Exchange the PPS fan
Before you begin
Use approved ESD procedures to prevent damage.
Attention:
- This procedure is not a stand-alone procedure. Customer disruption and damage to the hardware might occur when microcode and power boundaries are not in the proper conditions for this service action.
- If a serviceable event FRU repair directed you to this procedure, the microcode and power boundaries are already set.
- If a serviceable event FRU repair did not direct you to this procedure, see MAP1230 Replace a FRU without using a serviceable event.
Notes:
- All the cables and FRUs to be removed must be uniquely identified so they can be reinstalled correctly.
- If an installed earthquake resistance kit prevents you from accessing this FRU, refer to MAP1600.
DANGER
Hazardous
voltage, current, or energy levels are present inside of a component
to which this label is attached. (L001)

Remove the PPS fan
Procedure
Install the PPS fan
Procedure
- Install the new PPS fan and
wire finger guard from the old PPS fan using
the two screws
. - Connect the PPS fan cable
to the PPS connector
. See Figure 1. - Exit this service information center parts exchange procedure and return to the procedure that sent you here.