Power distribution cables, Models 951, 95E

Use the cabling diagram to route power distribution unit (PDU) cables in Models 951, 95E.

Figure 1. Locations for power distribution units
Locations for power distribution units
Figure 2. Locations for power distribution unit (PDU) connectors
Locations for power distribution unit (PDU) connectors
Table 1 and Table 2 show power cables between the power distribution units (PDUs), primary power supply (PPS) modules, and bus bars.
Table 3, Table 4, and Table 5 show power cables between the PDUs and the CEC enclosure, I/O enclosure, and storage enclosure power supplies.
Table 1. PDU to PPS and bus bar cabling - Racks 1 and 2 (Models 951, 95E)
PDU port connects to connection description P/N FRU/PN PDU group
Note: For further guidance on the connects to locations in this table, refer to Rack power and cooling location codes (Models 951, 95E).
E21-J9 E1-E3-J1 PPS E1 (upper), right 208V module 45W5369 45W8802 yellow
E21-J10 E23-J10 PDU E23 45W8173 45W8804 yellow
E22-J9 E2-E1-J1 PPS E2 (lower), left 208V module 45W5370 45W8801 green
E22-J10 E24-J10 PDU E24 45W8174 45W8803 green
E23-J9 E2-E3-J1 PPS E2 (lower), right 208V module 45W5368 45W8802 yellow
E23-J10 E21-J10 PDU E21 45W8173 45W8804 yellow
E24-J9 E1-E1-J1 PPS E1 (upper), left 208V module 45W5371 45W8801 green
E24-J10 E22-J10 PDU E22 45W8174 45W8803 green
E25-J9 bus bar A1 primary bus bar A (longer) 45W5367 45W8804 yellow
E25-J10   not used      
E26-J9 bus bar B1 primary bus bar B (shorter) 45W5366 45W8803 green
E26-J10   not used      
Table 2. PDU to PPS and bus bar cabling - Racks 3 and 4 (Models 951, 95E)
PDU port connects to connection description P/N FRU/PN PDU group
Note: For further guidance on the connects to locations in this table, refer to Rack power and cooling location codes (Models 951, 95E).
E21-J9 E2-E3-J1 PPS E2 (lower), right 208V module 45W8176 45W8802 yellow
E21-J10 E23-J10, E25-J10 PDU E23, PDU E25 45W8450 45W8450 yellow
E22-J9 E1-E3-J1 PPS E1 (upper), right 208V module 45W8175 45W8801 green
E22-J10 E24-J10, E26-J10 PDU E24, PDU E26 45W8447 45W8447 green
E23-J9 E2-E1-J1 PPS E2 (lower), left 208V module 45W9653 45W8802 yellow
E23-J10 E21-J10, E25-J10 PDU E21, PDU E25 45W8450 45W8450 yellow
E24-J9 E1-E1-J1 PPS E1 (upper), left 208V module 45W5371 45W8801 green
E24-J10 E22-J10, E26-J10 PDU E22, PDU E26 45W8447 45W8447 green
E25-J9 bus bar A1 primary bus bar A (longer) 45W5367 45W8804 yellow
E25-J10 E21-J10, E23-J10 PDU E21, PDU E23 45W8450 45W8450 yellow
E26-J9 bus bar B1 primary bus bar B (shorter) 45W5366 45W8803 green
E26-J10 E22-J10, E24-J10 PDU E22, PDU E24 45W8447 45W8447 green
Table 3. PDU to CEC, I/O, and storage enclosure cabling - Rack 1 (Models 951, 95E)
PDU port connects to connection description P/N FRU/PN PDU group
PDU E21
E21-J1 G01-E2 storage enclosure G01 PSU E2 (right) 45W9127 45W8809 yellow
E21-J2 G02-E2 storage enclosure G02 PSU E2 (right) 45W9127 45W8809 yellow
E21-J3 G03-E2 storage enclosure G03 PSU E2 (right) 45W9127 45W8809 yellow
