| Error code | Message | Recovery action |
|---|---|---|
| 0201 | Service Processor command failed after {0} attempts: Invalid response. | Wait several minutes and try the task again. |
| 0203 | Command sent to Service Processor failed. Error response {0}. |
|
| 0204 | Command failed. Unknown error. |
|
| 0205 | The managed system is in the error state and is unable to continue with the task. | The recovery partition data task cannot be run
until the managed system is no longer in error state.
|
| 0206 | Failed to power on the managed system. Unable to continue with the power on task. |
|
| 0208 | Failed to power on the managed system. Could not continue with the power on task. |
|
| 0209 | Remote virtual terminal sessions are not allowed. Check the remote virtual terminal settings. | Virtual terminal cannot open remotely at this time. If this feature is needed, use the Enable/Disable Remote Virtual Terminal task in the System Configuration menu to enable remote connections. |
| 020A | The power on system profile operation timed out. Activate the system profile manually after the managed system is powered on. | Activate the system profile manually after the managed system is powered on. |
| 020D | The command you issued contained incorrect data. | Contact IBM support. |
| 0211 | The requested function is currently disabled. | Shut down the managed system, and start it again. |
| 0212 | The managed system is not Capacity on Demand (CoD) capable at the present time. |
|
| 0213 | The managed system does not support Capacity on Demand upgrades for processors. | Contact your local representative for more information about this feature. |
| 0214 | The managed system does not support Capacity on Demand upgrades for memory. | Contact your local representative for more information about this feature. |
| 0215 | There was an error trying to save processor order information to a diskette. | Verify that the diskette is writable, and retry the operation again. If the error persists, contact your next level of support. |
| 0222 | The operation cannot be done because the managed system is not LPAR capable. |
|
| 0223 | Firmware is not ready to accept the specified command. Try again later. |
|
| 0224 | There was an error dumping the LPAR configuration. Please check the console event log. |
|
| 0225 | There was an error clearing the LPAR configuration. Please check the console event log. |
|
| 0226 | Invalid firmware power off policy returned from the service processor. Unable to determine whether the firmware should power off or stay running after last partition powers off. |
|
| 0228 | The managed system could not be found in the database. Perform a rebuild managed system operation, and try again. |
|
| 0229 | Memory specified, {0}, is not a multiple of the system memory region size, {1}. Please modify the value to be a multiple of the memory region size and try again. |
|
| 022A | The operation cannot be done since the managed system is not OS/400 capable. |
|
| 022C | The managed system is not in a valid state to perform the operation. Check the state of the managed system and retry the operation. |
|
| 022D | Unable to perform a get or a set operation on the managed system's platform IPL parameters. |
|
| 022E | Unable to restore the profile data when the managed system is not in the Operating or Standby state. |
|
| 022F | Unable to delete the profile data backup file, {0}. |
|
| 0230 | Unable to get managed system credential information. |
|
| 0231 | Unable to set managed system credential information. |
|
| 0233 | Unable to change the service partition to the partition with ID of {0}. Please check your current setting(s) and ensure this change is allowed. | The service partition is not able to be changed.
