A70069C7 A70069C7

Explanation

Platform LIC detected an error

Response

Abnormal or unexpected HSL OptiConnect disconnection from a remote system or partition.

The local system or partition disconnected from a remote system or partition due to an unexpected event or failure. Licensed Internal Code will attempt to recover from the error. Intervention at the local or remote system or partition might be required.

Possible causes include time out, hang, or hardware failure. The problem may be with the local system or partition or the remote system or partition. If a complete HSL loop did not exist before this error occurred, the cause of this error might be a failure or power down in an HSL component between the local system or partition and the remote system or partition. Check for SRCs with FRUs that indicate problems with the following:
  • HSL cables
  • The HSL I/Oidge
  • Power in an expansion I/O tower or unit on this loop

On the local system or partition, examine the SAL or serviceable event view. Look for failures on the same loop or with the Network Interface Controller that occurred at approximately the same time as this error.

Examine the remote system or partition for problems. Correct any HSL or NIC problems you find with the remote and local systems or partitions. If you find no problems with either the local or the remote systems or partitions, collect all the PAL information for this failure on both systems. Be sure to record all words in the SRC. Contact your next level of support.

Failing Item