SRNs A00-FF0 through A25-001

This section lists the SRNs A00-FF0 through A25-001

The x in the following group of SRNs is encoded as follows:
  8  4  2  1
  |  |  |  |
  |  |  |  Replace all FRUs listed
  |  |  Hot swap supported
  |  Software might be the cause
  Reserved
Note: Some SRNs in this chapter may have 4 rather than 3 digits after the dash (-).

Use the physical location codes and FRU numbers listed on the diagnostics Problem Report Screen. Failing Function Codes (FFCs) are not used in this group of SRNs. For more detailed information refer to MAP 0230: Platform error problem resolution.

Service Request Number Failing Function Codes Description/Action
A00-FF0   Description: Error log analysis is unable to determine the error. The error log indicates the following physical FRU locations as the probable causes.

Action: Use MAP 0230: Platform error problem resolution.

A01-00x   Description: Error log analysis indicates an error detected by the CPU, but the failure could not be isolated.

Action: Use MAP 0230: Platform error problem resolution.

A01-01x   Description: CPU internal error.

Action: Use MAP 0230: Platform error problem resolution.

A01-02x   Description: CPU internal cache or cache controller error.

Action: Use MAP 0230: Platform error problem resolution.

A01-03x   Description: External cache parity or multi-bit ECC error.

Action: Use MAP 0230: Platform error problem resolution.

A01-04x   Description: External cache ECC single-bit error.

Action: Use MAP 0230: Platform error problem resolution.

A01-05x   Description: System bus time-out error.

Action: Use MAP 0230: Platform error problem resolution.

A01-06x   Description: Time-out error waiting for I/O.

Action: Use MAP 0230: Platform error problem resolution.

A01-07x   Description: System bus parity error.

Action: Use MAP 0230: Platform error problem resolution.

A01-08x   Description: System bus protocol/transfer error.

Action: Use MAP 0230: Platform error problem resolution.

A02-00x   Description: Error log analysis indicates an error detected by the memory controller, but the failure could not be isolated.

Action: Use MAP 0230: Platform error problem resolution.

A02-01x   Description: Uncorrectable Memory Error.

Action: Use MAP 0230: Platform error problem resolution.

A02-02x   Description: ECC correctable error.

Action: Use MAP 0230: Platform error problem resolution.

A02-03x   Description: Correctable error threshold exceeded.

Action: Use MAP 0230: Platform error problem resolution.

A02-04x   Description: Memory Control subsystem internal error.

Action: Use MAP 0230: Platform error problem resolution.

A02-05x   Description: Memory Address Error (invalid address or access attempt).

Action: Use MAP 0230: Platform error problem resolution.

A02-06x   Description: Memory Data error (Bad data going to memory).

Action: Use MAP 0230: Platform error problem resolution.

A02-07x   Description: Memory bus/switch internal error.

Action: Use MAP 0230: Platform error problem resolution.

A02-08x   Description: Memory time-out error.

Action: Use MAP 0230: Platform error problem resolution.

A02-09x   Description: System bus parity error.

Action: Use MAP 0230: Platform error problem resolution.

A02-10x   Description: System bus time-out error.

Action: Use MAP 0230: Platform error problem resolution.

A02-11x   Description: System bus protocol/transfer error.

Action: Use MAP 0230: Platform error problem resolution.

A02-12x   Description: I/O Host Bridge time-out error.

Action: Use MAP 0230: Platform error problem resolution.

A02-13x   Description: I/O Host Bridge address/data parity error.

Action: Use MAP 0230: Platform error problem resolution.

A02-15x   Description: System support function error.

Action: Use MAP 0230: Platform error problem resolution.

A02-16x   Description: System bus internal hardware/switch error.

Action: Use MAP 0230: Platform error problem resolution.

A03-00x   Description: Error log analysis indicates an error detected by the I/O device, but the failure could not be isolated.

Action: Use MAP 0230: Platform error problem resolution.

A03-01x   Description: I/O Bus Address parity error.

Action: Use MAP 0230: Platform error problem resolution.

A03-02x   Description: I/O Bus Data parity error.

Action: Use MAP 0230: Platform error problem resolution.

A03-03x   Description: I/O bridge/device time-out, access or other error.

Action: Use MAP 0230: Platform error problem resolution.

A03-04x   Description: I/O bridge/device internal error.

Action: Use MAP 0230: Platform error problem resolution.

A03-05x   Description: I/O Error on non-PCI bus.

Action: Use MAP 0230: Platform error problem resolution.