|
| 0234 | Failed to transition out of standby state. Rebuild the managed system and try again. |
|
| 0235 | Cannot change service partition from one partition to another if either one of them are not in the Not Activated state. |
|
| 0236 | The name specified contain unprintable or invalid characters listed: {0}. Remove the invalid characters and try again. |
|
| 0240 | The {0} password is locked and cannot be changed while it is locked. | The password has been locked, contact your hardware service provider to unlock the password. |
| 0241 | The {0} password is locked. | The password has been locked, contact your hardware service provider to unlock the password. |
| 0250 | The managed system MTMS is empty. | |
| 0251 | Service processor command {0} failed. The connection to the hardware server is broken. | Ensure the network connection is working. If the problem persists, contact your next level of support. |
| 0252 | Service processor command {0} failed. The connection to service processor is not available. | Ensure the network connection is working. If the problem persists, contact your next level of support. |
| 0253 | Service processor command {0} failed. The managed system has been deleted. | Ensure the network connection is working. If the problem persists, contact your next level of support. |
| 0254 | Hardware server command {0} failed. No response package. |
|
| 0255 | Hardware server command {0} failed. The request ID has been deleted from the ID table. |
|
| 0256 | Issuing a service processor pass through failed. management console server is trying to reconnect to the hardware server. |
|
| 0257 | Issuing a service processor pass through failed. management console server reestablished a connection to the hardware server after this command was issued. |
|
| 0258 | Issuing a service processor pass through failed. An expected exception with message {0} was thrown. |
|
| 0259 | Service processor lock failed. The lock manager is not active. | Restart the management console. If the problem persists, contact your next level of support. |
| 025A | Service processor lock failed. The conflict lock is owned by management console: {0}. Its request ID is {1}. |
|
| 025B | Query service processor data failed. The error code is {0}. | |
| 025C | Service processor command {0} failed. Service processor authentication needs to be done first. |
|
| 025D | Service processor command {0} failed. System firmware is not ready to accept command. |
|
| 025E | The lock table in the managed system is full. Please try again. | Wait and then try the operation again. |
| 025F | There is a managed system lock. | Wait and then try the operation again. |
| 0260 | Unexpected error happened when trying to acquire a managed system lock. The command return status is {0}. | Wait and then try the operation again. |
| 0261 | Unexpected error happened when trying to acquire a managed system lock. | Report the problem to your next level of support. |
| 0262 | Supplement lock operation is failed. | Check the input and permission and try the task again. |
| 0263 | Service processor does not support more than one management console connection. No Service processor lock is needed. | Contact your next level of support. |
| 0264 | The console command manager is not active. |
|
| 0265 | No destination was specified for command {0}. The command cannot be sent. |
|
| 0266 | The request to query data on the managed system failed with error code {0}. |
|
| 0267 | The connection to the service processor has been lost. A long-running task was stopped. | Verify the completion of the long-running task. If the task did not complete successfully, try the task again |
| 0268 | An unexpected error occurred in a long-running task. | Verify the completion of the long-running task. If the task did not complete successfully, try the task again. |
| 0269 | Managed system with IP address {0} cannot be found. | Verify the specified IP address. Specify a valid IP address and try the request again. |
| 026A | The specified managed system name {0} is not valid with the specified IP address {1}. The managed system cannot be removed. | Specify a valid managed system name and a valid IP address. Then try the request again. |
| 026B | Cannot find a managed system with the specified name {0}. | Verify the specified system name. Specify a valid managed system name and try the request again. |
| 026C | The request to add a new managed system with IP address {0} failed. | Verify the specified IP address. Specify a valid IP address and try the request again. |
| 026D | Lock type {0} is not valid for the managed system. |
|
| 026E | The lock manager for managed system {0} is not active. | Try the request again later. If the problem persists, contact your service provider. |
| 026F | Either the managed system name or the IP address is not specified in the request to remove the managed system. | Specify both the managed system name and the IP address. Then try the request again. |
| 0270 | The specified command destination {0} cannot be found. The command {1} cannot be sent. |
|
| 0271 | The connection state of the specified command destination {0} is not valid. The command {1} cannot be sent. | The connection to the managed system has been lost. Try the request again later. |
| 0280 | The service processor managed system state is not valid. The power state is {0}. The run state is {1}. |
|
| 0281 | The operation cannot be done because the managed system is not shared processor capable. | No recovery action is required. |
| 0282 | The virtual Ethernet adapter in virtual I/O slot {0} cannot be defined because the partition with ID {1} already defines a trunk adapter in its virtual I/O slot {2}. Please modify the profile accordingly and reactivate the partition. | Please modify the profile accordingly and reactivate the partition. |