E21-J4 G04-E2 storage enclosure G04 PSU E2 (right) 45W9127 45W8809 yellow
E21-J5 G05-E2 storage enclosure G05 PSU E2 (right) 45W9127 45W8809 yellow
E21-J6   not used      
E21-J7   not used      
E21-J8   not used      
PDU E22
E22-J1 G01-E1 storage enclosure G01 PSU E1 (left) 45W9128 45W8810 green
E22-J2 G02-E1 storage enclosure G02 PSU E1 (left) 45W9128 45W8810 green
E22-J3 G03-E1 storage enclosure G03 PSU E1 (left) 45W9128 45W8810 green
E22-J4 G04-E1 storage enclosure G04 PSU E1 (left) 45W9128 45W8810 green
E22-J5 G05-E1 storage enclosure G05 PSU E1 (left) 45W9128 45W8810 green
E22-J6   not used      
E22-J7   not used      
E22-J8   not used      
PDU E23
E23-J1 G06-E2 storage enclosure G06 PSU E2 (right) 45W9127 45W8809 yellow
E23-J2 G07-E2 storage enclosure G07 PSU E2 (right) 45W9127 45W8809 yellow
E23-J3 G08-E2 storage enclosure G08 PSU E2 (right) 45W9127 45W8809 yellow
E23-J4 G09-E2 storage enclosure G09 PSU E2 (right) 45W9127 45W8809 yellow
E23-J5 G10-E2 storage enclosure G10 PSU E2 (right) 45W9127 45W8809 yellow
E23-J6   not used      
E23-J7   not used      
E23-J8   not used      
PDU E24
E24-J1 G06-E1 storage enclosure G06 PSU E1 (left) 45W9128 45W8810 green
E24-J2 G07-E1 storage enclosure G07 PSU E1 (left) 45W9128 45W8810 green
E24-J3 G08-E1 storage enclosure G08 PSU E1 (left) 45W9128 45W8810 green
E24-J4 G09-E1 storage enclosure G09 PSU E1 (left) 45W9128 45W8810 green
E24-J5 G10-E1 storage enclosure G10 PSU E1 (left) 45W9128 45W8810 green
E24-J6   not used      
E24-J7   not used      
E24-J8   not used      
PDU E25
E25-J1 XC1-E2 upper CEC, power supply E2 (right) 45W5216 45W8807 yellow
E25-J2 XC2-E2 lower CEC, power supply E2 (right) 45W5216 45W8807 yellow
E25-J3   not used      
E25-J4   not used      
E25-J5 XI2-E1 front upper left I/O, power supply E1 (left) 45W7925 45W8807 yellow
E25-J6 XI1-E1 front upper right I/O, power supply E1 (left) 45W7926 45W8807 yellow
E25-J7 XI4-E1 front lower left I/O, power supply E1 (left) 45W7925 45W8807 yellow
E25-J8 XI3-E1 front lower right I/O, power supply E1 (left) 45W7926 45W8807 yellow
PDU E26
E26-J1 XC1-E1 upper CEC, power supply E1 (left) 45W5217 45W8808 green
E26-J2 XC2-E1 lower CEC, power supply E1 (left) 45W5217 45W8808 green
E26-J3   not used      
E26-J4   not used      
E26-J5 XI2-E2 front upper left I/O, power supply E2 (right) 45W7924 45W8808 green
E26-J6 XI1-E2 front upper right I/O, power supply E2 (right) 45W7927 45W8808 green
E26-J7 XI4-E2 front lower left I/O, power supply E2 (right) 45W7924 45W8808 green
E26-J8 XI3-E2 front lower right I/O, power supply E2 (right) 45W7927 45W8808 green
Table 4. PDU to I/O and storage enclosure cabling - Rack 2 (Models 951, 95E)
PDU port connects to connection description P/N FRU/PN PDU group
Note: For further guidance on the connects to locations in this table, refer to:
PDU E21
E21-J1 G01-E2 storage enclosure G01 PSU E2 (right) 45W9127 45W8809 yellow
E21-J2 G02-E2 storage enclosure G02 PSU E2 (right) 45W9127 45W8809 yellow
E21-J3 G03-E2 storage enclosure G03 PSU E2 (right) 45W9127 45W8809 yellow