A03-06x   Description: Mezzanine bus address parity error.

Action: Use MAP 0230: Platform error problem resolution.

A03-07x   Description: System bus address parity error.

Action: Use MAP 0230: Platform error problem resolution.

A03-08x   Description: Mezzanine bus data parity error.

Action: Use MAP 0230: Platform error problem resolution.

A03-09x   Description: System bus data parity error.

Action: Use MAP 0230: Platform error problem resolution.

A03-10x   Description: Mezzanine bus time-out, transfer or protocol error.

Action: Use MAP 0230: Platform error problem resolution.

A03-11x   Description: System bus time-out error.

Action: Use MAP 0230: Platform error problem resolution.

A03-12x   Description: Error on System bus.

Action: Use MAP 0230: Platform error problem resolution.

A03-13x   Description: I/O Expansion bus parity error.

Action: Use MAP 0230: Platform error problem resolution.

A03-14x   Description: I/O Expansion bus time-out error.

Action: Use MAP 0230: Platform error problem resolution.

A03-15x   Description: I/O Expansion bus connection failure.

Action: Use MAP 0230: Platform error problem resolution.

A03-16x   Description: I/O Expansion unit not in an operating state.

Action: Use MAP 0230: Platform error problem resolution.

A05-00x   Description: Error log analysis indicates an environmental and power warning, but the failure could not be isolated.

Action: Use MAP 0230: Platform error problem resolution.

A05-01x   Description: Sensor indicates a fan has failed.

Action: Use MAP 0230: Platform error problem resolution.

A05-02x   Description: System shutdown due to a fan failure.

Action: Use MAP 0230: Platform error problem resolution.

A05-03x   Description: Sensor indicates a voltage outside normal range.

Action: Use Power problem isolation for your system.

A05-04x   Description: System shutdown due to voltage outside normal range.

Action: Use Power problem isolation for your system.

A05-05x   Description: Sensor indicates an abnormally high internal temperature.
Action: Verify that:
  1. The room ambient temperature is within the system operating environment.
  2. There is unrestricted air flow around the system.
  3. All system covers are closed.
  4. There are no fan failures.

If none of these problems exist, then proceed with MAP 0230: Platform error problem resolution.

A05-06x   Description: System shutdown due to abnormally high internal temperature.
Action: Verify that:
  1. The room ambient temperature is within the system operating environment.
  2. There is unrestricted air flow around the system.
  3. All system covers are closed.
  4. There are no fan failures.

If none of these problems exist, then proceed with MAP 0230: Platform error problem resolution.

A05-07x   Description: Sensor indicates a power supply has failed.

Action: Use MAP 0230: Platform error problem resolution.

A05-08x   Description: System shutdown due to power supply failure.

Action: Use MAP 0230: Platform error problem resolution.

A05-09x   Description: Sensor detected a FRU that has failed.

Action: Use MAP 0230: Platform error problem resolution.

A05-10x   Description: System shutdown due to FRU that has failed.

Action: Use MAP 0230: Platform error problem resolution.

A05-14x   Description: System shutdown due to power fault with an unspecified cause.

Action: Use MAP 0230: Platform error problem resolution.

A05-16x   Description: System shutdown due to internal power supply failure.

Action: Use MAP 0230: Platform error problem resolution.

A05-19x   Description: System shutdown due to Fan failure.

Action: Use MAP 0230: Platform error problem resolution.

A05-21x   Description: System shutdown due to over temperature condition.
Action: Verify the following:
  1. The room ambient temperature is within the system operating environment.
  2. There is unrestricted air flow around the system.
  3. All system covers are closed.

If all conditions are met, then use MAP 0230: Platform error problem resolution.

A05-22x   Description: System shutdown due to over temperature and fan failure.

Action: Use MAP 0230: Platform error problem resolution.

A05-24x   Description: Power fault specifically due to internal battery failure.

Action: Use MAP 0230: Platform error problem resolution.

A0D-00x   Description: Error log analysis indicates an error detected by the service processor, but the failure could not be isolated.

Action: Use MAP 0230: Platform error problem resolution.

A0D-01x  
Note: Ensure that the system IPLROS and service processor are at the latest firmware level before removing any parts from the system.
Description: Time-out communication response from service processor.

Action: Use MAP 0230: Platform error problem resolution.

A0D-02x   Description: I/O (I2C) general bus error.
Note: If you are servicing a 9076/Nxx system, go to the service processor Error Log (SVP).

