FC-AL and Flash PCIe / SAS cables – Models 984, 84E

These tables show the point-to-point connections for FC-AL and Flash PCIe / SAS cables on a Model 984, with or without expansion racks.
Note:
  • Racks are shown with the maximum number of storage enclosures and device adapter cards. Your rack might contain fewer storage enclosures or device adapter cards.
  • The figures that follow show the maximum number of racks in a storage facility with these rack models.
Figure 1. Point-to-point cabling diagram for storage enclosure FC-AL and Flash PCIe / SAS cables (Models 984, 84E, rear view, racks 1, 2)
Point-to-point cabling diagram for storage enclosure FC-AL and Flash PCIe / SAS cables (Models 984, 84E, rear view, racks 1, 2)
Figure 2. Point-to-point cabling diagram for the FC-AL cables (Models 984, 84E, rack 3)
Point-to-point cabling diagram for the FC-AL cables (Models 984, 84E, rack 3)

FC-AL cables

  1. FC-AL cables and connectors are identified with two different color codes and a location designator:
    1. A colored band, corresponding to the color code of the DA pair, is found on each end of the cable near the connector. These color codes are shown in Figure 1 and Figure 2.
    2. The connector itself is color coded to help prevent cross-cabling at the Fibre Channel interface card (FCIC) or device adapter card (DA) end. The connectors always appear in the following order:
      beige (T1), green (T2), black (T3), and blue (T4)	
      as shown in Figure 3 and Figure 4. This color code is specific to each FCIC or DA, and is independent of the DA pair color code.
    3. A black or white label at each end of the cable shows a location designator (for example, 0A2). Both ends of the cable have the same location designator and DA pair color code. However, the connector at each end of the same cable usually does NOT have the same color code.
  2. Location designators are in the form CTP, where:
    C
    Is the device adapter pair (0-7)
    T
    Is the port pair on the device adapter (A, B, C, D, a, b, c, d) (uppercase for left device adapter in pair, lowercase for right device adapter in pair).
    P
    Is the logical position of the downstream FCIC in the loop.
    Example: 2a1 is the link between device adapter R1-XI4-P1-C6-T1 and R1-G07-P1-C1-T2.
    2
    Device adapter pair 2
    a
    First port pair on right adapter of device adapter pair (lowercase a)
    1
    First FCIC on loop of this port pair
    The connector plugged into R1-XI4-P1-C6-T1 (2a1) is beige, while the connector plugged into R1-G07-P1-C1-T2 (2a1) is green.
  3. Some connectors are for cables that would go to an optional expansion rack. In that case, only one instance of that designator is on the rack.
  4. The black and white label at each end may have a physical location code in addition to the location designator.
Figure 3. FC-AL cable connector color codes - Fibre Channel interface card (FCIC) end
FC-AL cable connector color codes - Fibre Channel interface card (FCIC) end
Figure 4. Flash PCIe cable connector color codes - I/O enclosure PCIe and PCN card end (-C7-T5 / -C7-T6)
FC-AL cable connector color codes - device adapter card (DA) end

