(5708xxxx) Reference codes

If the error is reported on the control panel, the unit reference code is characters 5 through 8 of the top 16 character line of function 11. If the error is reported on the console, the unit reference code is the four rightmost characters of the first word.

Find the unit reference code in Table 1. For more on the Failing Item column entries, see Isolation MAPs and symbolic FRU procedures.

Table 1. (5708xxxx) Reference codes
SRC Description/Action Failing Item
57083006 System bus error
57083100 Interface error

Error occurred on SCSI bus 0.

 
57083101 Interface error

Error occurred on SCSI bus 1.

 
57083400 SCSI resource error  
57088008 A permanent cache battery pack failure occurred CACHBAT
57088009 Impending cache battery pack failure CACHBAT
57088130 IOA detected recoverable SCSI bus error

An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only.

 
57088131 IOA detected recoverable SCSI bus error

An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only.

 
57088140 IOA detected recoverable SCSI bus error

No action is required. This reference code is logged for information only.

 
57088141 IOA detected recoverable SCSI bus error

No action is required. This reference code is logged for information only.

 
57088145 A recoverable error occurred  
57088150 A permanent failure occurred ANYBRDG
57088151 Licensed Internal Code error PTFSRCH
57088155 to 57088156 A permanent failure occurred PTFSRCH
57088157 I/O adapter card error
Display the Service Action Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to:
  1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On.
  2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources.
SVCDOCS
57088300 IOA hardware or PCI bus error
57088301 Not valid condition in Licensed Internal Code PTFSRCH
57088302 Missing Licensed Internal Code

Ensure that the code necessary to support this I/O adapter is loaded.

SVCDOCS
57089055 Write cache data is available for attached storage IOA

No service action required.

 
57089071 Link from IOA to auxiliary cache IOA went operational

No service action required.

 
57089072 Link from IOA to auxiliary cache IOA went non-operational

No service action required.

 
57089073 Disconnected, incompatible, or non-operational storage IOA SVCDOCS
5708FF3D I/O adapter detected recoverable error ANYBRDG