A70069C8 A70069C8
Explanation
Platform LIC detected an errorResponse
Abnormal or unexpected HSL OptiConnect disconnection from a remote system or partition.
- Time out of a critical message
- Licensed Internal Code code / table problem
- Network deadlock detected
- The local system or partition
- The remote system or partition
On the local system or partition, examine the SAL or serviceable event view. Look for HSL failures on the same HSL loop or with the Network Interface Controller that occurred at approximately the same time as this error.
Examine the remote system or partition for problems. On the remote system or partition, examine the SAL or serviceable event view. Look for problems on the same HSL loop or with the Network Interface Controller that occurred at approximately the same time as this error.
Correct any problems you find with the remote and local systems or partitions that happened at approximately the same time and involve HSL Opticonnect or HSL loop components or Network Interface Controllers.
If there are no problems with the remote system or partition and there are no problems with the local system or partition then collect all the Product Activity Log information for this failure on all systems or partitions. Be sure to record all words in the SRCs. Contact your next level of support.