The failing component is the board that the memory DIMMs
plug into.
Before you begin
Note: Storage complex repair actions must always be managed from the
management console. To replace any FRUs identified in this procedure, use . If the FRUs are listed in
this or another Serviceable Event, select them from there.
Procedure
- Select the Model that applies:
- For Models 941, 951, complete steps 2 and 3.
- For Model 961, complete steps 4 and 5.
- If the location
code identifies the CEC enclosure system
processor card that has the problem, replace the system processor
card identified by the location code.
- If no location code
is provided, replace the processor cards. Location codes
Un-P2-C1, Un-P2-C2. Refer to Exchanging parts.
This ends the procedure for Models 941,
951.
- If the
location code identifies the CEC enclosure memory
card that has the problem, replace the memory card identified by the
location code.
- If no location
code is provided, replace the memory cards. Location codes Un-P2-C15,
Un-P2-C16, Un-P2-C17, Un-P2-C18. Refer to Exchanging parts.
This
ends the procedure for Model 961.