11001530 11001530
Explanation
Detected AC loss.
Response
Before replacing any parts, verify that the AC input voltage is
correct. Follow the instructions for the items listed in the FRU List.
Problem determination
The system might have experienced an AC Power Loss
external to the system such as utility or building power and the system might have recovered.
- If there was a utility, building or room power loss that would have affected the system at the
same time this SRC was reported then you can ignore and close this event. No service is required.
Otherwise continue with the next step in this procedure.
- Ensure the line cords are properly connected and seated on both ends. For help in locating the
line cords of the power supply reporting thi s problem use the location code in the serviceable
event or the symbolic FRU in the failing items list below.
- If the system was just installed or moved, verify the AC input voltage is correct.
- If the problem is not resolved then report this problem to your service provider.