Action: Use MAP 0230: Platform error problem resolution.

A0D-03x   Description: Secondary I/O (I2C) general bus error.

Action: Use MAP 0230: Platform error problem resolution.

A0D-04x   Description: Internal service processor memory error.

Action: Use MAP 0230: Platform error problem resolution.

A0D-05x   Description: Service processor error accessing special registers.

Action: Use MAP 0230: Platform error problem resolution.

A0D-06x   Description: Service processor reports unknown communication error.

Action: Use MAP 0230: Platform error problem resolution.

A0D-07x   Description: Internal service processor firmware error or incorrect version.

Action: Use MAP 0230: Platform error problem resolution.

A0D-08x   Description: Other internal service processor hardware error.

Action: Use MAP 0230: Platform error problem resolution.

A0D-09x   Description: Service processor error accessing vital product data EEPROM.

Action: Use MAP 0230: Platform error problem resolution.

A0D-10x   Description: Service processor error accessing operator panel.

Action: Use MAP 0230: Platform error problem resolution.

A0D-11x   Description: Service processor error accessing power controller.

Action: Use MAP 0230: Platform error problem resolution.

A0D-12x   Description: Service processor error accessing fan sensor.

Action: Use MAP 0230: Platform error problem resolution.

A0D-13x   Description: Service processor error accessing thermal sensor.
Note: If you are servicing a 9076/Nxx system, go to the service processor Error Log (SVP).

Action: Use MAP 0230: Platform error problem resolution.

A0D-14x   Description: Service processor error accessing voltage sensor.
Note: If you are servicing a 9076/Nxx system, go to the service processor Error Log (SVP).

Action: Use MAP 0230: Platform error problem resolution.

A0D-17x   Description: Service processor error accessing serial port.

Action: Use MAP 0230: Platform error problem resolution.

A0D-18x   Description: Service processor detected NVRAM error.

Action: Use MAP 0230: Platform error problem resolution.

A0D-19x   Description: Service processor error accessing real time clock/time-of-day clock.

Action: Use MAP 0230: Platform error problem resolution.

A0D-20x   Description: Service processor error accessing scan controller/hardware.

Action: Use MAP 0230: Platform error problem resolution.

A0D-21x   Description: Service processor detected error with time-of-day clock backup battery.

Action: Use MAP 0230: Platform error problem resolution.

A0D-23x   Description: Loss of heart beat from service processor.

Action: Use MAP 0230: Platform error problem resolution.

A0D-24x   Description: Service processor detected a surveillance time-out.

Action: Use MAP 0230: Platform error problem resolution.

A0D-25x   Description: Power control network general connection failure.

Action: Use MAP 0230: Platform error problem resolution.

A0D-26x   Description: Power control network node failure.

Action: Use MAP 0230: Platform error problem resolution.

A0D-29x   Description: Service processor error accessing power control network.

Action: Use MAP 0230: Platform error problem resolution.

A0D-30x   Description: Non-supported hardware.

Action: Use MAP 0230: Platform error problem resolution.

A0D-31x   Description: Error detected while handling an attention/interrupt from the system hardware.

Action: Use MAP 0230: Platform error problem resolution.

A0D-33x   Description: Array of Logic Built in Self Test Error.

Action: Use MAP 0230: Platform error problem resolution.

A0D-34x   Description: Wire Test Error.

Action: Use MAP 0230: Platform error problem resolution.

A0D-35x   Description: Mainstore or Cache IPL Diagnostic Error.

Action: Use MAP 0230: Platform error problem resolution.

A0D-36x   Description: Other IPL Diagnostic Error.

Action: Use MAP 0230: Platform error problem resolution.

A0D-37x   Description: Clock or PLL Error.

Action: Use MAP 0230: Platform error problem resolution.

A0D-38x   Description: Hardware Scan or Initialization Error.

Action: Use MAP 0230: Platform error problem resolution.

A0D-39x   Description: Chip ID Verification Error.

Action: Use MAP 0230: Platform error problem resolution.

A0D-40x   Description: FRU Presence/Detect Error (Mis-Plugged).

Action: Use MAP 0230: Platform error problem resolution.

A10-100   Description: The resource is unavailable due to an error. System is operating in degraded mode.

Action: Use MAP 0230: Platform error problem resolution.

A10-200   Description: The resource was marked failed by the platform. The system is operating in degraded mode.

Action: Use MAP 0230: Platform error problem resolution.

A10-210   Description: The processor has been deconfigured. The system is operating in degraded mode.