FC-AL cabling tables

Table 1 and Table 2 show a summary of FC-AL cabling for models 984 and 84E (single-phase power).
Table 3 and Table 4 show details of the FC-AL loops originating with Rack 1 device adapters (device adapter pairs 2 and 3, in normal installation order).
Table 5 and Table 6 show details of the FC-AL loops originating with Rack 2 device adapters (device adapter pair 6 and 7, in normal installation order).
Note: Location designators are labeled as link in the following tables.
Table 1. FC-AL cabling summary – Rack 1 device adapters (Models 984, 84E)
From
DA Pair
DA
Pair (link)
To
Storage Enclosure
To
Storage Enclosure
To
Storage Enclosure
To
Storage Enclosure
R1-XI3-P1-C3-T1/T2
R1-XI4-P1-C6-T1/T2
2 (A)
2 (a)
R1-G07 R1-G05 R1-G03 R1-G01
R1-XI3-P1-C3-T3/T4
R1-XI4-P1-C6-T3/T4
2 (B)
2 (b)
R1-G08 R1-G06 R1-G04 R1-G02
R1-XI3-P1-C6-T1/T2
R1-XI4-P1-C3-T1/T2
3 (A)
3 (a)
R2-G09 R2-G07 R2-G05 R2-G03
R1-XI3-P1-C6-T3/T4
R1-XI4-P1-C3-T3/T4
3 (B)
3 (b)
R2-G10 R2-G08 R2-G06 R2-G04
Table 2. FC-AL cabling summary – Rack 2 device adapters (Models 984, 84E)
From
DA Pair
DA
Pair (link)
To
Storage Enclosure
To
Storage Enclosure
To
Storage Enclosure
To
Storage Enclosure
R2-XI3-P1-C3-T1/T2
R2-XI4-P1-C6-T1/T2
6 (A)
6 (a)
R2-G01 R3-G15 R3-G13 R3-G11
R2-XI3-P1-C3-T3/T4
R2-XI4-P1-C6-T3/T4
6 (B)
6 (b)
R2-G02 R3-G16 R3-G14 R3-G12
R2-XI3-P1-C6-T1/T2
R2-XI4-P1-C3-T1/T2
7 (A)
7 (a)
R3-G09 R3-G07 R3-G05 R3-G03
R2-XI3-P1-C6-T3/T4
R2-XI4-P1-C3-T3/T4
7 (B)
7 (b)
R3-G10 R3-G08 R3-G06 R3-G04
Table 3. FC-AL cabling matrix – DA Pair 2 (Models 984, 84E)
From
DA
link To
FCIC
From
FCIC
link To
FCIC
R1-XI3-P1-C3-T1 2A1 R1-G07-P1-C1-T1 R1-G07-P1-C1-T3 2A3 R1-G05-P1-C1-T1
R1-XI4-P1-C6-T1 2a1 R1-G07-P1-C1-T2 R1-G07-P1-C1-T4 2a3 R1-G05-P1-C1-T2
R1-XI3-P1-C3-T2 2A2 R1-G07-P1-C2-T1 R1-G07-P1-C2-T3 2A4 R1-G05-P1-C2-T1
R1-XI4-P1-C6-T2 2a2 R1-G07-P1-C2-T2 R1-G07-P1-C2-T4 2a4 R1-G05-P1-C2-T2
R1-XI3-P1-C3-T3 2B1 R1-G08-P1-C1-T1 R1-G08-P1-C1-T3 2B3 R1-G06-P1-C1-T1
R1-XI4-P1-C6-T3 2b1 R1-G08-P1-C1-T2 R1-G08-P1-C1-T4 2b3 R1-G06-P1-C1-T2
R1-XI3-P1-C3-T4 2B2 R1-G08-P1-C2-T1 R1-G08-P1-C2-T3 2B4 R1-G06-P1-C2-T1
R1-XI4-P1-C6-T4 2b2 R1-G08-P1-C2-T2 R1-G08-P1-C2-T4 2b4 R1-G06-P1-C2-T2
From
FCIC
link To
FCIC
From
FCIC
To
FCIC
