-23x | Description: Non-critical power problem, loss of redundant
power supply. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A15-24x | Description: Power Fault specifically due to internal
battery failure. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A15-50x | Description: Recoverable errors on resource indicate
a trend toward an unrecoverable error. However, the resource could not be
deconfigured and is still in use. The system is operating with the potential
for an unrecoverable error. Action: If repair is not immediately available, reboot and the resource will be deconfigured. Then operations can continue in a degraded mode. To repair use MAP 0230: Platform error problem resolution. |
|
| A1D-00x | Description: A non-critical error has been detected.
Error log analysis indicates an error detected by the service processor, but
the failure could not be isolated. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-01x | Note: Ensure that the system IPLROS and service processor
are at the latest firmware level before removing any parts from the system.
Description:
A non-critical error has been detected. Time Out communication response from
service processor.Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-02x | Description: A non-critical error has been detected,
an I/O (I2C) general bus error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-03x | Description: A non-critical error has been detected,
a secondary I/O (I2C) general bus error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-04x | Description: A non-critical error has been detected,
an internal service processor memory error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-05x | Description: A non-critical error has been detected,
a service processor error accessing special registers. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-06x | Description: A non-critical error has been detected,
a service processor reports unknown communication error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-07x | Description: A non-critical error has been detected.
Internal service processor firmware error or incorrect version. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-08x | Description: A non-critical error has been detected,
an other internal service processor hardware error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-09x | Description: A non-critical error has been detected,
a service processor error accessing vital product data EEPROM. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-10x | Description: A non-critical error has been detected,
a service processor error accessing operator panel. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-11x | Description: A non-critical error has been detected,
a service processor error accessing power controller. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-12x | Description: A non-critical error has been detected,
a service processor error accessing fan sensor. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-13x | Description: A non-critical error has been detected,
a service processor error accessing a thermal sensor. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-14x | Description: A non-critical error has been detected,
a service processor error accessing voltage sensor. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-17x | Description: A non-critical error has been detected,
a service processor error accessing serial port. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-18x | Description: A non-critical error has been detected,
a service processor detected NVRAM error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-19x | Description: A non-critical error has been detected,
a service processor error accessing real time clock/time-of-day clock. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-20x | Description: A non-critical error has been detected:
Service processor error accessing scan controller/hardware. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-21x | Description: A non-critical error has been detected,
a service processor detected error with time-of-day clock backup battery. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-23x | Description: A non-critical error has been detected:
Loss of heart beat from service processor. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-24x | Description: A non-critical error has been detected,
a service processor detected a surveillance time-out. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-25x | Description: A non-critical error has been detected,
a power control network general connection failure. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-26x | Description: A non-critical error has been detected,
a power control network node failure. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-29x | Description: A non-critical error has been detected,
a service process error accessing power control network. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-30x | Description: A non-critical error has been detected:
Non-supported hardware. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-31x | Description: A non-critical error has been detected:
Error detected while handling an attention/interrupt from the system hardware. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-33x | Description: A non-critical error has been detected:
Array of Logic Built in Self Test Error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-34x | Description: A non-critical error has been detected:
Wire Test Error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-35x | Description: A non-critical error has been detected:
Mainstore or Cache IPL Diagnostic Error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-36x | Description: A non-critical error has been detected:
Other IPL Diagnostic Error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-37x | Description: A non-critical error has been detected:
Clock or PLL Error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-38x | Description: A non-critical error has been detected:
Hardware Scan or Initialization Error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-39x | Description: A non-critical error has been detected:
Chip ID Verification Error. Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-40x | Description: A non-critical error has been detected:
Presence/Detect Error (Mis-Plugged). Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution. |
|
| A1D-50x | Description: Recoverable errors on resource indicate
a trend toward an unrecoverable error. However, the resource could not be
deconfigured and is still in use. The system is operating with the potential
for an unrecoverable error. Action: If repair is not immediately available, reboot and the resource will be deconfigured. Then operations can continue in a degraded mode. To repair use MAP 0230: Platform error problem resolution. |
|
| A22-xxxx | xxxx | Defective Multipath I/O Device. Note: To obtain the FFC, substitute the last 3
or 4 digits after the dash (-) for xxxx (The substituted xxxx is the
FFC).
Action: Use MAP0210 General problem resolution. |
| A23-001 | Multipath I/O Problem Resolution. Action: Use MAP 0285: Multipath I/O (MPIO) problem resolution. |
|
| A24-000 | Use part number from diagnostics 227 | Spurious interrupts on shared interrupt level have exceeded threshold.
Action: Use the part numbers reported by diagnostics and use MAP0210 General problem resolution. |
| A24-xxx | Use xxx 227 | Spurious interrupts have exceeded threshold. Action: Use MAP0210 General problem resolution. |
| A25-001 | Platform error, switch network interface extended error
data is available. Action: Refer to the hardware management console. Use the system reference codes in the serviceable event view for this partition. |