Action: Use MAP 0230: Platform error problem resolution.

A11-00x   Description: A non-critical error has been detected. Error log analysis indicates an error detected by the CPU, but the failure could not be isolated.

Action: Use MAP 0230: Platform error problem resolution.

A11-01x   Description: A non-critical error has been detected, a CPU internal error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A11-02x   Description: A non-critical error has been detected, a CPU internal cache or cache controller error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A11-03x   Description: A non-critical error has been detected, an external cache parity or multi-bit ECC error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A11-04x   Description: A non-critical error has been detected, an external cache ECC single-bit error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A11-05x   Description: A non-critical error has been detected, a system bus time-out error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A11-06x   Description: A non-critical error has been detected, a time-out error waiting for an I/O device.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A11-07x   Description: A non-critical error has been detected, a system bus parity error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A11-08x   Description: A non-critical error has been detected, a system bus protocol/transfer error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A11-50x   Description: Recoverable errors on resource indicate a trend toward an unrecoverable error. However, the resource could not be deconfigured and is still in use. The system is operating with the potential for an unrecoverable error.

Action: If repair is not immediately available, reboot and the resource will be deconfigured. Then operations can continue in a degraded mode. To repair use MAP 0230: Platform error problem resolution.

A11-510   Description: Resource has been deconfigured and is no longer in use due to a trend toward an unrecoverable error.

Action: The system is operating in a degraded mode. Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A11-520   Description: Recoverable errors on resource indicate a trend toward an unrecoverable error. However, the resource could not be deconfigured and is still in use. The system is operating with the potential for an unrecoverable error.

Action: Try removing the processes from the failing processor and retry the deconfiguration; use the ha_star -C command. An alternative is reboot, and the processor will be deconfigured. Then the system can continue in a degraded mode. To repair use MAP 0230: Platform error problem resolution.

A11-530   Description: Recoverable errors on resource indicate a trend toward an unrecoverable error. However, the resource could not be deconfigured and is still in use. The system is operating with the potential for an unrecoverable error. Run-time processor deconfiguration can be enabled to deconfigure the processor.

Action: To enable run-time processor deconfiguration, use the chdev -a cpuguard=enable -l sys0 command. Then to retry the deconfiguration, use the ha_star -C command. An alternative is reboot, and the processor will be deconfigured. Then the system can continue in a degraded mode. To repair use MAP 0230: Platform error problem resolution.

A11-540   Description: Recoverable errors on resource indicate a trend toward an unrecoverable error. However, the resource could not be deconfigured and is still in use. The system is operating with the potential for an unrecoverable error.

Action: If repair is not immediately available, reboot and the resource will be deconfigured. Then operations can continue in a degraded mode. To repair use MAP 0230: Platform error problem resolution.

A11-550   Description: Recoverable errors on resource indicate a trend toward an unrecoverable error. However, the resource could not be deconfigured and is still in use. The system is operating with the potential for an unrecoverable error.

Action: If repair is not immediately available, reboot and the resource will be deconfigured. Then operations can continue in a degraded mode. To repair use MAP 0230: Platform error problem resolution.

A11-560   Description: Recoverable errors on a resource indicate a potential for unrecoverable errors. The resource cannot be deconfigured and is still in use. The problem may be corrected by array bit steering.

Action: Use MAP 0235: System array self-repair problem resolution.

A11-570   Description: A processor has been deconfigured due to a trend toward an unrecoverable error. The system is operating in a degraded mode. The problem may be corrected by array bit steering.

Action: Use MAP 0235: System array self-repair problem resolution.

A11-580   Description: Recoverable errors on a processor indicate a potential for an unrecoverable error. The resource cannot be deconfigured and is still in use. The problem may be corrected by array bit steering.

Action: Use MAP 0235: System array self-repair problem resolution.

A12-00x   Description: A non-critical error has been detected. Error log analysis indicates an error detected by the memory controller, but the failure could not be isolated.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A12-01x   Description: A non-critical error has been detected, an uncorrectable memory error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A12-02x   Description: A non-critical error has been detected, an ECC correctable error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A12-03x   Description: A non-critical error has been detected, a correctable error threshold exceeded.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A12-04x   Description: A non-critical error has been detected, a memory control subsystem internal error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A12-05x   Description: A non-critical error has been detected, a memory address error (invalid address or access attempt).

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A12-06x   Description: A non-critical error has been detected, a memory data error (bad data going to memory).

