These tables show the point-to-point connections for Flash PCIe / SAS
cables on a Model 984 all-flash.
Note:
Racks are shown with the maximum number of storage enclosures and device adapter cards. Your
rack might contain fewer storage enclosures or device adapter cards.
The figures that follow show the maximum number of racks in a storage facility with these rack
models.
Figure 1. Point-to-point cabling diagram for storage enclosure Flash PCIe / SAS cables (Model 984
all-flash, rear view, rack 1)
Flash PCIe cables
Flash PCIe cables and connectors are identified with a colored band matching the DA pair and two
different color codes:
A colored band, corresponding to the color code of the DA pair, is found on each end of the
cable near the connector. These color codes are shown in Figure 1.
The connector is color-coded to help prevent cross-cabling at the microbay adapter card or I/O
enclosure PCIe and PCN card end. Connectors on cables attaching to Rx-Mxx-C1-T7 have white labels
with black text, and connectors on cables attaching to Rx-Mxx-C2-T7 have black labels with white
text. An example of this showing both cables attaching to a microbay adapter card pair is shown in
Figure 2. This alternating color
scheme is the same for all Flash PCIe cables, and is independent of the DA pair color code. Figure 3 and Figure 4 show the Flash PCIe cable
connection ends.
The black and white label at each end has a physical location code showing the "FROM" and "TO" end.
If the cable connects to an I/O enclosure device adapter card connector, the physical location
code is similar to this example: R1-XI1-P1-C7-T5. Refer to I/O enclosure location codes (Models 98x) (not 983).
SAS cables and connectors are identified with two different color codes and a location designator:
A colored band, corresponding to the color code of the DA pair, is found on each end of the
cable near the connector. These color codes are shown in Figure 1.
The connector itself is color coded to help prevent cross-cabling at the SAS expander card or
device adapter card (DA) end. The connectors always appear in the following
order:
white (T1), green (T2), black (T3), and blue (T4)
as shown in Figure 6 and Figure 7. This color code is
specific to each SAS expander card or DA, and is independent of the DA pair color code.
A black or white label at each end of the cable shows a location designator (for example, 16A1).
Both ends of the cable have the same location designator and DA pair color code. However, the
connector at each end of the same cable usually does NOT have the same color code.
The following alternating color scheme is the same for all Flash SAS cables, and is independent
of the DA pair color code:
Connectors on cables that attach to Rx-Mxx-C1-Tx have white labels with black text.
Connectors on cables that attach to Rx-Mxx-C2-Tx have black labels with white text.
Connectors on cables that attach to Rx-Mxx-C1-Tx have white labels with black text.
Connectors on cables that attach to Rx-Mxx-C2-Tx have black labels with white text.
An example of this showing both ends of two SAS cables to an enclosure is shown in Figure 5.
Location designators are in the form CTP, where:
C
Is the device adapter pair (16-23).
T
Is the port pair on the device adapter (A, B, a, b) (uppercase for left device adapter in pair,
lowercase for right device adapter in pair).
P
Is the logical position of the downstream SAS expander card.
Example: 16a1 is the link between device adapter R1-M02-C2-T1 and R1-F01-P1-C1-T2.
16
Device adapter pair 16
a
First port pair on right adapter of device adapter pair (lowercase a)
1
First SAS expander card
The colored connector band plugged into R1-M02-C2-T1 (16a1) is white, while the colored
connector band plugged into R1-F01-P1-C1-T2 (16a1) is green.
The black and white label at each end may have a physical location code in addition to the
location designator.
Figure 5. Flash SAS cable connector example. Two cables shown. Actual values might not match this machine model.Figure 6. Flash SAS cable connector color codes - SAS expander card endFigure 7. Flash SAS cable connector color codes - microbay adapter end
Flash PCIe and SAS cabling tables
Table 1 shows a summary of
Flash PCIe / SAS cabling for model 984 all-flash.
Table 2 through Table 5 show details of the Flash PCIe
/ SAS cabling with Rack 1 high-performance flash enclosures (device adapter pair 16, 17, 18, and 19,
in normal installation order).
Note: Location designators are labeled as link in the following tables.