R1-G05-P1-C1-T3 2A5 R1-G03-P1-C1-T1 R1-G03-P1-C1-T3 2A7 R1-G01-P1-C1-T1
R1-G05-P1-C1-T4 2a5 R1-G03-P1-C1-T2 R1-G03-P1-C1-T4 2a7 R1-G01-P1-C1-T2
R1-G05-P1-C2-T3 2A6 R1-G03-P1-C2-T1 R1-G03-P1-C2-T3 2A8 R1-G01-P1-C2-T1
R1-G05-P1-C2-T4 2a6 R1-G03-P1-C2-T2 R1-G03-P1-C2-T4 2a8 R1-G01-P1-C2-T2
R1-G06-P1-C1-T3 2B5 R1-G04-P1-C1-T1 R1-G04-P1-C1-T3 2B7 R1-G02-P1-C1-T1
R1-G06-P1-C1-T4 2b5 R1-G04-P1-C1-T2 R1-G04-P1-C1-T4 2b7 R1-G02-P1-C1-T2
R1-G06-P1-C2-T3 2B6 R1-G04-P1-C2-T1 R1-G04-P1-C2-T3 2B8 R1-G02-P1-C2-T1
R1-G06-P1-C2-T4 2b6 R1-G04-P1-C2-T2 R1-G04-P1-C2-T4 2b8 R1-G02-P1-C2-T2
Table 4. FC-AL cabling matrix – DA Pair 3 (Models 984, 84E)
From
DA
link To
FCIC
From
FCIC
To
FCIC
R1-XI3-P1-C6-T1 3A1 R2-G09-P1-C1-T1 R2-G09-P1-C1-T3 3A3 R2-G07-P1-C1-T1
R1-XI4-P1-C3-T1 3a1 R2-G09-P1-C1-T2 R2-G09-P1-C1-T4 3a3 R2-G07-P1-C1-T2
R1-XI3-P1-C6-T2 3A2 R2-G09-P1-C2-T1 R2-G09-P1-C2-T3 3A4 R2-G07-P1-C2-T1
R1-XI4-P1-C3-T2 3a2 R2-G09-P1-C2-T2 R2-G09-P1-C2-T4 3a4 R2-G07-P1-C2-T2
R1-XI3-P1-C6-T3 3B1 R2-G10-P1-C1-T1 R2-G10-P1-C1-T3 3B3 R2-G08-P1-C1-T1
R1-XI4-P1-C3-T3 3b1 R2-G10-P1-C1-T2 R2-G10-P1-C1-T4 3b3 R2-G08-P1-C1-T2
R1-XI3-P1-C6-T4 3B2 R2-G10-P1-C2-T1 R2-G10-P1-C2-T3 3B4 R2-G08-P1-C2-T1
R1-XI4-P1-C3-T4 3b2 R2-G10-P1-C2-T2 R2-G10-P1-C2-T4 3b4 R2-G08-P1-C2-T2
From
FCIC
link To
FCIC
From
FCIC
To
FCIC
R2-G07-P1-C1-T3 3A5 R2-G05-P1-C1-T1 R2-G05-P1-C1-T3 3A7 R2-G03-P1-C1-T1
R2-G07-P1-C1-T4 3a5 R2-G05-P1-C1-T2 R2-G05-P1-C1-T4 3a7 R2-G03-P1-C1-T2
R2-G07-P1-C2-T3 3A6 R2-G05-P1-C2-T1 R2-G05-P1-C2-T3 3A8 R2-G03-P1-C2-T1
R2-G07-P1-C2-T4 3a6 R2-G05-P1-C2-T2 R2-G05-P1-C2-T4 3a8 R2-G03-P1-C2-T2
R2-G08-P1-C1-T3 3B5 R2-G06-P1-C1-T1 R2-G06-P1-C1-T3 3B7 R2-G04-P1-C1-T1
R2-G08-P1-C1-T4 3b5 R2-G06-P1-C1-T2 R2-G06-P1-C1-T4 3b7 R2-G04-P1-C1-T2
R2-G08-P1-C2-T3 3B6 R2-G06-P1-C2-T1 R2-G06-P1-C2-T3 3B8 R2-G04-P1-C2-T1
R2-G08-P1-C2-T4 3b6 R2-G06-P1-C2-T2 R2-G06-P1-C2-T4 3b8 R2-G04-P1-C2-T2
Table 5. FC-AL cabling matrix – DA Pair 6 (Models 984, 84E)
From
DA
link To
FCIC
From
FCIC
link To
FCIC
R2-XI3-P1-C3-T1 6A1 R2-G01-P1-C1-T1 R2-G01-P1-C1-T3 6A3 R3-G15-P1-C1-T1
R2-XI4-P1-C6-T1 6a1 R2-G01-P1-C1-T2 R2-G01-P1-C1-T4 6a3 R3-G15-P1-C1-T2
R2-XI3-P1-C3-T2 6A2 R2-G01-P1-C2-T1 R2-G01-P1-C2-T3 6A4 R3-G15-P1-C2-T1
R2-XI4-P1-C6-T2 6a2 R2-G01-P1-C2-T2 R2-G01-P1-C2-T4 6a4 R3-G15-P1-C2-T2