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A12-07x   Description: A non-critical error has been detected, a memory bus/switch internal error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A12-08x   Description: A non-critical error has been detected, a memory time-out error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A12-09x   Description: A non-critical error has been detected, a system bus parity error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A12-10x   Description: A non-critical error has been detected, a system bus time-out error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A12-11x   Description: A non-critical error has been detected, a system bus protocol/transfer error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A12-12x   Description: A non-critical error has been detected, an I/O host bridge time-out error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A12-13x   Description: A non-critical error has been detected, a I/O host bridge address/data parity error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A12-15x   Description: A non-critical error has been detected, a system support function error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A12-16x   Description: A non-critical error has been detected, a system bus internal hardware/switch error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A12-50x   Description: Recoverable errors on resource indicate a trend toward an unrecoverable error. However, the resource could not be deconfigured and is still in use. The system is operating with the potential for an unrecoverable error.

Action: If repair is not immediately available, reboot and the resource will be deconfigured. Then operations can continue in a degraded mode. Use MAP 0230: Platform error problem resolution.

A13-00x   Description: A non-critical error has been detected, a error log analysis indicates an error detected by the I/O device, but the failure could not be isolated.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A13-01x   Description: A non-critical error has been detected, an I/O bus address parity error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A13-02x   Description: A non-critical error has been detected, an I/O bus data parity error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A13-03x   Description: A non-critical error has been detected, an I/O bus time-out, access or other error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A13-04x   Description: A non-critical error has been detected, an I/O bridge/device internal error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A13-05x   Description: A non-critical error has been detected, an I/O error on non-PCI bus.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A13-06x   Description: A non-critical error has been detected, a mezzanine bus address parity error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A13-07x   Description: A non-critical error has been detected, a system bus address parity error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A13-08x   Description: A non-critical error has been detected, a mezzanine bus data parity error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A13-09x   Description: A non-critical error has been detected, a system bus data parity error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A13-10x   Description: A non-critical error has been detected, a mezzanine bus time-out error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A13-11x   Description: A non-critical error has been detected, a system bus time-out error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A13-12x   Description: A non-critical error has been detected, an error on system bus.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A13-13x   Description: A non-critical error has been detected, an I/O expansion bus parity error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A13-14x   Description: A non-critical error has been detected, an I/O expansion bus time-out error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A13-15x   Description: A non-critical error has been detected, an I/O expansion bus connection failure.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A13-16x   Description: A non-critical error has been detected, an I/O expansion unit not in an operating state.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A13-50x   Description: Recoverable errors on resource indicate a trend toward an unrecoverable error. However, the resource could not be deconfigured and is still in use. The system is operating with the potential for an unrecoverable error.

Action: If repair is not immediately available, reboot and the resource will be deconfigured. Then operations can continue in a degraded mode. To repair use MAP 0230: Platform error problem resolution.

A15-01x   Description: Sensor indicates a fan is turning too slowly.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A15-03x   Description: Sensor indicates a voltage outside normal range.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A15-05x   Description: Sensor indicates an abnormally high internal temperature.
Action: Verify that:
  1. The room ambient temperature is within the system operating environment.
  2. There is unrestricted air flow around the system.
  3. All system covers are closed.
  4. There are no fan failures.

If none of these problems exist, then proceed with MAP 0230: Platform error problem resolution.

A15-07x   Description: Sensor indicates a power supply has failed.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A15-09x   Description: Sensor indicates a FRU has failed.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A15-11x   Description: Sensor detected a redundant fan failure.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A15-12x   Description: Sensor detected redundant power supply failure.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A15-13x   Description: Sensor detected a redundant FRU that has failed.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A15-14x   Description: Power fault due to unspecified cause.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A15-16x   Description: Internal power supply failure.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A15-17x   Description: Internal redundant power supply failure.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A15-19x   Description: Fan failure.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A15-20x   Description: Non-critical cooling problem, loss of redundant fan.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A15-21x   Description: Over temperature condition.
Action: Verify the following:
  • The room ambient temperature is within the system operating environment.
  • There is unrestricted air flow around the system.
  • All system covers are closed.

If all conditions are met, then use MAP 0230: Platform error problem resolution.

A15-22x   Description: Fan failure and Over temperature condition.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A15-23x   Description: Non-critical power problem, loss of redundant power supply.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A15-24x   Description: Power Fault specifically due to internal battery failure.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A15-50x   Description: Recoverable errors on resource indicate a trend toward an unrecoverable error. However, the resource could not be deconfigured and is still in use. The system is operating with the potential for an unrecoverable error.

