B2001230 B2001230
Explanation
A problem occurred during the IPL of a partition.Response
The partition ID is in extended word one as LP=xxx in decimal format. This is a partitioning configuration problem. The partition is lacking the necessary resources to IPL. This error might occur when you shut down a partition that is set to automatically IPL and then turn the managed system off and back on. When the partition automatically IPLs, it uses the resources specified in PHYP NVRAM, and this error occurs when the server does not find the exact resources specified in NVRAM. The solution is to activate the partition by using the partition profile on the HMC. The HMC applies the values in the profile to NVRAM. When the partition IPLs, it uses the resources specified in the profile.Problem determination
No action is required.