R2-XI3-P1-C3-T3 6B1 R2-G02-P1-C1-T1 R2-G02-P1-C1-T3 6B3 R3-G16-P1-C1-T1
R2-XI4-P1-C6-T3 6b1 R2-G02-P1-C1-T2 R2-G02-P1-C1-T4 6b3 R3-G16-P1-C1-T2
R2-XI3-P1-C3-T4 6B2 R2-G02-P1-C2-T1 R2-G02-P1-C2-T3 6B4 R3-G16-P1-C2-T1
R2-XI4-P1-C6-T4 6b2 R2-G02-P1-C2-T2 R2-G02-P1-C2-T4 6b4 R3-G16-P1-C2-T2
From
FCIC
link To
FCIC
From
FCIC
link To
FCIC
R3-G15-P1-C1-T3 6A5 R3-G13-P1-C1-T1 R3-G13-P1-C1-T3 6A7 R3-G11-P1-C1-T1
R3-G15-P1-C1-T4 6a5 R3-G13-P1-C1-T2 R3-G13-P1-C1-T4 6a7 R3-G11-P1-C1-T2
R3-G15-P1-C2-T3 6A6 R3-G13-P1-C2-T1 R3-G13-P1-C2-T3 6A8 R3-G11-P1-C2-T1
R3-G15-P1-C2-T4 6a6 R3-G13-P1-C2-T2 R3-G13-P1-C2-T4 6a8 R3-G11-P1-C2-T2
R3-G16-P1-C1-T3 6B5 R3-G14-P1-C1-T1 R3-G14-P1-C1-T3 6B7 R3-G12-P1-C1-T1
R3-G16-P1-C1-T4 6b5 R3-G14-P1-C1-T2 R3-G14-P1-C1-T4 6b7 R3-G12-P1-C1-T2
R3-G16-P1-C2-T3 6B6 R3-G14-P1-C2-T1 R3-G14-P1-C2-T3 6B8 R3-G12-P1-C2-T1
R3-G16-P1-C2-T4 6b6 R3-G14-P1-C2-T2 R3-G14-P1-C2-T4 6b8 R3-G12-P1-C2-T2
Table 6. FC-AL cabling matrix – DA Pair 7 (Models 984, 84E)
From
DA
link To
FCIC
From
FCIC
link To
FCIC
R2-XI3-P1-C6-T1 7A1 R3-G09-P1-C1-T1 R3-G09-P1-C1-T3 7A3 R3-G07-P1-C1-T1
R2-XI4-P1-C3-T1 7a1 R3-G09-P1-C1-T2 R3-G09-P1-C1-T4 7a3 R3-G07-P1-C1-T2
R2-XI3-P1-C6-T2 7A2 R3-G09-P1-C2-T1 R3-G09-P1-C2-T3 7A4 R3-G07-P1-C2-T1
R2-XI4-P1-C3-T2 7a2 R3-G09-P1-C2-T2 R3-G09-P1-C2-T4 7a4 R3-G07-P1-C2-T2
R2-XI3-P1-C6-T3 7B1 R3-G10-P1-C1-T1 R3-G10-P1-C1-T3 7B3 R3-G08-P1-C1-T1
R2-XI4-P1-C3-T3 7b1 R3-G10-P1-C1-T2 R3-G10-P1-C1-T4 7b3 R3-G08-P1-C1-T2
R2-XI3-P1-C6-T4 7B2 R3-G10-P1-C2-T1 R3-G10-P1-C2-T3 7B4 R3-G08-P1-C2-T1
R2-XI4-P1-C3-T4 7b2 R3-G10-P1-C2-T2 R3-G10-P1-C2-T4 7b4 R3-G08-P1-C2-T2
From
FCIC
link To
FCIC
From
FCIC
link To
FCIC
R3-G07-P1-C1-T3 7A5 R3-G05-P1-C1-T1 R3-G05-P1-C1-T3 7A7 R3-G03-P1-C1-T1
R3-G07-P1-C1-T4 7a5 R3-G05-P1-C1-T2 R3-G05-P1-C1-T4 7a7 R3-G03-P1-C1-T2
R3-G07-P1-C2-T3 7A6 R3-G05-P1-C2-T1 R3-G05-P1-C2-T3 7A8 R3-G03-P1-C2-T1
R3-G07-P1-C2-T4 7a6 R3-G05-P1-C2-T2 R3-G05-P1-C2-T4 7a8 R3-G03-P1-C2-T2
R3-G08-P1-C1-T3 7B5 R3-G06-P1-C1-T1 R3-G06-P1-C1-T3 7B7 R3-G04-P1-C1-T1
R3-G08-P1-C1-T4 7b5 R3-G06-P1-C1-T2 R3-G06-P1-C1-T4 7b7 R3-G04-P1-C1-T2
R3-G08-P1-C2-T3 7B6 R3-G06-P1-C2-T1 R3-G06-P1-C2-T3 7B8 R3-G04-P1-C2-T1
R3-G08-P1-C2-T4 7b6 R3-G06-P1-C2-T2 R3-G06-P1-C2-T4 7b8 R3-G04-P1-C2-T2