E21-J4 G04-E2 storage enclosure G04 PSU E2 (right) 45W9127 45W8809 yellow
E21-J5 G05-E2 storage enclosure G05 PSU E2 (right) 45W9127 45W8809 yellow
E21-J6 G06-E2 storage enclosure G06 PSU E2 (right) 45W9127 45W8809 yellow
E21-J7 G07-E2 storage enclosure G07 PSU E2 (right) 45W9127 45W8809 yellow
E21-J8   not used      
PDU E22
E22-J1 G01-E1 storage enclosure G01 PSU E1 (left) 45W9128 45W8810 green
E22-J2 G02-E1 storage enclosure G02 PSU E1 (left) 45W9128 45W8810 green
E22-J3 G03-E1 storage enclosure G03 PSU E1 (left) 45W9128 45W8810 green
E22-J4 G04-E1 storage enclosure G04 PSU E1 (left) 45W9128 45W8810 green
E22-J5 G05-E1 storage enclosure G05 PSU E1 (left) 45W9128 45W8810 green
E22-J6 G06-E1 storage enclosure G06 PSU E1 (left) 45W9128 45W8810 green
E22-J7 G07-E1 storage enclosure G07 PSU E1 (left) 45W9128 45W8810 green
E22-J8   not used      
PDU E23
E23-J1 G08-E2 storage enclosure G08 PSU E2 (right) 45W9127 45W8809 yellow
E23-J2 G09-E2 storage enclosure G09 PSU E2 (right) 45W9127 45W8809 yellow
E23-J3 G10-E2 storage enclosure G10 PSU E2 (right) 45W9127 45W8809 yellow
E23-J4 G11-E2 storage enclosure G11 PSU E2 (right) 45W9127 45W8809 yellow
E23-J5 G12-E2 storage enclosure G12 PSU E2 (right) 45W9127 45W8809 yellow
E23-J6 G13-E2 storage enclosure G13 PSU E2 (right) 45W9127 45W8809 yellow
E23-J7 G14-E2 storage enclosure G14 PSU E2 (right) 45W9127 45W8809 yellow
E23-J8   not used      
PDU E24
E24-J1 G08-E1 storage enclosure G08 PSU E1 (left) 45W9128 45W8810 green
E24-J2 G09-E1 storage enclosure G09 PSU E1 (left) 45W9128 45W8810 green
E24-J3 G10-E1 storage enclosure G10 PSU E1 (left) 45W9128 45W8810 green
E24-J4 G11-E1 storage enclosure G11 PSU E1 (left) 45W9128 45W8810 green
E24-J5 G12-E1 storage enclosure G12 PSU E1 (left) 45W9128 45W8810 green
E24-J6 G13-E1 storage enclosure G13 PSU E1 (left) 45W9128 45W8810 green
E24-J7 G14-E1 storage enclosure G14 PSU E1 (left) 45W9128 45W8810 green
E24-J8   not used      
PDU E25
E25-J1   not used      
E25-J2   not used      
E25-J3   not used      
E25-J4   not used      
E25-J5 XI2-E1 front upper left I/O, power supply E1 (left) 45W7925 45W8807 yellow
E25-J6 XI1-E1 front upper right I/O, power supply E1 (left) 45W7926 45W8807 yellow
E25-J7 XI4-E1 front lower left I/O, power supply E1 (left) 45W7925 45W8807 yellow
E25-J8 XI3-E1 front lower right I/O, power supply E1 (left) 45W7926 45W8807 yellow
PDU E26
E26-J1   not used      
E26-J2   not used      
E26-J3   not used      
E26-J4   not used      
E26-J5 XI2-E2 front upper left I/O, power supply E2 (right) 45W7924 45W8808 green
E26-J6 XI1-E2 front upper right I/O, power supply E2 (right) 45W7927 45W8808 green
E26-J7 XI4-E2 front lower left I/O, power supply E2 (right) 45W7924 45W8808 green
E26-J8 XI3-E2 front lower right I/O, power supply E2 (right) 45W7927 45W8808 green
Table 5. PDU to storage enclosure cabling - Racks 3 and 4 (Models 951, 95E)
PDU port connects to connection description P/N FRU P/N PDU group
Note: For further guidance on the connects to locations in this table, refer to Storage enclosure location codes (Models 951, 95E).
