(574Fxxxx) Reference codes

If the error is reported on the control panel, the unit reference code is characters 5 - 8 of the top 16 character line of function 11. If the error is reported on the console, the unit reference code is the four rightmost characters of the first word.

Find the unit reference code in Table 1. For more on the Failing Item column entries, see Isolation MAPs and symbolic FRU procedures.

Table 1. (574Fxxxx) Reference codes
SRC Description/Action Failing Item
574F3006 System bus error
574F3100 Interface error

Error occurred on SCSI bus 0.

 
574F3101 Interface error

Error occurred on SCSI bus 1.

 
574F3400 SCSI resource error  
574F8008 A permanent cache battery pack failure occurred CACHBAT
574F8009 Impending cache battery pack failure CACHBAT
574F8130 IOA detected recoverable SCSI bus error.

An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only.

 
574F8131 IOA detected recoverable SCSI bus error.

An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only.

 
574F8140 IOA detected recoverable SCSI bus error.

No action is required. This reference code is logged for information only.

 
574F8141 IOA detected recoverable SCSI bus error.

No action is required. This reference code is logged for information only.

 
574F8145 A recoverable error occurred  
574F8150 A permanent failure occurred ANYBRDG
574F8151 Licensed Internal Code error PTFSRCH
574F8155 to 574F8156 A permanent failure occurred PTFSRCH
574F8157 I/O adapter card error
Display the Service Action Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS , then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to:
  1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On.
  2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources.
SVCDOCS
574F8300 IOA hardware or PCI bus error
574F8301 Not valid condition in Licensed Internal Code PTFSRCH
574F8302 Missing Licensed Internal Code

Ensure that the code necessary to support this I/O adapter is loaded.

SVCDOCS
574F9055 Write cache data is available for attached storage IOA.

No service action required.

 
574F9071 Link from IOA to auxiliary cache IOA went operational.

No service action required.

 
574F9072 Link from IOA to auxiliary cache IOA went non-operational.

No service action required.

 
574F9073 Disconnected, incompatible, or non-operational storage IOA SVCDOCS
574FFF3D I/O adapter detected recoverable error. ANYBRDG