Flash PCIe cables

  1. Flash PCIe cables and connectors are identified with a colored band matching the DA pair and two different color codes:
    • A colored band, corresponding to the color code of the DA pair, is found on each end of the cable near the connector. These color codes are shown in Figure 1.
    • The connector is color-coded to help prevent cross-cabling at the microbay adapter card or I/O enclosure PCIe and PCN card end. Connectors on cables attaching to Rx-Mxx-C1-T7 have white labels with black text, and connectors on cables attaching to Rx-Mxx-C2-T7 have black labels with white text. An example of this showing both cables attaching to a microbay adapter card pair is shown in Figure 5. This alternating color scheme is the same for all Flash PCIe cables, and is independent of the DA pair color code. Figure 6 and Figure 7 show the Flash PCIe cable connection ends.
  2. The black and white label at each end has a physical location code showing the "FROM" and "TO" end.
Figure 5. Flash PCIe cable connector example. Both cables are shown and actual values might not match this machine model.
Flash PCIe cable connector example; both cables are shown and actual values might not match this machine model.
Figure 6. Flash PCIe cable connector - microbay adapter card end (C1-T7 / C2-T7)
Flash PCIe cable connector - Microbay adapter card end (C1-T7 / C2-T7)
Figure 7. Flash PCIe cable connector - I/O enclosure PCIe and PCN card end (-C7-T5 / -C7-T6)
I/O enclosure locations (rear) (models 98x)

Flash SAS cables

  1. SAS cables and connectors are identified with two different color codes and a location designator:
    1. A colored band, corresponding to the color code of the DA pair, is found on each end of the cable near the connector. These color codes are shown in Figure 1.
    2. The connector itself is color coded to help prevent cross-cabling at the SAS expander card or device adapter card (DA) end. The connectors always appear in the following order:
      white (T1), green (T2), black (T3), and blue (T4)
      as shown in Figure 9 and Figure 10. This color code is specific to each SAS expander card or DA, and is independent of the DA pair color code.
    3. A black or white label at each end of the cable shows a location designator (for example, 16A1). Both ends of the cable have the same location designator and DA pair color code. However, the connector at each end of the same cable usually does NOT have the same color code.
    4. The following alternating color scheme is the same for all Flash SAS cables, and is independent of the DA pair color code:
      • Connectors on cables that attach to Rx-Mxx-C1-Tx have white labels with black text
      • Connectors on cables that attach to Rx-Mxx-C2-Tx have black labels with white text
      • Connectors on cables that attach to Rx-Mxx-C1-Tx have white labels with black text
      • Connectors on cables that attach to Rx-Mxx-C2-Tx have black labels with white text

    An example of this showing both ends of two SAS cables to an enclosure is shown in Figure 8.

