PWR1916

The system power control network (SPCN) identifier might be set incorrectly.

PWR1916 Section-1

Before you begin

Note: Storage complex repair actions must always be managed from the management console. To replace any FRUs identified in this procedure, use Storage Facility Management > storage facility > Exchange Parts. If the FRUs are listed in this or another Serviceable Event, select them from there.

Procedure

  1. Launch an ASM session on the failing service processor card. Use Storage Facility Management > storage facility > Server View > server > Operations > Launch Advanced System Management (ASM).
  2. Log on to ASM. Use the userid celogin. Contact your support center for the required password.
  3. Open System Configuration and select Configure I/O Enclosures.
  4. Check the Power Control Network Identifiers for the CEC and I/O enclosures. The CEC enclosure should be set to 0xB6 and all I/O enclosures should be set to 0x88. For an example of the display, see Table 1.
    Table 1. Example display for the power control network identifiers
    Rack address Unit address Power Control Network Identifier Power Control Network Firmware Update Status Power Control Network Firmware Version Start Time Type - Model Serial Number Location code
    0x3C00 0x1 0xE0 Not Applicable     789D-001 DQD84C4 U789D.001.DQD84C4
    0x3C09 0x1 0xC3 Not Required 00PCI022309a   1400-1B2 FK84012 U1400.1B2.FK84012
    0x3C0A 0x1 0xC3 Not Required 00PCI022309a   1400-1B4 FK84014 U1400.1B4.FK84014
    0x3C0C 0x1 0xC3 Not Required 00PCI022309a   1400-2B4 ABC1234 U1400.2B4.ABC1234
    0x3C0B 0x1 0xC3 Not Required 00PCI022309a   1400-2B2 TUVWXYZ U1400.2B2.TUVWXYZ
  5. Were the power control network identifiers set correctly?
    • Yes, continue with the next step.
    • No, update the values using the ASM menu selections and continue with the next step.
  6. Retry the operation that failed. If the problem persists, go to the appropriate procedure: