Testing management console communications
Procedure
-
Test the service communication methods.
Table 1. Tests for management console communications Communication method How to test Call Home - From the navigation area, click Storage Facility Management.
- From the right work area, select the appropriate storage facility. The bottom Task area displays a list of tasks you can select.
- From the bottom Task area, click Service Utilities > Test Problem Notification (PMH, SNMP, Email). The Test Problem Notification (PMH, SNMP, Email) window opens and lists the storage facility and its expansion racks, if any.
- Perform the test on each of the listed racks:
- Select the first rack in the list and click Test Callhome.
- When you are prompted to generate a serviceable event with reference code BEB20010, click Yes.
- When the message TestPMR Successful is displayed, make note of the rack serial number and problem ID, then click OK.
- Repeat the test for the remaining racks.
- Check open SRC BEB20010s and confirm a PMH number has been returned from RETAIN. This return may take a while.
Note: You have previously verified that this storage facility is registered in Retain earlier in this installation. If the test fails, go to MAP1301 Isolating Call Home/remote services failure. -
Test the customer communication methods.
Table 2. Test customer communication methods Communication method How to test Customer e-mail notification Select Service Management > Connectivity > Manage Serviceable Event Notification > Email tab > Test Email. Ask the customer if the e-mail was received. Note: If the test fails, go to MAP1310 Isolating e-mail notification problems.Customer connection to DS8000® Storage Manager server in the management console Ask the customer to test the access of the application or method that they will use to connect to the DS8000 Storage Manager in the management console. Note: If the test fails, go to MAP1301 Isolating Call Home/remote services failure. -
Send the first call home heartbeat.
- From the navigation area, click HMC Management.
- In the right work area, go to the Storage Server HMC Tasks section and click View/Change Heartbeat Configuration.
- Ensure the Send Heartbeat field is set to 7 days.
- Click Send Heartbeat Now.
- The Send an Instant Heartbeat window opens, click Yes.
- The Heartbeat status window displays for less than one minute.
- When the Successful window displays, follow the directions to ensure the heartbeat was sent then click OK to exit.
Note: The management console heartbeat function verifies that the HMC continues to be available for call home and remote service. The service representative sets the frequency (1, 7, 14, or 28 days) selected by the customer. The recommended setting is 7 days. The heartbeat function uses the HMC to create a serviceable event (SE) with SRC BEF00012. The SE contains the frequency setting, and is sent to IBM® with the normal SE call home function. The SE will automatically close after the heartbeat call-home completes successfully. If IBM does not receive these SEs at the recommended frequency, a service action to determine the cause can be initiated by next level of support. -
Repeat steps 1 through 3 for the secondary management console (MC
2).
Note: When finished configuring the secondary management console (MC 2), reconnect the keyboard and monitor to the primary management console (MC 1) ports.
- Go to the next section.