  2. Location designators are in the form CTP, where:
    C
    Is the device adapter pair (16-23).
    T
    Is the port pair on the device adapter (A, B, a, b) (uppercase for left device adapter in pair, lowercase for right device adapter in pair).
    P
    Is the logical position of the downstream SAS expander card.
    Example: 16a1 is the link between device adapter R1-M02-C2-T1 and R1-F01-P1-C1-T2.
    16
    Device adapter pair 16
    a
    First port pair on right adapter of device adapter pair (lowercase a)
    1
    First SAS expander card
    The colored connector band plugged into R1-M02-C2-T1 (16a1) is white, while the colored connector band plugged into R1-F01-P1-C1-T2 (16a1) is green.
  3. The black and white label at each end may have a physical location code in addition to the location designator.
Figure 8. Flash SAS cable connector example. Two cables shown. Actual values might not match this machine model.
Flash SAS cable connector example. Two cables shown; actual values might not match this machine model.
Figure 9. Flash SAS cable connector color codes - SAS expander card end
Flash SAS cable connector color codes - SAS expander card end
Figure 10. Flash SAS cable connector color codes - microbay adapter end
Flash SAS cable connector color codes - microbay adapter end

Flash PCIe and SAS cabling tables

Table 7 and Table 8 show a summary of Flash PCIe / SAS cabling for models 984 and 84E.
Table 9 shows details of the Flash PCIe / SAS cabling with Rack 1 high-performance flash enclosures (device adapter pair 18, in normal installation order).
Table 10 shows details of the Flash PCIe / SAS cabling with Rack 2 high-performance flash enclosures (device adapter pair 22, in normal installation order).
Note: Location designators are labeled as link in the following tables.
Table 7. Flash PCIe cabling summary – Rack 1 device adapters (Models 984, 84E)
From
DA pair
DA
Pair (link)
To
Microbay
To
Storage Enclosure
To
Storage Enclosure
R1-XI3-P1-C7-T5
R1-XI4-P1-C7-T6
18 (A)
18 (B)
R1-M04 R1-F03 R1-F04
Table 8. Flash PCIe cabling summary – Rack 2 device adapters (Models 984, 84E)
From
DA pair
DA
Pair (link)
To
Microbay
To
Storage Enclosure
To
Storage Enclosure
R2-XI3-P1-C7-T5
R2-XI4-P1-C7-T6
22 (A)
22 (B)
R2-M04 R2-F03 R2-F04
Table 9. Flash PCIe cabling matrix – DA Pair 18 (Models 984, 84E)
From
DA
link To
Microbay
From
Microbay
link To
Flash enclosure
R1-XI3-P1-C7-T5 18A R1-M04-C1-T7 R1-M04-C1-T1 18A1 R1-F03-P1-C1-T1
R1-M04-C2-T1 18a1 R1-F03-P1-C1-T2
R1-M04-C1-T2 18A2 R1-F03-P1-C2-T1
R1-M04-C2-T2 18a2 R1-F03-P1-C2-T2
R1-XI4-P1-C7-T6 18B R1-M04-C2-T7 R1-M04-C1-T3 18B1 R1-F04-P1-C1-T1
R1-M04-C2-T3 18b1 R1-F04-P1-C1-T2
R1-M04-C1-T4 18B2 R1-F04-P1-C2-T1
R1-M04-C2-T4 18b2 R1-F04-P1-C2-T2
Table 10. Flash PCIe cabling matrix – DA Pair 22 (Models 984, 84E)
From
DA
link To
Microbay
From
Microbay
link To
Flash enclosure
R2-XI3-P1-C7-T5 22A R2-M04-C1-T7 R2-M04-C1-T1 22A1 R2-F03-P1-C1-T1
R2-M04-C2-T1 22a1 R2-F03-P1-C1-T2
R2-M04-C1-T2 22A2 R2-F03-P1-C2-T1
R2-M04-C2-T2 22a2 R2-F03-P1-C2-T2
R2-XI4-P1-C7-T6 22B R2-M04-C2-T7 R2-M04-C1-T3 22B1 R2-F04-P1-C1-T1
R2-M04-C2-T3 22b1 R2-F04-P1-C1-T2
R2-M04-C1-T4 22B2 R2-F04-P1-C2-T1
R2-M04-C2-T4 22b2 R2-F04-P1-C2-T2