(574Fxxxx) Reference codes
If the error is reported on the control panel, the unit reference code is characters 5 - 8 of the top 16 character line of function 11. If the error is reported on the console, the unit reference code is the four rightmost characters of the first word.
Find the unit reference code in Table 1. For more on the Failing Item column entries, see Isolation MAPs and symbolic FRU procedures.
| SRC | Description/Action | Failing Item |
|---|---|---|
| 574F3006 | System bus error | |
| 574F3100 | Interface error Error occurred on SCSI bus 0. |
|
| 574F3101 | Interface error Error occurred on SCSI bus 1. |
|
| 574F3400 | SCSI resource error | |
| 574F8008 | A permanent cache battery pack failure occurred | CACHBAT |
| 574F8009 | Impending cache battery pack failure | CACHBAT |
| 574F8130 | IOA detected recoverable SCSI bus error. An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. |
|
| 574F8131 | IOA detected recoverable SCSI bus error. An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only. |
|
| 574F8140 | IOA detected recoverable SCSI bus error. No action is required. This reference code is logged for information only. |
|
| 574F8141 | IOA detected recoverable SCSI bus error. No action is required. This reference code is logged for information only. |
|
| 574F8145 | A recoverable error occurred | |
| 574F8150 | A permanent failure occurred | ANYBRDG |
| 574F8151 | Licensed Internal Code error | PTFSRCH |
| 574F8155 to 574F8156 | A permanent failure occurred | PTFSRCH |
| 574F8157 | I/O adapter card error Display the Service Action
Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace
the I/O adapter. If the Failing Item indicates SVCDOCS , then do NOT replace
the I/O adapter. This is a recoverable error. Perform the following for the
I/O processor that the I/O adapter is attached to:
|
SVCDOCS |
| 574F8300 | IOA hardware or PCI bus error | |
| 574F8301 | Not valid condition in Licensed Internal Code | PTFSRCH |
| 574F8302 | Missing Licensed Internal Code Ensure that the code necessary to support this I/O adapter is loaded. |
SVCDOCS |
| 574F9055 | Write cache data is available for attached storage IOA. No service action required. |
|
| 574F9071 | Link from IOA to auxiliary cache IOA went operational. No service action required. |
|
| 574F9072 | Link from IOA to auxiliary cache IOA went non-operational. No service action required. |
|
| 574F9073 | Disconnected, incompatible, or non-operational storage IOA | SVCDOCS |
| 574FFF3D | I/O adapter detected recoverable error. | ANYBRDG |