Before you begin
These settings are documented under the HMC option HMC network settings
in the
section Configuring the customer network settings.Attention: Do not connect
the Ethernet cable until you have entered the network settings that are provided by the
customer.
Procedure
-
Have you already set the customer Ethernet connection settings?
- No, skip this step. Go to the next step.
- Yes, do the following to route and connect the customer Ethernet cables to the management
console (or to both management consoles, as required).
-
Locate the customer-supplied Ethernet cables.
-
Ensure that each cable is routed between the customer Ethernet connector and the system you are
installing.
-
Ensure that the customer end of each cable is connected to the customer network port.
-
Route each cable to rear of the management enclosure cable management arm. Secure each cable as
appropriate for the rack used.
-
Connect each cable to the customer Ethernet port connector at the rear of the cable management
arm. See Table 1.
Table 1. Management console customer network
connections
| Network connection |
Management console port |
Cable label |
| MC 1 (primary management console) customer network |
eth2 |
MC1-A or HMC1-eth2 |
| MC 2 (secondary management console) customer network |
eth2 |
MC2-A or HMC2-eth2 |
| MC 1 second customer LAN (if used) (see Note 1.e.i) |
eth1 |
MC1-B or HMC1-eth1 |
| MC 2 second customer LAN (if used) (see Note 1.e.i) |
eth1 |
MC2-B or HMC2-eth1 |
Notes:
- This connection is by RPQ only. In all other cases, the cable is present but not
connected.
|
-
Continue with Powering on and verifying the storage facility.