PDU E21
E21-J1 G01-E2 storage enclosure G01 PSU E2 (right) 45W9127 45W8809 yellow
E21-J2 G02-E2 storage enclosure G02 PSU E2 (right) 45W9127 45W8809 yellow
E21-J3 G03-E2 storage enclosure G03 PSU E2 (right) 45W9127 45W8809 yellow
E21-J4 G04-E2 storage enclosure G04 PSU E2 (right) 45W9127 45W8809 yellow
E21-J5 G05-E2 storage enclosure G05 PSU E2 (right) 45W9127 45W8809 yellow
E21-J6 G06-E2 storage enclosure G06 PSU E2 (right) 45W9127 45W8809 yellow
E21-J7 G07-E2 storage enclosure G07 PSU E2 (right) 45W9127 45W8809 yellow
E21-J8   not used      
PDU E22
E22-J1 G01-E1 storage enclosure G01 PSU E1 (left) 45W9128 45W8810 green
E22-J2 G02-E1 storage enclosure G02 PSU E1 (left) 45W9128 45W8810 green
E22-J3 G03-E1 storage enclosure G03 PSU E1 (left) 45W9128 45W8810 green
E22-J4 G04-E1 storage enclosure G04 PSU E1 (left) 45W9128 45W8810 green
E22-J5 G05-E1 storage enclosure G05 PSU E1 (left) 45W9128 45W8810 green
E22-J6 G06-E1 storage enclosure G06 PSU E1 (left) 45W9128 45W8810 green
E22-J7 G07-E1 storage enclosure G07 PSU E1 (left) 45W9128 45W8810 green
E22-J8   not used      
PDU E23
E23-J1 G08-E2 storage enclosure G08 PSU E2 (right) 45W9127 45W8809 yellow
E23-J2 G09-E2 storage enclosure G09 PSU E2 (right) 45W9127 45W8809 yellow
E23-J3 G10-E2 storage enclosure G10 PSU E2 (right) 45W9127 45W8809 yellow
E23-J4 G11-E2 storage enclosure G11 PSU E2 (right) 45W9127 45W8809 yellow
E23-J5 G12-E2 storage enclosure G12 PSU E2 (right) 45W9127 45W8809 yellow
E23-J6 G13-E2 storage enclosure G13 PSU E2 (right) 45W9127 45W8809 yellow
E23-J7 G14-E2 storage enclosure G14 PSU E2 (right) 45W9127 45W8809 yellow
E23-J8   not used      
PDU E24
E24-J1 G08-E1 storage enclosure G08 PSU E1 (left) 45W9128 45W8810 green
E24-J2 G09-E1 storage enclosure G09 PSU E1 (left) 45W9128 45W8810 green
E24-J3 G10-E1 storage enclosure G10 PSU E1 (left) 45W9128 45W8810 green
E24-J4 G11-E1 storage enclosure G11 PSU E1 (left) 45W9128 45W8810 green
E24-J5 G12-E1 storage enclosure G12 PSU E1 (left) 45W9128 45W8810 green
E24-J6 G13-E1 storage enclosure G13 PSU E1 (left) 45W9128 45W8810 green
E24-J7 G14-E1 storage enclosure G14 PSU E1 (left) 45W9128 45W8810 green
E24-J8   not used      
PDU E25
E25-J1 G15-E2 storage enclosure G15 PSU E2 (right) 45W9127 45W8809 yellow
E25-J2 G16-E2 storage enclosure G16 PSU E2 (right) 45W9127 45W8809 yellow
E25-J3 G17-E2 storage enclosure G17 PSU E2 (right) 45W9127 45W8809 yellow
E25-J4 G18-E2 storage enclosure G18 PSU E2 (right) 45W9127 45W8809 yellow
E25-J5 G19-E2 storage enclosure G19 PSU E2 (right) 45W9127 45W8809 yellow
E25-J6 G20-E2 storage enclosure G20 PSU E2 (right) 45W9127 45W8809 yellow
E25-J7   not used      
E25-J8   not used      
PDU E26
E26-J1 G15-E1 storage enclosure G15 PSU E1 (left) 45W9128 45W8810 green
E26-J2 G16-E1 storage enclosure G16 PSU E1 (left) 45W9128 45W8810 green
E26-J3 G17-E1 storage enclosure G17 PSU E1 (left) 45W9128 45W8810 green
E26-J4 G18-E1 storage enclosure G18 PSU E1 (left) 45W9128 45W8810 green
E26-J5 G19-E1 storage enclosure G19 PSU E1 (left) 45W9128 45W8810 green
E26-J6 G20-E1 storage enclosure G20 PSU E1 (left)
45W9128 45W8810 green
E26-J7   not used      