Action: If repair is not immediately available, reboot and the resource will be deconfigured. Then operations can continue in a degraded mode. To repair use MAP 0230: Platform error problem resolution.

A1D-00x   Description: A non-critical error has been detected. Error log analysis indicates an error detected by the service processor, but the failure could not be isolated.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-01x  
Note: Ensure that the system IPLROS and service processor are at the latest firmware level before removing any parts from the system.
Description: A non-critical error has been detected. Time Out communication response from service processor.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-02x   Description: A non-critical error has been detected, an I/O (I2C) general bus error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-03x   Description: A non-critical error has been detected, a secondary I/O (I2C) general bus error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-04x   Description: A non-critical error has been detected, an internal service processor memory error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-05x   Description: A non-critical error has been detected, a service processor error accessing special registers.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-06x   Description: A non-critical error has been detected, a service processor reports unknown communication error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-07x   Description: A non-critical error has been detected. Internal service processor firmware error or incorrect version.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-08x   Description: A non-critical error has been detected, an other internal service processor hardware error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-09x   Description: A non-critical error has been detected, a service processor error accessing vital product data EEPROM.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-10x   Description: A non-critical error has been detected, a service processor error accessing operator panel.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-11x   Description: A non-critical error has been detected, a service processor error accessing power controller.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-12x   Description: A non-critical error has been detected, a service processor error accessing fan sensor.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-13x   Description: A non-critical error has been detected, a service processor error accessing a thermal sensor.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-14x   Description: A non-critical error has been detected, a service processor error accessing voltage sensor.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-17x   Description: A non-critical error has been detected, a service processor error accessing serial port.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-18x   Description: A non-critical error has been detected, a service processor detected NVRAM error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-19x   Description: A non-critical error has been detected, a service processor error accessing real time clock/time-of-day clock.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-20x   Description: A non-critical error has been detected: Service processor error accessing scan controller/hardware.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-21x   Description: A non-critical error has been detected, a service processor detected error with time-of-day clock backup battery.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-23x   Description: A non-critical error has been detected: Loss of heart beat from service processor.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-24x   Description: A non-critical error has been detected, a service processor detected a surveillance time-out.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-25x   Description: A non-critical error has been detected, a power control network general connection failure.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-26x   Description: A non-critical error has been detected, a power control network node failure.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-29x   Description: A non-critical error has been detected, a service process error accessing power control network.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-30x   Description: A non-critical error has been detected: Non-supported hardware.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-31x   Description: A non-critical error has been detected: Error detected while handling an attention/interrupt from the system hardware.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-33x   Description: A non-critical error has been detected: Array of Logic Built in Self Test Error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-34x   Description: A non-critical error has been detected: Wire Test Error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-35x   Description: A non-critical error has been detected: Mainstore or Cache IPL Diagnostic Error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-36x   Description: A non-critical error has been detected: Other IPL Diagnostic Error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-37x   Description: A non-critical error has been detected: Clock or PLL Error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-38x   Description: A non-critical error has been detected: Hardware Scan or Initialization Error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-39x   Description: A non-critical error has been detected: Chip ID Verification Error.

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-40x   Description: A non-critical error has been detected: Presence/Detect Error (Mis-Plugged).

Action: Schedule deferred maintenance. Use MAP 0230: Platform error problem resolution.

A1D-50x   Description: Recoverable errors on resource indicate a trend toward an unrecoverable error. However, the resource could not be deconfigured and is still in use. The system is operating with the potential for an unrecoverable error.

Action: If repair is not immediately available, reboot and the resource will be deconfigured. Then operations can continue in a degraded mode. To repair use MAP 0230: Platform error problem resolution.

A22-xxxx xxxx Defective Multipath I/O Device.
Note: To obtain the FFC, substitute the last 3 or 4 digits after the dash (-) for xxxx (The substituted xxxx is the FFC).
Action: Use MAP0210 General problem resolution.
A23-001   Multipath I/O Problem Resolution.

Action: Use MAP 0285: Multipath I/O (MPIO) problem resolution.

A24-000 Use part number from diagnostics 227 Spurious interrupts on shared interrupt level have exceeded threshold.

Action: Use the part numbers reported by diagnostics and use MAP0210 General problem resolution.

A24-xxx Use xxx 227 Spurious interrupts have exceeded threshold.

Action: Use MAP0210 General problem resolution.

A25-001   Platform error, switch network interface extended error data is available.