B70069C8 B70069C8

Explanation

Platform LIC detected an error

Response

Abnormal or unexpected HSL OptiConnect disconnection from a remote system or partition. The local system or partition disconnected from a remote system or partition due to an unexpected event or failure. All of the HSL OptiConnect connections on this loop will be in a failed state. Licensed Internal Code will attempt to recover from the error. Intervention at the local or remote system or partition might be required. Possible causes are:
  • Time out of a critical message
  • Licensed Internal Code code / table problem
  • Network deadlock detected
The problem may be with:
  • The local system or partition
  • The remote system or partition
On the local system or partition, examine the SAL or serviceable event view. Look for RIO or HSL failures on the same RIO or HSL loop or with the RIO or HSL controller that occurred at approximately the same time as this error. Examine the remote system or partition for problems. On the remote system or partition, examine the SAL or serviceable event view. Look for problems on the same RIO or HSL loop or with the RIO or HSL controller that occurred at approximately the same time as this error. Correct any problems you find with the remote and local systems or partitions that happened at approximately the same time and involve HSL Opticonnect or RIO or HSL loop components. If there are no problems with the remote system or partition and there are no problems with the local system or partition then collect all the Product Activity Log information for this failure on all systems or partitions. Be sure to record all words in the SRCs. Contact your next level of support.

Problem determination

No action is required.

Failing Item