B700F104 B700F104

Explanation

Operating System error

Response

Platform Licensed Internal Code terminated a partition. If SRC word 3 is 0018, then a user may have initiated a function 22 prior to the operating system completing the IPL. If a function 22 was not performed, or if SRC word 3 is not 0018, look for other serviceable errors which occurred at same time frame. If SRC word 3 is 0007 or 0009, then the failing partition received a Machine Check without having a Machine Check handler enabled. This could be due to the Machine Check occurring while the partition was in an IPL. If an IPL was not in progress, or word 3 is different, look for other serviceable errors which occurred at approximately the same time, and contact your next level of support.

Problem determination

No action is required.

Failing Item